Reveos Select CPD/AS-5 Red Cell Preservative For Collection Of Blood

Manufacturer
Terumo BCT Vietnam CO., Ltd. | Terumo BCT, Ltd.
Effective date
2025-01-14
Label type
HUMAN PRESCRIPTION DRUG LABEL
Version
3
Source
full-release
Hydrated at
2026-05-31 21:24:15

Label at a glance#

ProductReveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of Blood
Active ingredientDextrose Monohydrate, Trisodium Citrate Dihydrate, Anhydrous Citric Acid, Sodium Phosphate, Monobasic, Unspecified Form, Anhydrous Dextrose, Sodium Chloride, Mannitol, Adenine
Label structure14 sections

Indications and uses

The Reveos ® SELECT set is intended to collect a unit of whole blood and to process the whole blood unit on the Reveos Automated Blood Processing System, producing blood components. Rx only.

Dosage and administration

Set Diagram 1 Whole blood bag 7 Sample/diversion bag A, C: Y connector 2 Interim platelet unit (IPU) bag 8 Needle B, G: Blue clamp 3 Plasma bag 9 Needle injury protector (NIP) D, F, H, J: CLIKTIP frangible connector 4 Plasma cryoprecipitate reduced bag 10 Sample tube holder/luer adapter E: White clamp 5 Red blood cell (RBC) bag 11 Cross-connector 6 Residual leukocyte bag 12 RBC leukoreduction filter This document ...

Storage and handling

The blood bag sets are packaged in outer aluminum foil pouches. Each outer aluminum foil pouch contains 2 blood bag sets. Each case contains 8 outer aluminum foil pouches. CATALOG NUMBER NDC NUMBER 6FO506A0 Carton: 82906-506-16 Aluminum foil: 82906-506-02 Primary Collect Bag: 82906-506-01 Long-term storage temperature: 1 °C to 30 °C Permitted temperature excursions: –20 °C to 1 °C for up to 2 weeks Up to 50 °C for...

Label contents#

Full prescribing information#

1 INDICATIONS AND USAGE

INDICATIONS & USAGE SECTION

The Reveos® SELECT set is intended to collect a unit of whole blood and to process the whole blood unit on the Reveos Automated Blood Processing System, producing blood components.

Rx only.

2 DOSAGE AND ADMINISTRATION

DOSAGE & ADMINISTRATION SECTION

SPL UNCLASSIFIED SECTION

Set Diagram

Set Diagram
Set Diagram
1 Whole blood bag 7 Sample/diversion bagA, C: Y connector
2 Interim platelet unit (IPU) bag8 NeedleB, G: Blue clamp
3 Plasma bag9 Needle injury protector (NIP)D, F, H, J: CLIKTIP frangible connector
4 Plasma cryoprecipitate reduced bag10 Sample tube holder/luer adapterE: White clamp
5 Red blood cell (RBC) bag11 Cross-connector
6 Residual leukocyte bag12 RBC leukoreduction filter

This document provides blood collection and post-processing instructions specific to the Reveos SELECT set. For warnings, cautions, and instructions on processing whole blood with the Reveos system, see the Reveos system operator's manual.

Note: Refer to the instructions for use provided by the manufacturer of your tubing sealer to ensure that the tubing sealer is appropriate for the tubing on the blood bag set.

Note: You must validate the process for producing, storing, and handling Cryoprecipitated Antihemophilic Factor within your institution's standard operating procedure (SOP), including procedures for using the plasma cryoprecipitate reduced bag.

SPL UNCLASSIFIED SECTION

Blood Collection

Required Supplies:

