Dextrose and Sodium Chloride by is a Prescription medication manufactured, distributed, or labeled by Baxter Healthcare Corporation. Drug facts, warnings, and ingredients follow.
Dextrose and Sodium Chloride Injection is indicated as a source of water, electrolytes and calories. (1)
Dextrose and Sodium Chloride Injection is available in multiple strengths. See full prescribing information for detailed description of each product. (3)
Adverse reactions include electrolyte imbalances, hyperglycemia, and hypervolemia and injection site reactions. (6)
To report SUSPECTED ADVERSE REACTIONS, contact Baxter Healthcare at 1-866-888-2472 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
See 17 for PATIENT COUNSELING INFORMATION.
Revised: 8/2019
The choice of the specific, sodium chloride, and dextrose concentrations, rate and volume depends on the age, weight, clinical and metabolic conditions of the patient and concomitant therapy. Electrolyte supplementation may be indicated according to the clinical needs of the patient.
The administration rate should be governed, especially for premature infants with low birth weight, during the first few days of therapy, by the patient’s tolerance to dextrose. Increase the infusion rate gradually as indicated by frequent monitoring of blood glucose concentrations [see Warnings and Precautions (5.2), Use in Specific Populations (8.4)].
To Open
Preparation for Administration
To Add Medication
To Add Medication Before Solution Administration
To Add Medication During Solution Administration
Storage
Dextrose and Sodium Chloride Injection are clear solutions in 250 mL, 500 mL and 1000 mL single-dose, flexible containers:
250 mL flexible container
500 mL flexible container
1000 mL flexible container
Dextrose and Sodium Chloride Injection is contraindicated in patients with:
Hypersensitivity and infusion reactions, including anaphylaxis, have been reported with Dextrose and Sodium Chloride Injection [see Adverse Reactions (6)]. Stop the infusion immediately if signs or symptoms of a hypersensitivity or infusion reaction develops [see Contraindications (4)]. Appropriate therapeutic countermeasures must be instituted as clinically indicated.
The use of dextrose infusions in patients with impaired glucose tolerance may worsen hyperglycemia. Administration of dextrose at a rate exceeding the patient’s utilization rate may lead to hyperglycemia, coma, and death.
Hyperglycemia is associated with an increase in serum osmolality, resulting in osmotic diuresis, dehydration and electrolyte losses. Patients with underlying central nervous system disease and renal impairment who receive dextrose infusions, may be at greater risk of developing hyperosmolar hyperglycemic state.
Monitor blood glucose concentrations and treat hyperglycemia to maintain concentrations within normal limits while administering Dextrose and Sodium Chloride Injection. Insulin may be administered or adjusted to maintain optimal blood glucose concentrations.
Dextrose and Sodium Chloride Injection is a hypertonic solution [see Description, Table 1 (11)]. In the body, however, glucose containing fluids can become extremely physiologically hypotonic due to rapid glucose metabolization. Monitoring of serum sodium is particularly important for hypotonic fluids.
Depending on the tonicity of the solution, the volume and rate of infusion, and depending on a patient’s underlying clinical condition and capability to metabolize glucose, intravenous administration of glucose can cause electrolyte disturbances, most importantly hypo- or hyperosmotic hyponatremia.
The risk for hyponatremia is increased, in pediatric patients, elderly patients, postoperative patients, those with psychogenic polydipsia and in patients treated with medications that increase the risk of hyponatremia (such as certain diuretic, antiepileptic and psychotropic medications) [see Drug Interactions (7.1)].
Acute hyponatremia can lead to acute hyponatremic encephalopathy characterized by headache, nausea, seizures, lethargy and vomiting. Patients with brain edema are at particular risk of severe, irreversible and life-threatening brain injury. Patients at increased risk for developing complications of hyponatremia, such as hyponatremic encephalopathy include pediatric patients; women, in particular, premenopausal women; patients with hypoxemia; and in patients with underlying central nervous system disease [see Use in Specific Populations (8.4, 8.5)].
