SPINTECH, INC.

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30201625573020162557SPINTECH, INC.1N2026-01-0130200 Telegraph Road SUITE 140 Bingham Farms MI US 48025

GUDID Contact Samples#

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDID, Product, Phone table
Source GUDIDProductPhoneEmail
00866463000410STAGE - STAGE works as a comprehensive brain imaging post-processing solution. The STAGE system consists of a dedicated computer connected to the user’s local area network. The computer receives DICOM data from a specific MRI 3D GRE scan protocol (i.e. the STAGE protocol) and then outputs back numerous DICOM datasets with different types of contrast to wherever it received the files from (most likely a PACS server). The STAGE system will not contain any user interface. Instead, the data transfer will be initiated by the user’s current DICOM viewing software. The main method for user communication will be through DICOM output files that contain information in the image data. A method for remote connection to the STAGE computer will be included for updating and troubleshooting when an internet connection is available.(248) 712-6789info@spintechmri.com

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
2957371996416734K223079StageLNH2022-10-28

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
LNH12022-10-28

PMN#

Stage

2022-10-28

SpinTech, Inc.

STAGE

2021-06-29

SpinTech, Inc.

GUDID#

STAGE - STAGE is a MR post-processing software medical device intended for use in the visualization of the brain. STAGE analyzes input data from MR imaging systems. STAGE runs within a VM environment on hardware that meets the minimum requirements. STAGE utilizes magnitude and phase data acquired with specific parameters to generate enhanced T1 weighted images, SWI images, susceptibility enhanced images, pseudo-susceptibility maps, true SWI images, MR angiography (MRA) images, simulated T2 images, simulated T2 FLAIR images, simulated dual inversion recovery (DIR) images, and maps of T1, R2*, and proton density (PD). CROWN, introduced in STAGE, reduces noise some of these outputs, enhancing SNR and/or reducing imaging time. STAGE is indicated for brain imaging. Maximum and minimum intensity projections of some of these outputs will also be provided. The STAGE outputs can be configured to match the conventional acquisition series in MR protocols (i.e. routine brain w/) in terms of contrast, orientation and resolution. STAGE should always be used in combination with at least one other conventional MR acquisition technique (e.g. T2 FLAIR). STAGE input data can be acquired within a range of collection parameters, within shorter echo acquisitions allowing for less susceptibility affects and higher anatomic signal at the air tissue interface or with longer echo times for higher susceptibility effects around blood products and iron sources.

Spintech, Inc.

2025-03-27

STAGE - STAGE works as a comprehensive brain imaging post-processing solution. The STAGE system consists of a client supplied dedicated computer with an ethernet connection to the client’s existing local network. The STAGE software will operate within a virtual machine environment (virtual STAGE module) on this dedicated computer. The computer receives DICOM data from a specific MRI 3D GRE scan protocol (i.e., the STAGE protocol) and then outputs back numerous DICOM datasets with different types of contrast to the PACS server. The data transfer is initiated by the user’s current DICOM viewing software. STAGE has been modified from the predicate to include CROWN, a white noise filtering algorithm intended to improve specific STAGE outputs. The following table provide a summary of the methodology for each output with an example image and technical comparison to the predicate.

Spintech, Inc.

2023-02-23

STAGE - STAGE works as a comprehensive brain imaging post-processing solution. The STAGE system consists of a dedicated computer connected to the user’s local area network. The computer receives DICOM data from a specific MRI 3D GRE scan protocol (i.e. the STAGE protocol) and then outputs back numerous DICOM datasets with different types of contrast to wherever it received the files from (most likely a PACS server). The STAGE system will not contain any user interface. Instead, the data transfer will be initiated by the user’s current DICOM viewing software. The main method for user communication will be through DICOM output files that contain information in the image data. A method for remote connection to the STAGE computer will be included for updating and troubleshooting when an internet connection is available.

Spintech, Inc.

2021-10-06