LD TECHNOLOGY LLC

Matched from indexed company URL: LD TECHNOLOGY, LLC

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30061467873006146787LD TECHNOLOGY LLC1N2026-01-01990 Biscayne Blvd Ofc O-1403 Miami FL US 33132

GUDID Contact Samples#

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDID, Product, Phone table
Source GUDIDProductPhoneEmail
B322A0011SweatC - SweatC device is a medical device for the measurement of galvanic skin response related to the function of the sweat glands.305-379-9900albert.ldteck@gmail.com
B322B0011TM-Oxi System - """Oxi-W system is intended for use: To spot check or monitor Oxygen saturation of arterial hemoglobin (SpO2%) and pulse rate. To analyze the pulse waveform (Photoplethysmography or PTG) provided by the oximeter. It only provides mathematical analysis of the input of the PTG using the first and second derivatives of the PTG values related to the microvascular condition.To analyze the basic rhythms of the NN or RR intervals in heart rate from the PTG, both in the time domain and in the frequency domain (short time 5 minutes). It only provides mathematical analysis of the heart rate variability values related to the autonomic nervous system function."""305-379-9900albert.ldteck@gmail.com

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
1010681261412907K200287BP-BT KioskDXN2020-05-15
1010681137197821K200141Oxi-W SystemMWI2020-04-27
1010681527536797K173696TBL-ABI SystemJOM2017-12-19
1010681164583549K172655Automated ankle brachial pressure index measuring deviceJOM2018-01-11
1010682040920916K160956LD-Oxi systemMWI2016-07-06
1010681523005354K152216SudoCGZO2015-09-24
1010682038478675K143152TM-ABI systemJOM2015-07-22
1010681675046959K140412ANS1 SOFTWAREDXN2014-05-22
1010681283440539K131568SUDO PATHGZO2013-06-28
1010681913087920K130056PATIENT MONITORMWI2013-04-11
1010681564364067K120502PC-60NW FINGERTIP OXIMETERDQA2012-12-07
1010681976762526K113264ELECTRO SENSOR COMPLEX SOFTWARE (ES COMPLEX SOFTWARE)DXN2012-03-02
1010681756778879K103026ELECTRO SENSOR -BODY COMPOSITIONMNW2011-03-29
1010681660425659K102442E.S.O. (ELECTRO SENSOR OXI)DQA2010-09-10
1010682064368418K102166ELECTRO INTERSTITIAL SCANGZO2010-12-10

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
DXN32020-05-15
MWI32020-04-27
JOM32018-01-11
GZO32015-09-24
DQA22012-12-07
MNW12011-03-29

PMN#

SudoC

2015-09-24

LD TECHNOLOGY LLC

GUDID#

LD-EKG - Replacement blood pressure TBL-ABI: The TBL-ABI is indicated for use on adult subjects at risk of having or developing peripheral arterial disease (PAD). TBL-ABI is intended for the rapid measurement of ankle-brachial pressure index (ABPI), or ankle-brachial index (ABI), and pulse volume recording (PVR) / volume plethysmography in adults. It is suitable for use in wound care assessment, for assessing symptomatic PAD, and as a screening device for PAD. It may also be used on patients with venous or arterial ulcers prior to the application of compression therapy. TBL-ABI can be used on patients with unilateral lower limb amputation.

LD TECHNOLOGY, LLC

2024-03-05

TM-Oxi System - """Oxi-W system is intended for use: To spot check or monitor Oxygen saturation of arterial hemoglobin (SpO2%) and pulse rate. To analyze the pulse waveform (Photoplethysmography or PTG) provided by the oximeter. It only provides mathematical analysis of the input of the PTG using the first and second derivatives of the PTG values related to the microvascular condition.To analyze the basic rhythms of the NN or RR intervals in heart rate from the PTG, both in the time domain and in the frequency domain (short time 5 minutes). It only provides mathematical analysis of the heart rate variability values related to the autonomic nervous system function."""

LD TECHNOLOGY, LLC

2019-01-16

ANS1 Software - """ANS1 Software is inetended for use: ANS1 Software is an optional software accessory for use with the following models with datamanagement capabilities: a) TM-Oxi (Oximeter and blood pressure device) and b) SudoPath(Galvanic Skin response) and c) ES-BC (Body Composition Analyzer).When used in combination with TM-Oxi and/or SudoPath, and/or ES-BC devices, the ANS1software uploads the data of the devices, analyzes the data, and then displays the data in ac omputer for enhanced data management.The ANS1 software is intended for use in clinical settings as an aid for health careprofessionals to review, analyze, and evaluate the historical tests results."""

LD TECHNOLOGY, LLC

2024-03-05

TBL-ABI - The TBL-ABI is indicated for use on adult subjects at risk of having or developing peripheral arterial disease (PAD). TBL-ABI is intended for the rapid measurement of ankle-brachial pressure index (ABPI), or ankle-brachial index (ABI), and pulse volume recording (PVR) / volume plethysmography in adults. It is suitable for use in wound care assessment, for assessing symptomatic PAD, and as a screening device for PAD. It may also be used on patients with venous or arterial ulcers prior to the application of compression therapy. TBL-ABI can be used on patients with unilateral lower limb amputation.

LD TECHNOLOGY, LLC

2019-01-16

LD-Oxy - To spot check or monitor Oxygen saturation of arterial hemoglobin (SpO2%) and pulse rate. To analyze the pulse waveform (Photoelectrical Plethysmography or PP) provided by the oximeter. It only provides mathematical analyses of the input of the SpO2 measurement. To analyze the basic rhythms of the NN or RR intervals in heart rate, both in the time domain and in the frequency domain (short time 5 minutes). It only provides mathematical analysis of the input of the heart rate variability. The mathematical analysis of Photoelectrical Plethysmography and HRV ARE NOT intended use for diagnosis. The software provides a visual alarm for the values of the heart rate and/or SpO2 percent out of the normal range and for the bad quality signal transmission. The data are stored in PC in the Backup system of the LD-Oxi software. The device is intended use only for adult subjects (> 20 years old) This Oximeter is intended to be used in spot-checking (5 minutes). The device is intended use in licensed practitioner’s office This device is no intended to be used at home, in hospital or out-of-hospital transport The device is not intended use in support life and not for continuously monitoring The system will be use by practitioner.

LD TECHNOLOGY, LLC

2019-01-16