Avoid Dextrose and Sodium Chloride Injection in patients with or at risk for hyponatremia. If use cannot be avoided, monitor serum sodium concentrations.
Rapid correction of hyponatremia is potentially dangerous with risk of serious neurologic complications such as osmotic demyelination syndrome with risk of seizures and cerebral edema. To avoid complications, monitor serum sodium and chloride concentrations, fluid status, acid-base balance, and signs of neurologic complications.
High volume infusion must be used with close monitoring in patients with cardiac or pulmonary failure, and in patients with non-osmotic vasopressin release (including SIADH), due to the risk of hospital-acquired hyponatremia.
Excessive administration of Dextrose and Sodium Chloride Injection may result in significant hypokalemia. Hypokalemic periodic paralysis, metabolic alkalosis, increased gastrointestinal losses (e.g. diarrhea, vomiting), prolonged low potassium diet, or primary hyperaldosteronism may increase the risk of hypokalemia.Avoid the administration of Dextrose and Sodium Chloride Injection in patients with or at risk of hypokalemia or taking medications that may increase the risk. If use cannot be avoided, monitor serum potassium levels.
Electrolyte imbalances such as hypernatremia and hyperchloremia, leading to metabolic acidosis may occur with solutions containing 0.9% sodium chloride.
Conditions that may increase the risk of hypernatremia, fluid overload and edema (central and peripheral), include patients with pre-eclampsia, primary hyperaldosteronism and secondary hyperaldosteronism associated with, for example, hypertension, congestive heart failure, severe renal impairment, liver disease (including cirrhosis), and renal disease (including renal artery stenosis, nephrosclerosis).
Medications such as corticosteroids or corticotropin, may increase the risk of sodium and fluid retention.
Avoid in patients with or at risk for hypernatremia. If use cannot be avoided, monitor serum sodium concentrations.
Rapid correction of hypernatremia is potentially dangerous with risk of serious neurologic complications. Excessively rapid correction of hypernatremia is also associated with a risk for serious neurologic complications such as osmotic demyelination syndrome (ODS) with risk of seizures and cerebral edema.
Depending on the volume and rate of infusion, the patient’s underlying clinical condition and capability to metabolize dextrose, intravenous administration of Dextrose and Sodium Chloride Injection can cause fluid and/or solute overloading resulting in dilution of serum electrolyte concentrations, overhydration, congested states or pulmonary edema.
Avoid Dextrose and Sodium Chloride Injection in patients with or at risk for fluid and/or solute overloading. If use cannot be avoided, monitor fluid balance, electrolyte concentrations, and acid-base balance as needed and especially during prolonged use.
Refeeding severely undernourished patients may result in the refeeding syndrome that is characterized by the shift of potassium, phosphorus, and magnesium intracellularly as the patient becomes anabolic. Thiamine deficiency and fluid retention may also develop. To prevent these complications, monitor severely undernourished patients and slowly increasing nutrient intake.
- Anaphylactic reaction, hypersensitivity, and chills
- Hyponatremia (applies to solutions containing less than 0.9% Sodium Chloride)
Reactions which may occur because of the solution or the technique of administration include febrile response, infection at the site of injection, venous thrombosis or phlebitis extending from the site of injection, extravasation and hypervolemia.
If an adverse reaction does occur, discontinue the infusion, evaluate the patient, institute appropriate therapeutic countermeasures and save the remainder of the fluid for examination if deemed necessary.
Dextrose and Sodium Chloride Injection can affect glycemic control, vasopressin and fluid and/or electrolyte balance [see Warnings and Precautions (5.2, 5.3, 5.4, 5.5, 5.6)]. Monitor blood glucose concentrations, fluid balance, serum electrolyte concentrations and acid-base balance when using Dextrose and Sodium Chloride Injection in patients treated with other substances that affect glycemic control, vasopressin or fluid and/or electrolyte balance.
