NEOCOIL, LLC

Matched from indexed company URL: Neocoil, LLC

FDA Registration(s)

RegistrationFEINameStatusInitial importerExpiration yearAddress
30063694843006369484NEOCOIL, LLC1N2026-01-01N27 W23910A PAUL RD. Pewaukee WI US 53072

GUDID Contact Samples

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDIDProductPhoneEmail
0085002893249032ch AIR Open Coil Suite, 3.0T - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths: • AIR Open Head Neck Posterior 9ch • AIR Open Neck Chest Anterior 7ch • AIR Open Head Anterior 16ch The coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).+1 (262) 522-6124kate.gonzalez@neocoil.com
0085002893250632ch AIR Open Coil Suite, 1.5T - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths: • AIR Open Head Neck Posterior 9ch • AIR Open Neck Chest Anterior 7ch • AIR Open Head Anterior 16ch The coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).+1 (262) 522-6124kate.gonzalez@neocoil.com

Registered Device Listings

Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
732811177526630K22240716ch Breast Coil / 16ch Breast Coils, 1.5T 16ch Breast Coil, 3.0T 16ch Breast Coil, 1.5T 16ch Breast Coil, 3T 16ch Breast CoilMOS2022-10-14
732812027572987K21368732Ch AIR Open Coil Suite: 1.5T AIR Open Head Neck Posterior 9ch / 3.0T AIR Open Head Neck Posterior 9ch, 1.5T AIR Open Neck Chest Anterior 7ch / 3.0T AIR Open Neck Chest Anterior 7ch, 1.5T AIR Open Head Anterior 16ch / 3.0T AIR Open Head Anterior 16chMOS2022-03-11
732811830206659K2011011.5T 16ch Shoulder Coil, 3.0T 16ch Shoulder CoilMOS2020-06-02
732811684715495K1829581.5T 16ch Breast CoilMOS2018-11-16
732811836136069K173409Wireless Audio SystemLNH2018-02-16
732811053801654K1733773.0T 16ch Breast CoilMOS2017-11-28
732811933064032K160350ECG CT Gating DeviceJAK2016-06-16
732811633258184K1418323T 16CH FLEX SPEEDER, MEDIUM , 3T 16CH FLEX SPEEDER, LARGEMOS2014-07-31
732811435422858K133670HEADPHONES, PATIENT ALERT, STANDALONE INTERFACELNH2014-07-24
732811079302054K1334221.5T 16-CHANNEL FLEX COIL, SMALL 1.5T 16-CHANNEL FLEX COIL, LARGEMOS2013-12-26
732811480927796K1232721.5T 16CH FLEX SPEEDER LARGE, 1.5T 16CH FLEX SPEEDER MEDIUMMOS2013-03-28
732811467798926K1213621.5T 16CH FLEX SPEEDER LARGEMOS2012-06-15
732811046181158K1134741.5T GEM FLEX COILMOS2012-03-16
732811204429097K1033423.0T METAFLEXCOILMOS2010-12-23
732811533361097K101632METAFLEXCOILMOS2010-08-24
732811117950521K073236NEOCOIL 3.0T 32-CHANNEL TORSO ARRAY COIL FOR GEMOS2007-11-30
732811799510351K071611NEOCOIL 3.0T 8-CHANNEL SHOULDER ARRAY COILMOS2007-06-28
732811262311258K071311NEOCOIL 1.5T 8-CHANNEL SHOULDER ARRAY COILMOS2007-05-22
732811708388260K070778NEOCOIL 3.0T 6-CHANNEL CAROTID ARRAY COILMOS2007-04-11
732811236168887
732811962176774

Product Codes Associated With Registrations

Product codeRegistration listing recordsLatest decision
MOS162022-10-14
LNH22018-02-16
JAK12016-06-16

PMN

GUDID

32ch AIR Open Coil Suite, 3.0T - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths: • AIR Open Head Neck Posterior 9ch • AIR Open Neck Chest Anterior 7ch • AIR Open Head Anterior 16ch The coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

32ch AIR Open Coil Suite, 1.5T - The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths: • AIR Open Head Neck Posterior 9ch • AIR Open Neck Chest Anterior 7ch • AIR Open Head Anterior 16ch The coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).

