Basic Chlorine Sentinel

GUDID 00860006352103

The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. The Basic Chlorine Sentinel detects dissolved chlorine by an auxiliary meter detection technology, self-monitors for maintenance-required conditions, loss of electrical power, as well as two other system conditions such as flooding and the status of RO shutdown alarm. The device chlorine monitoring probe is preferably placed after the second carbon filter, before the RO machine or at the beginning of the patient water treatment loop. The device has three components – a lockable master control enclosure, a lockable probe/tester enclosure, and the remote module installed in the patient area. A chlorine concentration equal to or above the set-point (default: 0.10mg/L) will activate the buzzers and the red CHLORINE alarm indicators for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The yellow AUTO-TEST OK/CL DETECTED indication will latch. The AUTO-TEST/CL DETECTED indication can be deactivated after the event by pressing the blue RESET PUSHBUTTON on the front cover of the controller. A probe failure or the activation of one of the auxiliary input relays will activate the yellow MAINTENANCE needed indicators as well as the Buzzers which will remain activated as long as the condition exists. However, the buzzers can be muted by the key mute switch while the maintenance issue is being resolved.

Nelson Environmental Technologies Inc

Haemodialysis system chlorine monitor
Primary Device ID00860006352103
NIH Device Record Key13131fdc-e803-44d2-acab-35465555da12
Commercial Distribution StatusIn Commercial Distribution
Brand NameBasic Chlorine Sentinel
Version Model NumberNSS-BCS-001
Company DUNS835316464
Company NameNelson Environmental Technologies Inc
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usefalse
Lot Batchtrue
Serial Numbertrue
Manufacturing Datetrue
Expiration Datetrue
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptionfalse
OTC Over-The-Counterfalse

Device Identifiers

Device Issuing AgencyDevice ID
GS100860006352103 [Primary]

FDA Product Code

PSXChlorine Meter

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusNew
Device Record StatusPublished
Public Version Number1
Public Version Date2022-07-14
Device Publish Date2022-07-06

Devices Manufactured by Nelson Environmental Technologies Inc

00860006352127 - Water Purification System for Hemodialysis2023-08-25 Nelson Water System's Water Purification System for Hemodialysis is intended to be used for purifying the water used in hemodial
00860006352103 - Basic Chlorine Sentinel2022-07-14The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. The Basic Chlorine Sentinel detects dissolved chlorine by an auxiliary meter detection technology, self-monitors for maintenance-required conditions, loss of electrical power, as well as two other system conditions such as flooding and the status of RO shutdown alarm. The device chlorine monitoring probe is preferably placed after the second carbon filter, before the RO machine or at the beginning of the patient water treatment loop. The device has three components – a lockable master control enclosure, a lockable probe/tester enclosure, and the remote module installed in the patient area. A chlorine concentration equal to or above the set-point (default: 0.10mg/L) will activate the buzzers and the red CHLORINE alarm indicators for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The yellow AUTO-TEST OK/CL DETECTED indication will latch. The AUTO-TEST/CL DETECTED indication can be deactivated after the event by pressing the blue RESET PUSHBUTTON on the front cover of the controller. A probe failure or the activation of one of the auxiliary input relays will activate the yellow MAINTENANCE needed indicators as well as the Buzzers which will remain activated as long as the condition exists. However, the buzzers can be muted by the key mute switch while the maintenance issue is being resolved.
00860006352103 - Basic Chlorine Sentinel2022-07-14 The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treat

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.