Risk Summary
Appropriate administration of Dextrose and Sodium Chloride Injection during pregnancy is not expected to cause adverse developmental outcomes, including congenital malformations. Animal reproduction studies have not been conducted with Dextrose and Sodium Chloride Injection.
The estimated background risk of major birth defects and miscarriage for the indicated population is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2 to 4% and 15 to 20%, respectively.
Risk Summary
Sodium is present in human breast milk. There are no data on the effects of Dextrose and Sodium Chloride Injection on a breastfed infant or the effects on milk production.
The developmental and health benefits of breastfeeding should be considered along with the mother’s clinical need for Dextrose and Sodium Chloride Injection and any potential adverse effects on the breastfed infant from Dextrose and Sodium Chloride Injection or from the underlying maternal condition.
The safety profile of Dextrose and Sodium Chloride Injection in pediatric patients is similar to adults.
Neonates, especially premature infants with low birth weight, are at increased risk of developing hypo- or hyperglycemia and therefore need close monitoring during treatment with intravenous glucose solutions to ensure adequate glycemic control in order to avoid potential long-term adverse effects.
Closely monitor plasma electrolyte concentrations in pediatric patients who may have impaired ability to regulate fluids and electrolytes. In very low birth weight infants, excessive or rapid administration of Dextrose and Sodium Chloride Injection may result in increased serum osmolality and risk of intracerebral hemorrhage.
Children (including neonates and older children) are at increased risk of developing hyponatremia as well as for developing hyponatremic encephalopathy.
Clinical studies of Dextrose and Sodium Chloride Injection did not include sufficient numbers of subjects aged 65 and over to determine whether they respond differently from younger subjects.
Elderly patients are at increased risk of developing hyponatremia as well as for developing hyponatremic encephalopathy [see Warnings and Precautions (5.3)]. Dextrose and Sodium Chloride Injection is known to be substantially excreted by the kidney, and the risk of adverse reactions to this product may be greater in patients with impaired renal function [see Warnings and Precautions (5.2, 5.5)].
Dose selection for an elderly patient should be cautious, starting at the low end of the dosing range, reflecting the greater frequency of decreased hepatic, renal, or cardiac function, and of concomitant disease or other drug therapy.
Administration of Dextrose and Sodium Chloride Injection in patients with renal impairment may result in hyperosmolar hyperglycemic state, hyponatremia, and/or fluid overload. Monitor patients with renal impairment for development of these adverse reactions [see Warnings and Precautions (5.2, 5.3, 5.5, 5.6)].
Excessive administration of Dextrose and Sodium Chloride Injection can cause:
Electrolyte and Fluid Disorders
When assessing an overdose, any additives in the solution must also be considered. Clinically significant overdose of Dextrose and Sodium Chloride Injection may, therefore, constitute a medical emergency. The effects of an overdose may require immediate medical attention and treatment.
Interventions include discontinuation of the infusion, dose reduction, monitoring of fluid balance, electrolyte concentrations and acid-base balance and institution of appropriate corrective measures such as administration of exogenous insulin.
Dextrose and Sodium Chloride Injection, USP is a sterile, nonpyrogenic solution for fluid and electrolyte replenishment and caloric supply in single-dose containers for intravenous administration. It contains no antimicrobial agents. Composition, osmolarity, pH, ionic concentration and caloric content are shown in Table 1.
