MERILOG by is a Prescription medication manufactured, distributed, or labeled by Sanofi-Aventis U.S. LLC, Sanofi-Aventis Deutschland GmbH. Drug facts, warnings, and ingredients follow.
MERILOG is rapid acting human insulin analog indicated to improve glycemic control in adults and pediatric patients with diabetes mellitus (1).
See Full Prescribing Information for important preparation, administration, and dosage instructions (2.1, 2.2, 2.3, 2.4, 2.5).
Injection: 100 units/mL (U-100) of insulin aspart-szjj available as: (3)
Adverse reactions observed with insulin aspart products include: hypoglycemia, allergic reactions, local injection site reactions, lipodystrophy, rash, and pruritus (6).
To report SUSPECTED ADVERSE REACTIONS, contact sanofi-aventis at 1-800-633-1610 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
See 17 for PATIENT COUNSELING INFORMATION and FDA-approved patient labeling.
Revised: 2/2025
Subcutaneous Injection
MERILOG is contraindicated:
MERILOG SoloStar prefilled pen should never be shared between patients, even if the needle is changed. Patients using MERILOG vials must never share needles or syringes with another person. Sharing poses a risk for transmission of blood-borne pathogens.
Changes in an insulin regimen (e.g., insulin strength, manufacturer, type, injection site or method of administration) may affect glycemic control and predispose to hypoglycemia [see Warnings and Precautions (5.3)] or hyperglycemia. Repeated insulin injections into areas of lipodystrophy or localized cutaneous amyloidosis have been reported to result in hyperglycemia; and a sudden change in the injection site (to an unaffected area) has been reported to result in hypoglycemia [see Adverse Reactions (6.1, 6.3)].
Make any changes to a patient's insulin regimen under close medical supervision with increased frequency of blood glucose monitoring. Advise patients who have repeatedly injected into areas of lipodystrophy or localized cutaneous amyloidosis to change the injection site to unaffected areas and closely monitor for hypoglycemia. For patients with type 2 diabetes, dosage adjustments of concomitant anti-diabetic products may be needed.
Hypoglycemia is the most common adverse reaction of all insulins, including insulin aspart products. Severe hypoglycemia can cause seizures, may lead to unconsciousness, may be life threatening or cause death. Hypoglycemia can impair concentration ability and reaction time; this may place an individual and others at risk in situations where these abilities are important (e.g., driving or operating other machinery).
Hypoglycemia can happen suddenly and symptoms may differ in each individual and change over time in the same individual. Symptomatic awareness of hypoglycemia may be less pronounced in patients with longstanding diabetes in patients with diabetic nerve disease, in patients using medications that block the sympathetic nervous system (e.g., beta-blockers) [see Drug Interactions (7)], or in patients who experience recurrent hypoglycemia.
Risk Factors for Hypoglycemia
The risk of hypoglycemia after an injection is related to the duration of action of the insulin and, in general, is highest when the glucose lowering effect of the insulin is maximal. As with all insulins, the glucose lowering effect time course of insulin aspart products may vary in different individuals or at different times in the same individual and depends on many conditions, including the area of injection as well as the injection site blood supply and temperature [see Clinical Pharmacology (12.2)]. Other factors which may increase the risk of hypoglycemia include changes in meal pattern (e.g., macronutrient content or timing of meals), changes in level of physical activity, or changes to concomitantly administered medication [see Drug Interactions (7)]. Patients with renal or hepatic impairment may be at higher risk of hypoglycemia [see Use in Specific Populations (8.6, 8.7)].
Patients and caregivers must be educated to recognize and manage hypoglycemia. Self-monitoring of blood glucose plays an essential role in the prevention and management of hypoglycemia; increased frequency of blood glucose monitoring is recommended. In patients at higher risk for hypoglycemia and patients who have reduced symptomatic awareness of hypoglycemia, increased frequency of blood glucose monitoring is recommended.
Accidental mix-ups between insulin products have been reported. To avoid medication errors between MERILOG and other insulins, instruct patients to always check the insulin label before each injection.
