E-Z-Disk by is a Prescription medication manufactured, distributed, or labeled by E-Z-EM, INC., Confab Laboratories Inc, E-Z-EM Canada Inc. Drug facts, warnings, and ingredients follow.
E-Z-DISK™ is an oral solid radiographic contrast agent. Each tablet contains 700 mg of barium sulfate and is ½ inch in diameter. The active ingredient is barium sulfate and its structural formula is BaSO4. Barium sulfate occurs as a fine, white, odorless, tasteless, bulky powder which is free from grittiness. Its aqueous suspensions are neutral to litmus. It is practically insoluble in water, solutions of acids and alkalies, and organic solvents.
Barium sulfate, due to its high molecular density is opaque to x-rays and therefore acts as a positive contrast agent for radiographic studies. Barium sulfate is biologically inert and therefore is not absorbed or metabolized by the body, and is eliminated unchanged from the body.
E-Z-DISK tablets disintegrate within 30 minutes after ingestion, and the fragments are eliminated with the feces without absorption of the barium sulfate. A brief delay in transit may sometimes be seen in elderly patients, particularly above the hiatus, or at the level of the aortic arch. In such instances, a sip of water is sufficient to carry the tablet down the esophagus.
Rarely, severe allergic reactions of an anaphylactoid nature have been reported following administration of barium sulfate contrast agents. Appropriate facilities and trained personnel should be available for emergency treatment of severe reactions and should remain available for at least 30 to 60 minutes following administration, since delayed reactions can occur.
Diagnostic procedures which involve the use of radiopaque contrast agents should be carried out under the direction of personnel with the requisite training and with a thorough knowledge of the particular procedure to be performed. A history of bronchial asthma, atopy, as evidenced by hay fever and eczema, or a previous reaction to a contrast agent, warrant special attention.
Use with caution in patients with complete or nearly complete esophageal or gastric obstruction.
Before administration of this product, patients receiving barium sulfate diagnostic agents should be instructed to:
Adverse reactions, such as nausea, vomiting, diarrhea and abdominal cramping accompanying the use of barium sulfate suspensions are infrequent, usually mild, and generally do not occur with this product. Procedural complications are rare, but may include aspiration pneumonitis, granuloma formation, intravasation, embolization and peritonitis following intestinal perforation, vasovagal and syncopal episodes, and fatalities. It is of the utmost importance to be completely prepared to treat any such occurrence.
Due to the increased likelihood of allergic reactions in atopic patients, it is important that a complete history of known and suspected allergies as well as allergic-like symptoms, e.g., rhinitis, bronchial asthma, eczema and urticaria, be obtained prior to any medical procedure utilizing these products. A mild allergic reaction would most likely include generalized pruritus, erythema or urticaria. Such reactions will generally respond to an antihistamine such as 50 mg of diphenhydramine, or its equivalent. In the rarer, more serious reactions, laryngeal edema, bronchospasm or hypotension could develop. Severe reactions which may require emergency measures are often characterized by peripheral vasodilation, hypotension, reflex tachycardia, dyspnea, agitation, confusion and cyanosis progressing to unconsciousness. Treatment should be initiated immediately with 0.3 to 0.5 mL of 1:1000 epinephrine subcutaneously. If bronchospasm predominates, 0.25 to 0.50 grams of intravenous aminophylline should be given slowly. Appropriate vasopressors might be required. Adrenocorticosteroids, even if given intravenously, exert no significant effect on the acute allergic reactions for a few hours. The administration of these agents should not be regarded as emergency measures for the treatment of allergic reactions. All levels of allergic reactions are extremely rare with this product. Apprehensive patients may develop weakness, pallor, tinnitus, diaphoresis and bradycardia following the administration of any diagnostic agent. Such reactions are usually non-allergic in nature and are best treated by having the patient lie flat for an additional 10 to 30 minutes under observation.
This tablet is most useful in patients experiencing dysphagia, particularly in those whose findings are deemed inconclusive by conventional methods. The problems associated with obtaining satisfactory films exhibiting complete filling of the pharynx and cricopharyngeal area make for difficult diagnosis in this region. In such cases, failure of the tablet to freely pass this site may indicate significant esophageal disease as cause of the symptoms, and may warrant further videographic studies.
The patient
should be instructed to swallow one tablet intact, with the aid of
one or two swallows of water, just prior to fluoroscopic examination.
Note: Using a tablet of known diameter (½ inch) not
only illustrates the presence of a significant narrowing of the esophagus,
but also provides a simple technique to measure the lumen at the site
of the stricture. The most routinely used esophagoscope has external
diameter of 36 French, and thus a tablet of corresponding half-inch
diameter was selected. The actual diameter (in inches) of the narrow
site is one-half the ratio of its measure value on the film to the
measure of the tablet
Upon swallowing the tablet, the patient experiences no significant discomfort, and fluid passes around the tablet without difficulty.
E-Z-DISK™ is a white tablet with EZEM on one
side and 778 on the other side and is supplied in the following manner:
Bottles of 100 ½-inch diameter, flat-sided tablets; Cat. No. 778,
NDC: 10361-778-31
E-Z-DISK
barium sulfate tablet |
||||||||||||||||||
|
||||||||||||||||||
|
||||||||||||||||||
|
||||||||||||||||||
|
||||||||||||||||||
|
Labeler - E-Z-EM, INC. (002041226) |
Registrant - E-Z-EM, INC. (002041226) |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Confab Laboratories Inc | 241754217 | MANUFACTURE(10361-778) , LABEL(10361-778) , PACK(10361-778) , ANALYSIS(10361-778) |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
E-Z-EM Canada Inc | 204211163 | ANALYSIS(10361-778) |