|
||||||||
Size (mL) |
Composition (g/L) |
*Osmolarity (mOsmol/L) (calc.) |
pH |
Ionic Concentration (mEq/L) |
Caloric Content |
|||
**Dextrose Hydrous, |
Sodium Chloride, USP |
Sodium |
Chloride | |||||
2.5% Dextrose and 0.45% Sodium Chloride Injection, USP |
1000 |
25 |
4.5 |
280 |
4.5 (3.2 to 6.5) |
77 |
77 |
85 |
5% Dextrose and 0.2% Sodium Chloride Injection, USP |
250 500 1000 |
50 |
2 |
321 |
4.0 (3.2 to 6.5) |
34 |
34 |
170 |
5% Dextrose and 0.33% Sodium Chloride Injection, USP |
250 500 1000 |
50 |
3.3 |
365 |
4.0 (3.2 to 6.5) |
56 |
56 |
170 |
5% Dextrose and 0.45% Sodium Chloride Injection, USP |
500 1000 |
50 |
4.5 |
406 |
4.0 (3.2 to 6.5) |
77 |
77 |
170 |
5% Dextrose and 0.9% Sodium Chloride Injection, USP |
500 1000 |
50 |
9 |
560 |
4.0 (3.2 to 6.5) |
154 |
154 |
170 |
Dextrose is derived from corn.
The VIAFLEX Plus plastic container is fabricated from a specially formulated polyvinyl chloride (PL 146 Plastic). The amount of water that can permeate from inside the container into the overwrap is insufficient to affect the solution significantly. Solutions in contact with the plastic container can leach out certain of its chemical components in very small amounts within the expiration period, e.g., di-2-ethylhexyl phthalate (DEHP), up to 5 parts per million. However, the safety of the plastic has been confirmed in tests in animals according to USP biological tests for plastic containers as well as by tissue culture toxicity studies.
Dextrose and Sodium Chloride Injection are clear solutions in 250 mL, 500 mL and 1000 mL single-dose, flexible containers available as follows:
Code |
Size (mL) |
NDC |
Product Name |
2B1024 |
1000 |
0338-0073-04 |
2.5% Dextrose and 0.45% Sodium Chloride Injection, USP |
2B1092 |
250 |
0338-0077-02 |
5% Dextrose and 0.2% Sodium Chloride Injection, USP |
2B1093 |
500 |
0338-0077-03 |
|
2B1094 |
1000 |
0338-0077-04 |
|
2B1083 |
500 |
0338-0081-03 |
5% Dextrose and 0.33% Sodium Chloride Injection, USP |
2B1073 |
500 |
0338-0085-03 |
5% Dextrose and 0.45% Sodium Chloride Injection, USP |
2B1074 |
1000 |
0338-0085-04 |
|
2B1063 |
500 |
0338-0089-03 |
5% Dextrose and 0.9% Sodium Chloride Injection, USP |
2B1064 |
1000 |
0338-0089-04 |
Storage: Avoid excessive heat. Store at room temperature (25°C/77°F); brief exposure up to 40°C/104°F does not adversely affect the product.
Inform patients, caregivers or home healthcare providers of the following risks of Dextrose and Sodium Chloride Injection:
Baxter Healthcare Corporation
Deerfield, IL 60015 USA
Printed in USA
Distributed in Canada by
Baxter Corporation
Mississauga, ON L5N 0C2
07-19-74-506
Baxter, and Viaflex and PL 146 are trademarks of Baxter International Inc.