Severe, life-threatening, generalized allergy, including anaphylaxis, can occur with insulins, including insulin aspart products. If hypersensitivity reactions occur, discontinue MERILOG; treat per standard of care and monitor until symptoms and signs resolve [see Adverse Reactions (6)]. MERILOG is contraindicated in patients who have had hypersensitivity reactions to insulin aspart products or any of the excipients in MERILOG [see Contraindications (4)].
All insulins, including insulin aspart products, can cause a shift in potassium from the extracellular to intracellular space, possibly leading to hypokalemia. Untreated hypokalemia may cause respiratory paralysis, ventricular arrhythmia, and death. Monitor potassium levels in patients at risk for hypokalemia if indicated (e.g., patients using potassium-lowering medications, patients taking medications sensitive to serum potassium concentration).
Thiazolidinediones (TZDs), which are peroxisome proliferator-activated receptor (PPAR)-gamma agonists, can cause dose-related fluid retention, particularly when used in combination with insulin. Fluid retention may lead to or exacerbate heart failure. Patients treated with insulin, including MERILOG, and a PPAR-gamma agonist should be observed for signs and symptoms of heart failure. If heart failure develops, it should be managed according to current standards of care, and discontinuation or dose reduction of the PPAR-gamma agonist must be considered.
The following adverse reactions are also discussed elsewhere:
Because clinical trials are conducted under widely varying designs, the adverse reaction rates reported in one clinical trial may not be easily compared to those rates reported in another clinical trial, and may not reflect the rates actually observed in clinical practice. The safety of insulin aspart was evaluated in two treat-to-target trials of 6 months duration, conducted in patients with type 1 diabetes or type 2 diabetes [see Clinical Studies (14)].
The data in Table 1 reflect the exposure of 596 patients with type 1 diabetes to insulin aspart in one clinical trial with a mean exposure duration to insulin aspart of 24 weeks. The mean age was 39 years. Fifty-one percent were male, 94% were Caucasian, 2% were Black and 4% were other races. The mean body mass index (BMI) was 25.6 kg/m2. The mean duration of diabetes was 15.7 years and the mean HbA1c at baseline was 7.9%.
The data in Table 2 reflect the exposure of 91 patients with type 2 diabetes to insulin aspart in one clinical trial with a mean exposure duration to insulin aspart of 24 weeks. The mean age was 57 years. Sixty-three percent were male, 76% were Caucasian, 9% were Black and 15% were other races. The mean BMI was 29.7 kg/m2. The mean duration of diabetes was 12.7 years and the mean HbA1c at baseline was 8.1%.
Common adverse reactions were defined as events that occurred in ≥5%, excluding hypoglycemia, of the population studied. Common adverse events that occurred at the same rate or greater for insulin aspart-treated patients than in comparator-treated patients during clinical trials in patients with type 1 diabetes mellitus and type 2 diabetes mellitus (other than hypoglycemia) are listed in Table 1 and Table 2, respectively.
Insulin aspart + NPH (%) (n= 596) | Regular Human Insulin + NPH (%) (n= 286) |
|
---|---|---|
Headache | 12 | 10 |
Injury accidental | 11 | 10 |
Nausea | 7 | 5 |
Diarrhea | 5 | 3 |
Insulin aspart + NPH (%) (n= 91) | Human Regular Insulin + NPH (%) (n= 91) |
|
---|---|---|
Hyporeflexia | 11 | 7 |
Onychomycosis | 10 | 5 |
Sensory disturbance | 9 | 7 |
Urinary tract infection | 8 | 7 |
Chest pain | 5 | 3 |
Headache | 5 | 3 |
Skin disorder | 5 | 2 |
Abdominal pain | 5 | 1 |
Sinusitis | 5 | 1 |
Severe Hypoglycemia
Hypoglycemia is the most commonly observed adverse reaction in patients using insulin, including insulin aspart products [see Warnings and Precautions (5.3)]. The rates of reported hypoglycemia depend on the definition of hypoglycemia used, diabetes type, insulin dose, intensity of glucose control, background therapies, and other intrinsic and extrinsic patient factors. For these reasons, comparing rates of hypoglycemia in clinical trials for insulin aspart with the incidence of hypoglycemia for other products may be misleading and also, may not be representative of hypoglycemia rates that will occur in clinical practice.