  1. Scale and/or blood mixing device
  2. Tubing sealer
  3. Evacuated blood collection tubes
  4. If it is part of your institution's SOP, make a loose knot in the collection tubing between white clamp E and the whole blood bag.
  5. Separate the sample/diversion bag from the other bags.
  6. Load the bags onto a scale and/or blood mixing device according to your institution's SOP. Ensure that the whole blood bag and the sample bag are lower than the donor's arm.
  7. Close blue clamp B.
  8. Apply a blood pressure cuff or a tourniquet to the donor's arm.
  9. Prepare the venipuncture site.
  10. Twist the needle cap until the resistance stops and then pull the needle cap straight off.
  11. Perform the venipuncture according to your institution's SOP.
  12. Open blue clamp B.
  13. Position the sample/diversion bag with blue clamp B at the top and the sample tube holder/luer adapter at the bottom (see Figure 1). Allow the desired volume of whole blood to flow into the sample/diversion bag. The nominal volume of the sample bag is 60 mL. When the volume reaches the marking, approximately 40 mL has been collected.
  14. Close blue clamp B.
  15. Break CLIKTIP D to allow the whole blood to flow into the whole blood bag. Bend the CLIKTIP in both directions to ensure that you break it completely.
  16. Seal the sample/diversion tubing as near as possible to Y connector A. Seal the tubing according to your institution's SOP.
  17. Invert the sample/diversion bag and transfer donor blood samples from the sample/diversion bag, using evacuated blood collection tubes. Transfer samples as soon as possible after venipuncture to avoid possible clot formation in the sample/diversion bag.
    1. Hold the sample/diversion bag and sample tube holder/luer adapter in one hand with blue clamp B positioned at the bottom (see Figure 2).
    2. Using the other hand, insert a blood collection tube firmly into the sample tube holder/luer adapter. After filling the blood collection tube, remove the tube from the sample tube holder. Repeat the process to take additional samples.
  18. Mix the whole blood and the anticoagulant during collection according to your institution's SOP.
  19. Collect the target volume of blood ± 10%, as specified on the whole blood bag label.
  20. Close white clamp E and perform one of the following steps:
    • If you made a knot in the collection tubing in step 1, tighten the knot firmly.
    • If you did not make a knot in step 1, seal the collection tubing near CLIKTIP D.
  21. Hold the needle hub and then slide the NIP partially over the needle hub (see Figure 3).
  22. Gently pull on the tubing to withdraw the needle from the donor's arm and into the NIP until the needle locks securely (see Figure 4).
  23. Seal the collection tubing near CLIKTIP D if you did not do so in step 17. Disconnect the sealed tubing that includes the needle and the sampling assembly. Dispose of the needle, the NIP, and the sample tube holder safely according to your institution's SOP and/or local regulations.
  24. Immediately after collection is complete, invert the whole blood bag several times to thoroughly mix the whole blood and the anticoagulant.
  25. If required, strip the blood in the collection tubing into the whole blood bag according to your institution's SOP.
  26. Seal and disconnect the collection tubing between 1 in and 2 in (2.5 cm and 5.0 cm) away from the whole blood bag. Dispose of the collection tubing safely according to your institution's SOP and/or local regulations.
  27. Place the whole blood unit into a temperature-controlled environment according to your institution's SOP.
  28. Pack and transport the whole blood unit to the processing laboratory according to your institution's SOP.
Figure 1: Sample/diversion bagFigure 2: Collecting a whole blood sample

Figure 1Figure 1

Figure 2Figure 2

Figure 3: Sliding the NIP over the needle hubFigure 4: Withdrawing the needle into the NIP

Figure 3Figure 3

Figure 4Figure 4

SPL UNCLASSIFIED SECTION

Post-Processing and Red Blood Cell Leukoreduction

Required Supplies:

  1. Leukoreduction rack
  2. Tubing sealer
  3. After processing, remove the plasma bag, the plasma cryoprecipitate reduced bag, the residual leukocyte bag, and the IPU bag from the organizer and handle them according to your institution's SOP.
    Note: You must rest and agitate the IPU prior to platelet pooling. For conditions for resting and agitating the IPU, see the platelet pooling set instructions for use.
  4. Prepare a leukoreduction rack with a head height of at least 43½ in (110 cm).
  5. Remove the RBC bag from the organizer.
  6. Hang the RBC bag from the leukoreduction rack so that the filter hangs vertically.
  7. Open blue clamp G.
  8. Break CLIKTIP H.
  9. Break CLIKTIP J.
  10. Drain all of the additive solution through the filter and into the whole blood bag.
  11. Close blue clamp G.
  12. Gently mix the additive solution with the RBC unit in the whole blood bag.
  13. Hang the whole blood bag on the leukoreduction rack.
  14. Ensure that the tubing is free of kinks or other obstructions.
  15. Open blue clamp G and allow the mixture of red blood cells and additive solution to flow through the leukoreduction filter.
    Do not squeeze the whole blood bag to increase the draining rate. Filtration is complete when the inlet side of the leukoreduction filter collapses and the red blood cells drain from the inlet side of the filter.
  16. Seal the RBC tubing below the leukoreduction filter and disconnect the RBC bag. Ensure that the filter remains in a vertical position while you seal the tubing, as this prevents the loss of red blood cells.
  17. Dispose of the whole blood bag and filter assembly safely according to your institution's SOP and/or local regulations.
  18. Seal the line for sampling segments according to your institution's SOP.
  19. Store the RBC product according to your institution's SOP.

Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration, whenever the solution and container permit.

3 DOSAGE FORMS AND STRENGTHS

DOSAGE FORMS & STRENGTHS SECTION

70 mL Citrate Phosphate Dextrose (CPD) anticoagulant is a sterile solution in a PVC plasticized with DEHP bag. Each 70 mL of CPD contains: Dextrose (anhydrous) 1.624 g, Trisodium Citrate (dihydrate) 1.841 g, Citric Acid (monohydrate) 0.229 g, Sodium Dihydrogen Phosphate (dihydrate) 0.176 g, and water for injection up to 70 mL.

111 mL Additive Solution 5 (AS-5) red cell preservative solution is a sterile solution in a PVC plasticized with DEHP bag. Each 111 mL of AS-5 contains: Dextrose (anhydrous) 0.908 g, Sodium Chloride 0.973 g, Mannitol 0.583 g, Adenine 0.035 g, and water for injection up to 111 mL.

4 CONTRAINDICATIONS

CONTRAINDICATIONS SECTION

None.

5 WARNINGS AND PRECAUTIONS

WARNINGS AND PRECAUTIONS SECTION

  • Single-use product. Do not reuse. This product is intended to be single use only and is not intended to be reused or re-sterilized in any manner. Terumo Blood and Cell Technologies cannot ensure the functionality or sterility of the product if it is reused or re-sterilized. Reuse of a single-use disposable set may result in:
    • Product performance issues due to loss of product integrity, including but not limited to the following:
      • Fluid leaks
      • Parts that are warped or deformed
      • Plastics that are brittle and discolored
      • Filters that have reduced filtration capabilities
    • Viral infections such as hepatitis or human immunodeficiency virus (HIV)
    • Bacterial infections
    • Cross-contamination
    Any of these risks could result in serious injury or death. These risks are shared by product users, donors, patients, and recipients of the end product of the device.
  • Inspect the packaging and the blood bag set prior to use. Do not use the set if any of the following conditions are present:
    • There are tears or holes in the outer aluminum foil packaging or in the individual transparent packaging wrap.
    • The tubing has severe kinks.
    • The blood bag set is incorrectly assembled.
    • The blood bag set is defective or damaged, or there are any leaks from the fluid-filled components of the set.
    • Any clamps are closed.
    • The needle cap is not in place.
    • The solutions are cloudy or discolored or contain particulates.
    Using the blood bag set under these conditions may result in product contamination or poor performance during collection and/or processing.
    Note: It is normal to have some condensation in the outer aluminum foil pouch and individual transparent packaging wrap due to sterilization.
  • The blood bag set is no longer sterile if any of the following conditions occur:
    • You disconnect the sample/diversion bag before you seal the sample/diversion tubing.
    • You remove blood samples before you seal the sample/diversion tubing.
    • The integrity of the set is compromised for any reason.
    Manage the blood bag set according to your institution's SOP.
  • Do not process whole blood less than 2 hours after collection. Processing blood too soon after collection may result in incomplete RBC leukoreduction and/or a reduced platelet yield.
  • Residual leukocytes are a by-product of the processing procedure and contain mostly white blood cells (WBC), with some plasma, platelets, and red blood cells (RBC). Residual leukocytes are not intended for transfusion.
  • Use aseptic technique during blood collection to ensure donor safety and product quality.
  • Do not vent the blood bag set.

