NEOCOIL

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30063694843006369484NEOCOIL, LLC1N2026-01-01N27 W23910A PAUL RD. Pewaukee WI US 53072

GUDID Contact Samples#

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDID, Product, Phone table
Source GUDIDProductPhoneEmail
0085002893249032ch AIR Open Coil Suite, 3.0T - The 32Ch AIR Open Coil Suite, 3.0T (NeoCoil Ref#: NC139020; GEHC Ref#: M7024RT) is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).+1 (262) 522-6124kate.gonzalez@neocoil.com
0085002893250632ch AIR Open Coil Suite, 1.5T - The 32Ch AIR Open Coil Suite,1.5T (NeoCoil Ref#: NC139021; GEHC Ref#: M7025RT) is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).+1 (262) 522-6124kate.gonzalez@neocoil.com

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
732811177526630K22240716ch Breast Coil / 16ch Breast Coils, 1.5T 16ch Breast Coil, 3.0T 16ch Breast Coil, 1.5T 16ch Breast Coil, 3T 16ch Breast CoilMOS2022-10-14
732812027572987K21368732Ch AIR Open Coil Suite: 1.5T AIR Open Head Neck Posterior 9ch / 3.0T AIR Open Head Neck Posterior 9ch, 1.5T AIR Open Neck Chest Anterior 7ch / 3.0T AIR Open Neck Chest Anterior 7ch, 1.5T AIR Open Head Anterior 16ch / 3.0T AIR Open Head Anterior 16chMOS2022-03-11
732811830206659K2011011.5T 16ch Shoulder Coil, 3.0T 16ch Shoulder CoilMOS2020-06-02
732811684715495K1829581.5T 16ch Breast CoilMOS2018-11-16
732811836136069K173409Wireless Audio SystemLNH2018-02-16
732811053801654K1733773.0T 16ch Breast CoilMOS2017-11-28
732811933064032K160350ECG CT Gating DeviceJAK2016-06-16
732811633258184K1418323T 16CH FLEX SPEEDER, MEDIUM , 3T 16CH FLEX SPEEDER, LARGEMOS2014-07-31
732811435422858K133670HEADPHONES, PATIENT ALERT, STANDALONE INTERFACELNH2014-07-24
732811079302054K1334221.5T 16-CHANNEL FLEX COIL, SMALL 1.5T 16-CHANNEL FLEX COIL, LARGEMOS2013-12-26
732811480927796K1232721.5T 16CH FLEX SPEEDER LARGE, 1.5T 16CH FLEX SPEEDER MEDIUMMOS2013-03-28
732811467798926K1213621.5T 16CH FLEX SPEEDER LARGEMOS2012-06-15
732811046181158K1134741.5T GEM FLEX COILMOS2012-03-16
732811204429097K1033423.0T METAFLEXCOILMOS2010-12-23
732811533361097K101632METAFLEXCOILMOS2010-08-24
732811117950521K073236NEOCOIL 3.0T 32-CHANNEL TORSO ARRAY COIL FOR GEMOS2007-11-30
732811799510351K071611NEOCOIL 3.0T 8-CHANNEL SHOULDER ARRAY COILMOS2007-06-28
732811262311258K071311NEOCOIL 1.5T 8-CHANNEL SHOULDER ARRAY COILMOS2007-05-22
732811708388260K070778NEOCOIL 3.0T 6-CHANNEL CAROTID ARRAY COILMOS2007-04-11
732811236168887
732811962176774

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
MOS162022-10-14
LNH22018-02-16
JAK12016-06-16

PMN#

GUDID#

32ch AIR Open Coil Suite, 1.5T - The 32Ch AIR Open Coil Suite,1.5T (NeoCoil Ref#: NC139021; GEHC Ref#: M7025RT) is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

32ch AIR Open Coil Suite, 3.0T - The 32Ch AIR Open Coil Suite, 3.0T (NeoCoil Ref#: NC139020; GEHC Ref#: M7024RT) is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

3.0T 16ch Shoulder Coil (System) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2020-07-17

1.5T 16ch Shoulder Coil (System) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2020-09-09

1.5T AIR Open Head Anterior 16ch - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

1.5T AIR Open Neck Chest Anterior 7ch - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

1.5T AIR Open Head Neck Posterior 9ch - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

3.0T AIR Open Head Anterior 16ch - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

3.0T AIR Open Neck Chest Anterior 7ch - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

3.0T AIR Open Head Neck Posterior 9ch - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

ECG CT Gating Cable - The SynChron™ Wireless Vector Gating System for CT is a product used to acquire electrocardiogram (ECG) data from a patient and to generate and supply ECG waveform and triggering pulses to the CT scanner to aid in cardiac scanning. The SynChron™ Wireless Vector Gating System for CT includes a Physiologic Acquisition Module (PAM) that connects to the patient using ECG lead wires (Figure 2-2), acquires ECG data, processes the ECG data, and wirelessly transmits the data to the Receive Interface Module (RIM). The RIM will wirelessly receive data from the PAM, create analog ECG waveform and trigger pulse mark, and interfaces with the scanner. The ECG waveform and trigger marks can be seen on the scanner console.

NEOCOIL, LLC

2017-03-21

ECG CT Gating Receiver - The SynChron™ Wireless Vector Gating System for CT is a product used to acquire electrocardiogram (ECG) data from a patient and to generate and supply ECG waveform and triggering pulses to the CT scanner to aid in cardiac scanning. The SynChron™ Wireless Vector Gating System for CT includes a Physiologic Acquisition Module (PAM) that connects to the patient using ECG lead wires (Figure 2-2), acquires ECG data, processes the ECG data, and wirelessly transmits the data to the Receive Interface Module (RIM). The RIM will wirelessly receive data from the PAM, create analog ECG waveform and trigger pulse mark, and interfaces with the scanner. The ECG waveform and trigger marks can be seen on the scanner console.

NEOCOIL, LLC

2017-03-21

ECG CT Gating Device - The SynChron™ Wireless Vector Gating System for CT is a product used to acquire electrocardiogram (ECG) data from a patient and to generate and supply ECG waveform and triggering pulses to the CT scanner to aid in cardiac scanning. The SynChron™ Wireless Vector Gating System for CT includes a Physiologic Acquisition Module (PAM) that connects to the patient using ECG lead wires (Figure 2-2), acquires ECG data, processes the ECG data, and wirelessly transmits the data to the Receive Interface Module (RIM). The RIM will wirelessly receive data from the PAM, create analog ECG waveform and trigger pulse mark, and interfaces with the scanner. The ECG waveform and trigger marks can be seen on the scanner console.

NEOCOIL, LLC

2017-03-21

16ch Shoulder Coil, Replacement Pad Kit (FRU) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

1.5T 16ch Shoulder Coil (FRU) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

3.0T 16ch Shoulder Coil (FRU) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

1.5T 16ch Shoulder Coil (Device) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniformcoverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receivesmagnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magneticfield applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRIscanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

3.0T 16ch Shoulder Coil (Device) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2020-12-30

80 records. Showing 1-40. Next