For Product Information
1-800-933-0303
Container Label
LOT EXP
2B1063
NDC: 0338-0089-03
5% Dextrose and
0.9% Sodium Chloride
Injection USP
500 mL EACH 100 mL CONTAINS 5 g DEXTROSE HYDROUS USP
900 mg SODIUM CHLORIDE USP pH 4.0 (3.2 TO 6.5)
mEq/L SODIUM 154 CHLORIDE 154 HYPERTONIC
OSMOLARITY 560 mOsmol/L (CALC) STERILE
NONPYROGENIC SINGLE DOSE CONTAINER ADDITIVES MAY BE
INCOMPATIBLE CONSULT WITH PHARMACIST IF AVAILABLE
WHEN INTRODUCING ADDITIVES USE ASEPTIC TECHNIQUE MIX
THOROUGHLY DO NOT STORE DOSAGE INTRAVENOUSLY AS
DIRECTED BY A PHYSICIAN SEE DIRECTIONS CAUTIONS
SQUEEZE AND INSPECT INNER BAG WHICH MAINTAINS PRODUCT
STERILITY DISCARD IF LEAKS ARE FOUND MUST NOT BE USED
IN SERIES CONNECTIONS DO NOT USE UNLESS SOLUTION IS
CLEAR RX ONLY STORE UNIT IN MOISTURE BARRIER
OVERWRAP AT ROOM TEMPERATURE (25°C/77°F) UNTIL READY
TO USE AVOID EXCESSIVE HEAT SEE INSERT
VIAFLEX CONTAINER PL 146 PLASTIC
BAXTER VIAFLEX AND PL 146 ARE TRADEMARKS OF
BAXTER INTERNATIONAL INC
FOR PRODUCT INFORMATION 1-800-933-0303
BAXTER Logo
BAXTER HEALTHCARE CORPORATION
DEERFIELD IL 60015 USA
MADE IN USA
1
2
3
4
Carton Label
2B1063Q 24-500 ML
VIAFLEX® CONTAINER
5% DEXTROSE AND
0.9% SODIUM CHLORIDE INJ, USP
EXP
XXXXX
SECONDARY BAR CODE
(17) YYMM00 (10) XXXXX
LOT
XXXXX
PRIMARY BAR CODE
(01) 50303380089036
Container Label
LOT EXP
2B1024
NDC: 0338-0073-04
2.5% Dextrose
and 0.45%
Sodium Chloride
Injection USP
1000 mL
EACH 100 mL CONTAINS 2.5 g DEXTROSE HYDROUS USP
450 mg SODIUM CHLORIDE USP pH 4.0 (3.2 TO 6.5)
mEq/L SODIUM 77 CHLORIDE 77 OSMOLARITY 280
mOsmol/L (CALC) STERILE NONPYROGENIC SINGLE
DOSE CONTAINER ADDITIVES MAY BE INCOMPATIBLE
CONSULT WITH PHARMACIST IF AVAILABLE WHEN
INTRODUCING ADDITIVES USE ASEPTIC TECHNIQUE MIX
THOROUGHLY DO NOT STORE DOSAGE INTRAVENOUSLY
AS DIRECTED BY A PHYSICIAN SEE DIRECTIONS CAUTIONS
SQUEEZE AND INSPECT INNER BAG WHICH MAINTAINS
PRODUCT STERILITY DISCARD IF LEAKS ARE FOUND MUST
NOT BE USED IN SERIES CONNECTIONS DO NOT USE UNLESS
SOLUTION IS CLEAR RX ONLY STORE UNIT IN MOISTURE
BARRIER OVERWRAP AT ROOM TEMPERATURE (25°C/77°F)
UNTIL READY TO USE AVOID EXCESSIVE HEAT SEE INSERT
VIAFLEX CONTAINER PL 146 PLASTIC
BAXTER VIAFLEX AND PL 146 ARE TRADEMARKS OF
BAXTER INTERNATIONAL INC
FOR PRODUCT INFORMATION 1-800-933-0303
Baxter Logo
BAXTER HEALTHCARE CORPORATION
DEERFIELD IL 60015 USA
MADE IN USA
1
2
3
4
5
6
7
8
9
Carton Label
2B1024X 14-1000 ML
VIAFLEX® CONTAINER
2.5% DEXTROSE AND
0.45% SODIUM CHLORIDE INJ, USP
EXP
XXXXX
SECONDARY BAR CODE
(17) XXXXX (10) XXXXX
LOT
XXXXX
PRIMARY BAR CODE
(01) 50303380073042