6. ADVERSE REACTIONS

ADVERSE REACTIONS SECTION

To report SUSPECTED ADVERSE REACTIONS, contact Terumo BCT, Inc. at 1-877-339-4228 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.

8 USE IN SPECIFIC POPULATIONS

USE IN SPECIFIC POPULATIONS SECTION

The Reveos SELECT set has not been adequately studied in controlled clinical trials with specific populations.

11 DESCRIPTION

DESCRIPTION SECTION

The Reveos SELECT set has been evaluated for use with the Reveos system.

The blood and fluid pathways of the blood bag set are steam-sterilized and are non-pyrogenic.

The blood bag set is intended for use by appropriately trained phlebotomists who collect whole blood and by blood center personnel who process whole blood using the Reveos system.

The formulas of the active ingredients are provided in Tables 1 and 2.

Table 1: CPD Active Ingredients
IngredientsMolecular FormulaMolecular Weight
Dextrose (anhydrous)C6H12O6 180.16 g/mol
Trisodium Citrate (dihydrate)C6H5Na3O72H2O294.10 g/mol
Citric Acid (monohydrate)C6H8O7H2O210.14 g/mol
Sodium Dihydrogen Phosphate (dihydrate)NaH2PO42H2O156.01 g/mol
Water for InjectionH2O18.02 g/mol

Each 70 mL of CPD contains: Dextrose (anhydrous) 1.624 g, Trisodium Citrate (dihydrate) 1.841 g, Citric Acid (monohydrate) 0.229 g, Sodium Dihydrogen Phosphate (dihydrate) 0.176 g, and water for injection up to 70 mL.

Table 2: AS-5 Active Ingredients
IngredientsMolecular FormulaMolecular Weight
Dextrose (anhydrous)C6H12O6 180.16 g/ mol
Sodium ChlorideNaCl 58.44 g/mol
MannitolC6H14O6 182.17 g/mol
AdenineC5H5N5 135.13 g/mol
Water for injectionH2O18.02 g/mol

Each 111 mL of AS-5 contains: Dextrose (anhydrous) 0.908 g, Sodium Chloride 0.973 g, Mannitol 0.583 g, Adenine 0.035 g, and water for injection up to 111 mL.

The PVC plasticized with DEHP bags are not made with natural rubber latex.

The bags contain materials that have been tested to demonstrate the suitability of the containers for storing pharmaceutical solutions. The bags are nontoxic and biologically inert. The blood bag set is a closed system and is not dependent upon entry of external air during administration. The blood bag set is overwrapped to provide protection from the physical environment and to provide an additional moisture barrier when necessary.

12 CLINICAL PHARMACOLOGY

CLINICAL PHARMACOLOGY SECTION

12.1. Mechanism of Action

MECHANISM OF ACTION SECTION

SPL UNCLASSIFIED SECTION

CPD Mechanism of Action

CITRATE PHOSPHATE DEXTROSE acts as an extracorporeal anticoagulant by binding the free calcium in the blood. Calcium is a necessary co-factor to several steps in the clotting cascade. The following ingredients are key components of the solution:

  • Citric Acid for pH regulation
  • Sodium Citrate functions as an anticoagulant
  • Dextrose for isotonicity
  • Sodium Dihydrogen Phosphate for pH buffering

This solution has no clinical effect in transfused patients.

SPL UNCLASSIFIED SECTION

AS-5 Mechanism of Action

ADDITIVE SOLUTION FORMULA 5 acts to preserve and extend the shelf life of packed RBC products for later transfusion to patients. The following ingredients are key components of the solution:

  • Dextrose for RBC nutrition
  • Sodium Chloride for isotonicity
  • Mannitol to protect RBC membranes
  • Adenine to support adenosine triphosphate (ATP) levels

This solution has no clinical effect in transfused patients.

16 HOW SUPPLIED/STORAGE AND HANDLING

HOW SUPPLIED SECTION

The blood bag sets are packaged in outer aluminum foil pouches. Each outer aluminum foil pouch contains 2 blood bag sets. Each case contains 8 outer aluminum foil pouches.

