O-TWO MEDICAL TECHNOLOGIES, INC.

Matched from indexed company URL: O-Two Medical Technologies Inc

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
96108613002807836O-TWO MEDICAL TECHNOLOGIES, INC.1N2026-01-0145A Armthorpe Road Brampton Ontario CA L6T 5M4

GUDID Contact Samples#

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDID, Product, Phone table
Source GUDIDProductPhoneEmail
07540195015012O-Two - Nitrile Powder Free Gloves(905) 792-6896resuscitation@otwo.com
07540195015029O-Two - Supply Hose Assembly9057926896resuscitation@otwo.com

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
95361941374087K991195CAREVENT BLS, CAREVENT BLS+, CAREVENT ALS, CAREVENT ALS+, AND CAREVENT ATVBTL1999-04-22
95361701128761K983705EMT RESUSCITATORBTL1998-10-29
95361814666605K960995CPR BIO-BARRIER FACESHEILDCBP1997-01-07
95361769463352K940927RESCUE BREATHERCBP1994-10-14
95361038217809K932170FLYNNR GENESIS II A/C, A/O AND IDLHBTL1993-10-25
95361609935429K922810ODYSSEYBTM1993-01-22
95361309416737K173205Equinox AdvantageBZR2018-08-29
95361637566444K170886HOMED Mesh NebulizerCAF2018-06-21
95361325044503K141595O-TWO E700,O-TWO E600,O-TWO E500BTL2015-03-16
95361598749980K121770HEADSTAR MEDICAL SMALL VOLUME JET NEBULIZERCAF2013-04-17
95361135636892K113687EQUINOX RELIEVEBZR2012-04-30
95361534523408K112546O_TWO CPAP SYSTEMBYE2011-12-27
95361000235084K102377VENTIPLUS DISPOSABLE MANOMETER 0-60 CM H2O; VENTIPLUS DISPOSABLE MANOMETER 0-20 CM H2O; VENTIPLUS DISPOSABLE MANOMETER 0CAP2010-11-18
95361431084615K093862CAREVENT HANDHELD CPAP SYSTEMBTL2010-05-06
95362073162110K081330CAREVENT PAR (PUBLIC ACCESS RESUSCITATOR)BTL2009-03-06
95361725661074K070371FINGERTIP PULSE OXIMETER MD300CDQA2007-08-13
95361847841436K051889CAREVENT CA AND DRABTL2005-08-30
95361695113570K051469CAREVENT ATV+ AND CAREVENT MRIBTL2005-09-28
95361643652401K040841POWDER FREE NITRILE EXAMINATION GLOVES (TESTED FOR USE WITH CHEMOTHERAPY DRUGS)LZA2004-07-08
95361925909217K021328SMART BAG MOBTM2003-06-26
95361707516674K002846HEADSTAR'S MANUAL EMERGENCY RESUSCITATORBTM2001-06-06
95361000635660
95361128477817
95361187143917
95361193848752
95361249273971
95361271288192
95361500798194
95361515764480
95361608456173
95361907042684
95361969219685
95362029944979

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
BTL82015-03-16
BTM32003-06-26
BZR22018-08-29
CAF22018-06-21
CBP21997-01-07
BYE12011-12-27
CAP12010-11-18
DQA12007-08-13
LZA12004-07-08

PMN#

GUDID#

O Two - Demand Valve Resuscitator- FERNO O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with a minimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation

O-Two Medical Technologies Inc

2024-04-29

O Two - Demand Valve Resuscitator- FERNO O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with a minimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation

O-Two Medical Technologies Inc

2024-04-29

Pro Nox - The PRO NOX Relieve Nitrous Oxide/Oxygen Analgesic Gas Mixing and Delivery System is a portable pneumatically powered device designed to provide a 50/50% nitrous oxide and oxygen mixture. It provides two input connectors for connection with nitrous oxide and oxygen cylinders through pressure regulators. The device has only one control for turning ON or OFF the device. When it is turned ON, the output of N2O/O2 gas mixture will only be activated by an inspiratory effort by the patient. The out put of N2O/O2 gas mixture is pre-set at 50/50%. Neither the patient nor medical personnel are able to adjust, eliminating the risk of delivering a hypoxic mixture.

O-Two Medical Technologies Inc

2023-11-13

O-Two - The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8015 with anti-entrainment flapper is specifically designed for use on O-Two automatic resuscitators and transport ventilators and other ventilators that respond to the spontaneous breathing.

O-Two Medical Technologies Inc

2019-05-31

O-Two - The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8016 is specifically designed for use with CAREvent MRI ventilators and is long enough to allow free passage of the patient in and out of the MRI unit without the risk of pulling on the tubing.

O-Two Medical Technologies Inc

2019-05-31

O-Two - The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8019 with anti-entrainment flapper and facemask/mouth piece is specifically designed for use with O-Two Equinox Relieve and Equinox Advantage nitrous oxide and oxygen gas mixing and delivery units.

O-Two Medical Technologies Inc

2019-05-31

O-Two - The O-Two single-use electronic ventilator ventilation circuit consists of a single ventilation corrugated hose and equipped with a flow sensor adapter designed to stream the flow without turbulence and create a differential pressure in two points which are connected to differential pressure sensor used to calculate flow. The unique one-way check valve will only allow flow from ventilator to patient and prevent the exhaled flow flowing back to the ventilator. All exhaled flow will be forced out to the atmosphere through the exhausted port of the breathing valve. The 01CV8030 is specifically designed for use with o_two e700, e600 and e500 electronic transport ventilators.

O-Two Medical Technologies Inc

2019-05-31

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed in a Royal Blue nylon keychain pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed with a pair of gloves in a Red nylon keychain/belt pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed with a pair of gloves in a Royal Blue nylon keychain/belt pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed in a BLACK nylon keychain pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed in a RED nylon keychain pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed in a Royal Blue nylon keychain pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed with a pair of gloves in a Black nylon keychain/belt pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed with a pair of gloves in a Red nylon keychain/belt pouch.

O-Two Medical Technologies Inc

2016-09-23

Rescue Breather CPR Protective Barrier - The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed with a pair of gloves in a Royal Blue nylon keychain/belt pouch.

O-Two Medical Technologies Inc

2016-09-23

O-Two - The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8015 with anti-entrainment flapper is specifically designed for use on O-Two automatic resuscitators and transport ventilators and other ventilators that respond to the spontaneous breathing.

O-Two Medical Technologies Inc

2019-05-31

O-Two - The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8016 is specifically designed for use with CAREvent MRI ventilators and is long enough to allow free passage of the patient in and out of the MRI unit without the risk of pulling on the tubing.

O-Two Medical Technologies Inc

2019-05-31

O-Two - The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8019 with anti-entrainment flapper and facemask/mouth piece is specifically designed for use with O-Two Equinox Relieve and Equinox Advantage nitrous oxide and oxygen gas mixing and delivery units.

O-Two Medical Technologies Inc

2019-05-31

O-Two - The O-Two single-use electronic ventilator ventilation circuit consists of a single ventilation corrugated hose and equipped with a flow sensor adapter designed to stream the flow without turbulence and create a differential pressure in two points which are connected to differential pressure sensor used to calculate flow. The unique one-way check valve will only allow flow from ventilator to patient and prevent the exhaled flow flowing back to the ventilator. All exhaled flow will be forced out to the atmosphere through the exhausted port of the breathing valve. The 01CV8030 is specifically designed for use with o_two e700, e600 and e500 electronic transport ventilators.

O-Two Medical Technologies Inc

2019-05-31

187 records. Showing 1-40. Next