Container Label
LOT EXP
2B1092
NDC: 0338-0077-02
5% Dextrose and
0.2% Sodium Chloride
Injection USP
250 mL EACH 100 mL CONTAINS
5 g DEXTROSE HYDROUS
USP 200 mg SODIUM CHLORIDE USP
pH 4.0 (3.2 TO 6.5) mEq/L SODIUM 34
CHLORIDE 34 OSMOLARITY 321 mOsmol/L
(CALC) STERILE NONPYROGENIC SINGLE
DOSE CONTAINER ADDITIVES MAY BE
INCOMPATIBLE CONSULT WITH PHARMACIST
IF AVAILABLE WHEN INTRODUCING ADDITIVES
USE ASEPTIC TECHNIQUE MIX THOROUGHLY
DO NOT STORE DOSAGE INTRAVENOUSLY AS
DIRECTED BY A PHYSICIAN SEE DIRECTIONS
CAUTIONS SQUEEZE AND INSPECT INNER
BAG WHICH MAINTAINS PRODUCT STERILITY
DISCARD IF LEAKS ARE FOUND MUST NOT BE
USED IN SERIES CONNECTIONS DO NOT
USE UNLESS SOLUTION IS CLEAR RX
ONLY STORE UNIT IN MOISTURE BARRIER
OVERWRAP AT ROOM TEMPERATURE
(25°C/77°F) UNTIL READY TO USE AVOID
EXCESSIVE HEAT SEE INSERT
VIAFLEX CONTAINER PL 146 PLASTIC
BAXTER VIAFLEX AND PL 146 ARE
TRADEMARKS OF BAXTER INTERNATIONAL INC
FOR PRODUCT INFORMATION
1-800-933-0303
BAXTER Logo
BAXTER HEALTHCARE CORPORATION
DEERFIELD IL 60015 USA
MADE IN USA
50
100
150
200
Carton Label
Carton Label
2B1092Q 36-250 ML
VIAFLEX® CONTAINER
5% DEXTROSE AND
0.2% SODIUM CHLORIDE INJ, USP
EXP
XXXXX
SECONDARY BAR CODE
(17) YYMM00 (10) XXXXX
LOT
XXXXX
PRIMARY BAR CODE
(01) 50303380077026
Container Label
Container Label
LOT EXP
2B1083
NDC: 0338-0081-03
5% Dextrose and
0.33% Sodium Chloride
Injection USP
500 mL
EACH 100 mL CONTAINS 5 g DEXTROSE HYDROUS USP
330 mg SODIUM CHLORIDE USP pH 4.0 (3.2 TO 6.5)
mEq/L SODIUM 56 CHLORIDE 56 OSMOLARITY 356
mOsmol/L (CALC) STERILE NONPYROGENIC SINGLE DOSE
CONTAINER ADDITIVES MAY BE INCOMPATIBLE CONSULT WITH
PHARMACIST IF AVAILABLE WHEN INTRODUCING ADDITIVES USE
ASEPTIC TECHNIQUE MIX THOROUGHLY DO NOT STORE
DOSAGE INTRAVENOUSLY AS DIRECTED BY A PHYSICIAN SEE
DIRECTIONS CAUTIONS SQUEEZE AND INSPECT INNER BAG
WHICH MAINTAINS PRODUCT STERILITY DISCARD IF LEAKS ARE
FOUND MUST NOT BE USED IN SERIES CONNECTIONS DO NOT
USE UNLESS SOLUTION IS CLEAR RX ONLY STORE UNIT IN
MOISTURE BARRIER OVERWRAP T ROOM TEMPERATURE
(25°C/77°F) UNTIL READY TO USE AVOID EXCESSIVE HEAT
SEE INSERT
VIAFLEX CONTAINER PL 146 PLASTIC
BAXTER VIAFLEX AND PL 146 ARE TRADEMARKS OF
BAXTER INTERNATIONAL INC
FOR PRODUCT INFORMATION 1-800-933-0303
Baxter Logo
BAXTER HEALTHCARE CORPORATION
DEERFIELD IL 60015 USA
MADE IN USA
07-25-34-096
1
2
3
4
Carton Label
2B1083Q 24-500 ML
VIAFLEX® CONTAINER
5% DEXTROSE AND
0.33% SODIUM CHLORIDE INJ, USP
EXP
XXXXX
SECONDARY BAR CODE
(17) XXXXX (10) XXXXX
LOT
XXXXX
PRIMARY BAR CODE
(01) 50303380081030
Container Label