CATALOG NUMBERNDC NUMBER
6FO506A0Carton:82906-506-16
Aluminum foil:82906-506-02
Primary Collect Bag:82906-506-01

STORAGE

STORAGE AND HANDLING SECTION

  • Long-term storage temperature: 1 °C to 30 °C
  • Permitted temperature excursions:
    • –20 °C to 1 °C for up to 2 weeks
    • Up to 50 °C for up to 1 week

Use blood bag sets within 28 days after you open the outer aluminum foil pouch. To store unused blood bag sets, return them to the outer aluminum foil pouch and reclose the pouch with tape or a clip. Once you open the transparent packing wrap, you must use the blood bag set within 7 days, not exceeding 28 days from when you opened the outer aluminum foil pouch. Each outer aluminum foil pouch contains sachets that absorb oxygen. Dispose of the sachets and the outer aluminum foil pouch with normal waste.

SPL UNCLASSIFIED SECTION

Issued: February 2023

Manufactured by:
TERUMO BCT Vietnam CO., Ltd.
Long Duc Industrial Park, Long Duc Commune,
Long Thanh District, Dong Nai Province, Vietnam

For:
Terumo BCT, Inc.
10811 W. Collins Ave.

Lakewood, CO 80215

RETURN OF USED PRODUCT

SPL UNCLASSIFIED SECTION

If for any reason this product must be returned to Terumo BCT, Inc., a returned goods authorization (an RGA number) is required from Terumo BCT prior to shipping. Instructions for cleaning and materials, including appropriate shipping containers, proper labeling, and an RGA number, may be obtained from the Terumo BCT Quality Assurance Department. IT IS THE RESPONSIBILITY OF THE HEALTH CARE INSTITUTION TO ADEQUATELY PREPARE AND IDENTIFY THE PRODUCT FOR RETURN SHIPMENT. Please contact your local representative for information regarding returned goods and product complaints.

Tubing Specifications (non-sterile, nominal* dimensions)
Total SpecificationsTotal Specifications 
DescriptionPrimary tubingSample tube holder/luer adapter tubing
Item(s)1, 2, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 143
Wall Thickness0.7 mm1.3 mm
Outer Diameter4.4 mm4.4 mm
Inner Diameter3.0 mm1.8 mm
 

* Note: The tubing dimensions listed on this document are nominal values and are intended for use in determining compatibility with various types of laboratory equipment. The nominal values are specified target dimensions; however, because they are based on non‑sterile tubing measurements, and due to variations in the manufacturing process, the actual dimensions may be slightly different.

Tubing Set Composition

  • Primary tubing: Polyvinyl chloride (PVC) plasticized with Di(2-ethylhexyl)phthalate (DEHP)
  • Bags: PVC plasticized with DEHP
  • RBC leukoreduction filter: PVC plasticized with DEHP housing, polybutylterephthalate media
  • Access needle: Stainless steel (contains cobalt)
  • Needle injury protector (NIP): Polypropylene (PP)
  • Sample tube holder/luer adapter: PVC/polycarbonate housing, stainless steel needle
  • Clamps: Polyacetal
  • Cross-connector: PVC

Not made with natural rubber latex.

SPL UNCLASSIFIED SECTION

This product may be covered by one or more patents or pending patent applications.

See TERUMOBCT.COM/patents for details.

Terumo BCT, Inc. ("Terumo Blood and Cell Technologies", "Terumo BCT")

PRINCIPAL DISPLAY PANEL - 70 mL Bag Pouch Case Label

PACKAGE LABEL.PRINCIPAL DISPLAY PANEL

TERUMO Reveos® SELECT

CPD/AS-5 RED CELL PRESERVATIVE SOLUTION FOR COLLECTION OF 500mL OF BLOOD

CAUTIONS:

For single use only. Sterile fluid path, sterilized
using steam. Non-pyrogenic fluid path.

Do not re-sterilize.

Read the instructions carefully before use.

Do not use if package is damaged.

Store between 1°C and 30°C

Manufactured by :

TERUMO BCT Vietnam Co., Ltd.

