NELSON ENVIRONMENTAL TECHNOLOGIES, INC.

Matched from indexed company URL: Nelson Environmental Technologies Inc

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
16514343003043063NELSON ENVIRONMENTAL TECHNOLOGIES, INC.1N2026-01-01813 E. FIR Mc Allen TX US 78501
30108668953010866895NELSON ENVIRONMENTAL TECHNOLOGIES, INC.1N2026-01-0110518 Cash Rd. Stafford TX US 77477
30108676483010867648NELSON ENVIRONMENTAL TECHNOLOGIES, INC.1N2026-01-011312 Corporate Dr. E Suite F Arlington TX US 76006

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
783301749913037K993877NELSON WATER SYSTEMS FOR HEMODIALYSISFIP2000-05-25
1709801749913037K993877NELSON WATER SYSTEMS FOR HEMODIALYSISFIP2000-05-25
1710711749913037K993877NELSON WATER SYSTEMS FOR HEMODIALYSISFIP2000-05-25
1709801975133340K193169Nelson Sentinel Series Basic Chlorine SentinelMSY2020-10-29

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
FIP32000-05-25
MSY12020-10-29

PMN#

GUDID#

Chlorine Sentinel II - Chlorine Sentinel II is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. It detects dissolved combined chlorine in concentrations at or above 10 PPB by primary detection technology. It self-monitors for maintenance-required conditions and loss of electrical power. The Chlorine Sentinel II is self-testing. It uses chlorinated city water to automatically test the chlorine detecting functionality of the device once a day and records if the test passed, failed to detect chlorine, or didn’t rinse out after detecting chlorine.The device is designed to use as little water as possible. The sampling water is only used for the length of time that it takes for the chlorine test to be completed. The customer determines how frequently the test needs to be taken from every 5 minutes to every 20 minutes. The user also sets the start time and end time for each day of the week.The Chlorine Sentinel II has two combined chlorine concentration set points. The user can set a warning set-point at a value of 0.01 PPM to 0.09 PPM. Once the chlorine concentration exceeds this value, the device will alarm at 2-HZ to warn the user of chlorine present at that set-point. The second set-point is factory set at 0.10 PPM.A chlorine concentration equal to or above the 0.10 PPM set-point will activate the buzzers and the red chlorine alarm indicators at 5 HZ for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The alarms can be by-passed. When by-passed the pulsing lights will turn solid and the buzzer will double click over 15 minutes.The front cover of the device has two screens. The screen of the chlorine monitor indicates the presence of combined chlorine when the value is not 0.000. The touch screen is used to enter user data and show the statuses of the device.

Nelson Environmental Technologies Inc

2025-04-16

Basic Chlorine Sentinel - The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. The Basic Chlorine Sentinel detects dissolved chlorine by an auxiliary meter detection technology, self-monitors for maintenance-required conditions, loss of electrical power, as well as two other system conditions such as flooding and the status of RO shutdown alarm. The device chlorine monitoring probe is preferably placed after the second carbon filter, before the RO machine or at the beginning of the patient water treatment loop.The device has three components – a lockable master control enclosure, a lockable probe/tester enclosure, and the remote module installed in the patient area.A chlorine concentration equal to or above the set-point (default: 0.10mg/L) will activate the buzzers and the red CHLORINE alarm indicators for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The yellow AUTO-TEST OK/CL DETECTED indication will latch. The AUTO-TEST/CL DETECTED indication can be deactivated after the event by pressing the blue RESET PUSHBUTTON on the front cover of the controller.A probe failure or the activation of one of the auxiliary input relays will activate the yellow MAINTENANCE needed indicators as well as the Buzzers which will remain activated as long as the condition exists. However, the buzzers can be muted by the key mute switch while the maintenance issue is being resolved.

Nelson Environmental Technologies Inc

2022-07-06