LOT EXP
2B1073
NDC: 0338-0085-03
5% Dextrose and
0.45% Sodium Chloride
Injection USP
500 mL
EACH 100 mL CONTAINS 5 g DEXTROSE HYDROUS USP
450 mg SODIUM CHLORIDE USP pH 4.0 (3.2 TO 6.5)
mEq/L SODIUM 77 CHLORIDE 77 HYPERTONIC OSMOLARITY
406 mOsmol/L (CALC) STERILE NONPYROGENIC SINGLE
DOSE CONTAINER ADDITIVES MAY BE INCOMPATIBLE CONSULT
WITH PHARMACIST IF AVAILABLE WHEN INTRODUCING ADDITIVES
USE ASEPTIC TECHNIQUE MIX THOROUGHLY DO NOT STORE
DOSAGE INTRAVENOUSLY AS DIRECTED BY A PHYSICIAN SEE
DIRECTIONS CAUTIONS SQUEEZE AND INSPECT INNER BAG
WHICH MAINTAINS PRODUCT STERILITY DISCARD IF LEAKS ARE
FOUND MUST NOT BE USED IN SERIES CONNECTIONS DO NOT
USE UNLESS SOLUTION IS CLEAR RX ONLY STORE UNIT IN
MOISTURE BARRIER OVERWRAP AT ROOM TEMPERATURE
(25°C/77°F) UNTIL READY TO USE AVOID EXCESSIVE HEAT
SEE INSERT
VIAFLEX CONTAINER PL 146 PLASTIC
BAXTER VIAFLEX AND PL 146 ARE
TRADEMARKS OF BAXTER INTERNATIONAL INC
FOR PRODUCT INFORMATION 1-800-933-0303
BAXTER Logo
BAXTER HEALTHCARE CORPORATION
DEERFIELD IL 60015 USA
MADE IN USA
1
2
3
4
Carton Label
2B1073Q 24-500 ML
VIAFLEX® CONTAINER
5% DEXTROSE AND
0.45% SODIUM CHLORIDE INJ, USP
EXP
XXXXX
SECONDARY BAR CODE
(17) YYMM00 (10) XXXXX
LOT
XXXXX
PRIMARY BAR CODE
(01) 50303380085038
DEXTROSE AND SODIUM CHLORIDE
dextrose and sodium chloride injection, solution |
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
DEXTROSE AND SODIUM CHLORIDE
dextrose and sodium chloride injection, solution |
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
|
DEXTROSE AND SODIUM CHLORIDE
dextrose and sodium chloride injection, solution |
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
DEXTROSE AND SODIUM CHLORIDE
dextrose and sodium chloride injection, solution |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
DEXTROSE AND SODIUM CHLORIDE
dextrose and sodium chloride injection, solution |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
Labeler - Baxter Healthcare Corporation (005083209) |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Baxter Healthcare Corporation | 059140764 | MANUFACTURE(0338-0073, 0338-0077, 0338-0081, 0338-0085, 0338-0089) , ANALYSIS(0338-0073, 0338-0077, 0338-0081, 0338-0085, 0338-0089) , LABEL(0338-0073, 0338-0077, 0338-0081, 0338-0085, 0338-0089) , PACK(0338-0073, 0338-0077, 0338-0081, 0338-0085, 0338-0089) , STERILIZE(0338-0073, 0338-0077, 0338-0081, 0338-0085, 0338-0089) |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Baxter Healthcare Corporation | 194684502 | ANALYSIS(0338-0073, 0338-0077, 0338-0081, 0338-0085, 0338-0089) |