Long Duc Industrial Park, Long Duc Commune,
Long Thanh District, Dong Nai Province, Vietnam

For :

TERUMO BCT, Inc.

10811 W. Collins ave.
Lakewood, CO 80215

Rx ONLY

D0000036575-A

XXXX

LOT : LOT #

MFG DATE : Date of Mfg.

EXPIRY DATE : Exp. Date

CAT. NO. : 6FO506A0

UNITS : 016

NDC : 82906-506-16

NDC (ISBT 128)

PRINCIPAL DISPLAY PANEL - 70 mL Bag Pouch Case Label
PRINCIPAL DISPLAY PANEL - 70 mL Bag Pouch Case Label

DailyMed Pharmacologic Classes#

Class, Version, Type table
ClassVersionTypeEffective
ANHYDROUS CITRIC ACID Pharmacologic Class Indexing3Indexing - Pharmacologic Class20180813
MANNITOL Pharmacologic Class Indexing2Indexing - Pharmacologic Class20180813
SODIUM CATION Pharmacologic Class Indexing2Indexing - Pharmacologic Class20180813

DailyMed Product Concepts#

Product concept, Relation, Version table
Product conceptRelationVersionEffective
95250459-30e4-45c1-b08a-993044f49109Product name220250805
efd58dcf-540a-4531-8766-e713129ca6f2Product name120250307
30b0ac6e-02aa-0e5c-0d8b-cffdf3a282b2Product name520250304
4b7700e3-6e0e-45e5-9d22-6f754d61386eProduct name220250304
726062af-1135-4707-a1d7-57256991bbf9Product name220250226
a21a21e5-f36d-4c1f-8918-def921b8f7e3Product name320250124
bed0530e-f939-4541-956b-6928a2f6404fProduct name120241008
cefa60e2-a5b5-493e-9c54-24735b7dc509Product name620240814
fb7ab793-2c12-4079-b100-a64f73bef25aProduct name420240712
362d7abb-94e6-4c60-9a58-266894157713Product name120231023
b0cbf770-6cc3-4aa4-9158-755110c2b9f7Product name220230717
cb89b86a-369e-4204-8910-ae797c503af3Product name120230706
dc7c5daa-021f-40dd-b00d-63982cb2067aProduct name120230426
6bd95106-a412-1dad-b9cc-4cb74bfb27ceProduct name220230315
f1e0dc7e-7d61-4625-b6d9-4894927679d7Product name220211025
9badc7be-250a-44ab-aa36-926af3f02679Product name120210527
08ffbcbf-26df-b99c-1dab-64fc4cfae89fProduct name520200925
e4870509-7e28-6f92-f0be-dd3dd889a9cfProduct name520200810
6e9d4a47-c464-b93e-aebc-ad7bffc9c4cdProduct name220190619
444b3e50-f226-46ef-bfca-2e7035d140cdProduct name120190611
816b97af-edc5-4060-aff1-b814bdbcad50Product name120190415
d4880ace-a516-8c47-8dfd-73a4ba5887d7Product name220180830
7cda52fc-125f-421c-8fea-bc1974370c49Product name220180703
cefa60e2-a5b5-493e-9c54-24735b7dc509Product name220171212
419aab54-5d5a-4146-9453-026d4a9991beProduct name220170525
26acd337-b838-40ac-bcbc-05c3b81c8712Product name120170323
08ffbcbf-26df-b99c-1dab-64fc4cfae89fProduct name220160823
d5e51f11-ad28-caa4-4b49-4143974782adProduct name120150831
290f523a-f9db-9774-b5a9-e1f908ac1782Product name120150828
0ca1d589-929b-4b33-bc5b-1d84abdafa6aProduct name120150324
fc363c46-397b-4476-ac0f-70e43e8e4592Product name120150324
89dac932-b90a-4410-9ab1-84c53e57de25Product name120150316
19c71a3d-ed9c-166b-a7e5-38c250c35631Product name120140508
5668b646-cd56-c3c7-bdea-3f6b1a8840dbProduct name120140508
597b1cfd-7b31-5048-62be-ca5cd740da2fProduct name120140508
684ea482-2e8b-14af-5664-b98f1e402036Product name120140508
810ab97e-f109-f41c-7c83-6a652a9cbf43Product name120140508
87711080-88eb-65c5-b2dd-bf99e700a372Product name120140508
8dbefedf-0a0d-a224-5a3c-66dc9e11c2ddProduct name120140508
b060cc1a-fe47-856b-0b77-4448b5963de8Product name120140508
c6b65c52-69c7-df49-550a-a50c137f6218Product name120140508
ec2149b3-5c6d-5344-f757-c86411073075Product name120140508
ed912195-5da0-0f2f-6f4b-3ef17710cbe3Product name120140508