NEOCOIL, LLC

2023-01-27

1.5T 16ch Shoulder Coil (Device) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

3.0T 16ch Shoulder Coil (FRU) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

1.5T 16ch Shoulder Coil (FRU) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

16ch Shoulder Coil, Replacement Pad Kit (FRU) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2021-01-04

3.0T 16ch Shoulder Coil (Device) - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2020-12-30

1.5T 16ch Shoulder Coil - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2020-09-09

3.0T 16ch Shoulder Coil - The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.

NEOCOIL, LLC

2020-07-17

3T 6CH Carotid Coil - The NeoCoil 3.OT 6-Channel Carotid Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the carotid arteries and associated vasculature from the sternal notch through the internal carotid arteries at the level of cervical vertebrae C1 in Magnetic Resonance Imaging Systems. Compared to predicate devices, the submitted device offers greater SNR due to its operating field strength of 3.0T, and a larger field-of-view due to the antenna layout.

NEOCOIL, LLC

2017-03-16

3T 32Ch Torso Coil - Anterior - The NeoCoil 3.OT 32-Channel Torso Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the chest, abdomen, and pelvic area in Magnetic Resonance Imaging Systems. The coil consists of 2 antenna arrays; a posterior and an anterior. The posterior array contains 17 elements to achieve 16 channels and is enclosed in a rigid housing. The anterior array also contains 17 elements to achieve the later 16 channels but is enclosed in a flexible housing. The coil is wrapped around the patient's torso with hook and loop straps. The NeoCoil 3.0T 32-Channel Torso Array Coil is for use with the GE S.OT HD Series MR System (K052293)

NEOCOIL, LLC

2017-03-16

3T 32Ch Torso Coil - Posterior - The NeoCoil 3.OT 32-Channel Torso Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the chest, abdomen, and pelvic area in Magnetic Resonance Imaging Systems. The coil consists of 2 antenna arrays; a posterior and an anterior. The posterior array contains 17 elements to achieve 16 channels and is enclosed in a rigid housing. The anterior array also contains 17 elements to achieve the later 16 channels but is enclosed in a flexible housing. The coil is wrapped around the patient's torso with hook and loop straps. The NeoCoil 3.0T 32-Channel Torso Array Coil is for use with the GE S.OT HD Series MR System (K052293)

NEOCOIL, LLC

2017-03-16

3T 8ch Shoulder Coil - The NeoCoil 3.OT 8-Channel Shoulder Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the shoulder in Magnetic Resonance Imaging Systems. Compared to predicate devices, the submitted device offers easier patient setup and greater SNR due to its compatibility with 3.OT MRI scanners. The submitted device consists of semi-flexible foam covered housing, consisting of eight antennas. The antennas are uniquely positioned with the appropriate overlap to cancel out mutual coupling effects from adjacent antennas or decoupled from an adjacent antenna using a transformer. Pre-amplifier decoupling reduces any remaining decoupling between the antennas. The coil is held in place over the imaging area via a cross body strap. A system interface cable connects to the coil at the top of the housing. The flexible foam covered housing along with the body strap enable the proper positioning on the patient before laying down and holds the coil in place while scanning is being performed. To ensure safety, each antenna is equipped with active and passive transmit decoupling circuits. Active decoupling is achieved via diodes that receive signals from the scanner to turn the coil to a high impedance state during system RF transmit. Crossed diodes are installed on each antenna acting as passive switches. These passive switches provide additional safety in case the active circuitry does not receive signal from the scanner.

NEOCOIL, LLC

2017-03-16

82 records. Showing 1-40. Next