DailyMed Package Descriptions#

Package NDC, Product, Description table
Package NDCProductDescriptionFormQuantityStrengthSPL version
82906-010-70Reveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of Blood70 mL in 1 BAGSOLUTION70 mL1.624 g in 70mL3
82906-020-11Reveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of Blood111 mL in 1 BAGSOLUTION111 mL0.973 g in 111mL3
82906-506-01Reveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of Blood1 in 1 BAGKIT13
82906-506-02Reveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of Blood2 in 1 POUCHKIT23
82906-506-16Reveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of Blood8 in 1 CASEKIT83

DailyMed Dashboard NDC Coverage#

NDC, Dashboard title, SPL version table
NDCDashboard titleSPL versionValidationDashboard ZIP
82906-010REVEOS SELECT CPD WITH AS-5 RED CELL PRESERVATIVE SOLUTION FOR COLLECTION OF 500ML OF BLOOD (ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) AND AS-5 RED CELL PRESERVATIVE) KIT [TERUMO BCT VIETNAM CO., LTD.]3Unmatched20250129_58bdabc8-283a-47bd-8abe-dd9284f3f497.zip
82906-020REVEOS SELECT CPD WITH AS-5 RED CELL PRESERVATIVE SOLUTION FOR COLLECTION OF 500ML OF BLOOD (ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) AND AS-5 RED CELL PRESERVATIVE) KIT [TERUMO BCT VIETNAM CO., LTD.]3Unmatched20250129_58bdabc8-283a-47bd-8abe-dd9284f3f497.zip
82906-506REVEOS SELECT CPD WITH AS-5 RED CELL PRESERVATIVE SOLUTION FOR COLLECTION OF 500ML OF BLOOD (ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) AND AS-5 RED CELL PRESERVATIVE) KIT [TERUMO BCT VIETNAM CO., LTD.]3Current NDC, 5 package rows20250129_58bdabc8-283a-47bd-8abe-dd9284f3f497.zip

Products#

Every source-derived product name is available through these pages.

DailyMed product names page 1 of 1 · 18 matching rows.

NDC Codes#

Ingredients#

Every source-derived ingredient row is available through these pages.

DailyMed ingredient rows page 1 of 1 · 10 matching rows.

Source Document#

Source XML

openFDA label cross-check#

OpenFDA label data provides additional search and identifier links. DailyMed’s Structured Product Label is the canonical label on FDA.report. Matching records are deduplicated before they are shown below.

Matched openFDA labels page 1 of 1 · 1 matching rows.

Brand, Generic, Manufacturer table
BrandGenericManufacturerSPL set IDEffective dateAvailable safety fieldsJoin
Reveos Select CPD with AS-5 Red Cell Preservative Solution For Collection Of 500ml Of BloodANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) AND AS-5 RED CELL PRESERVATIVETerumo BCT Vietnam CO., Ltd.58bdabc8-283a-47bd-8abe-dd9284f3f4972025-01-14Warnings, Adverse reactionsExact identifier
ndc (package): 82906-010-70
ndc (package): 82906-506-02
ndc (package): 82906-506-16
ndc (package): 82906-020-11
ndc (package): 82906-506-01
ndc (product): 82906-506
ndc11 (package): 82906050616
ndc11 (package): 82906001070
ndc11 (package): 82906050601
ndc11 (package): 82906002011
ndc11 (package): 82906050602
spl id: 58e10989-9dca-4ffa-8fd6-d3606b69f77a
spl set id: 58bdabc8-283a-47bd-8abe-dd9284f3f497

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.