Severe hypoglycemia was defined as hypoglycemia associated with central nervous system symptoms and requiring the intervention of another person or hospitalization. The incidence of severe hypoglycemia in:
Allergic Reactions
Some patients taking insulin, including insulin aspart products have experienced erythema, local edema, and pruritus at the site of injection. These conditions were usually self-limiting. Severe cases of generalized allergy (anaphylaxis) have been reported.
Adverse Reactions Associated with Insulin Initiation and Glucose Control Intensification
Intensification or rapid improvement in glucose control has been associated with a transitory, reversible ophthalmologic refraction disorder, worsening of diabetic retinopathy, and acute painful peripheral neuropathy. However, long-term glycemic control decreases the risk of diabetic retinopathy and neuropathy.
Lipodystrophy
Administration of insulin, including insulin aspart products subcutaneously, has resulted in lipoatrophy (depression in the skin) or lipohypertrophy (enlargement or thickening of tissue) in some patients [see Dosage and Administration (2.2)].
As with all therapeutic proteins, there is potential for immunogenicity. The detection of antibody formation is highly dependent on the sensitivity and specificity of the assay. Additionally, the observed incidence of antibody (including neutralizing antibody) positivity in an assay may be influenced by several factors including assay methodology, sample handling, timing of sample collection, concomitant medications, and underlying disease. For these reasons, comparison of the incidence of antibodies in the studies described below with the incidence of antibodies in other studies or to other insulin aspart products may be misleading.
In a 6-month study with a 6-month extension in adult subjects with type 1 diabetes, 99.8% of patients who received insulin aspart were positive for anti-insulin antibodies (AIA) at least once during the study, including 97.2% that were positive at baseline. A total of 92.1% of patients who received insulin aspart were positive for anti-drug antibodies (ADA) at least once during the study, including 64.6% that were positive at baseline.
In a phase 3 type 1 diabetes clinical trial of insulin aspart, initial increase in titers of antibodies to insulin, followed by a decrease to baseline values, was observed in regular human insulin and insulin aspart treatment groups with similar incidences. These antibodies did not cause deterioration in glycemic control or necessitate increases in insulin dose.
The following adverse reactions have been identified during post-approval use of insulin aspart products. Because these adverse reactions are reported voluntarily from a population of uncertain size, it is generally not possible to reliably estimate their frequency or establish a causal relationship to drug exposure.
Medication errors have been reported in which other insulins have been accidentally substituted for insulin aspart products.
Localized cutaneous amyloidosis at the injection site has occurred with insulin aspart products. Hyperglycemia has been reported with repeated insulin injections into areas of localized cutaneous amyloidosis; hypoglycemia has been reported with a sudden change to an unaffected injection site.
The table below presents clinically significant drug interactions with MERILOG.
Drugs That May Increase the Risk of Hypoglycemia | |
---|---|
Drugs: | Antidiabetic agents, ACE inhibitors, angiotensin II receptor blocking agents, disopyramide, fibrates, fluoxetine, monoamine oxidase inhibitors, pentoxifylline, pramlintide, salicylates, somatostatin analog (e.g., octreotide), and sulfonamide antibiotics. |
Intervention: | Dose adjustment and increased frequency of glucose monitoring may be required when MERILOG is concomitantly administered with these drugs. |
Drugs That May Decrease the Blood Glucose Lowering Effect of MERILOG | |
Drugs: | Atypical antipsychotics (e.g., olanzapine and clozapine), corticosteroids, danazol, diuretics, estrogens, glucagon, isoniazid, niacin, oral contraceptives, phenothiazines, progestogens (e.g., in oral contraceptives), protease inhibitors, somatropin, sympathomimetic agents (e.g., albuterol, epinephrine, terbutaline), and thyroid hormones. |
Intervention: | Dose adjustment and increased frequency of glucose monitoring may be required when MERILOG is concomitantly administered with these drugs. |
Drugs That May Increase or Decrease the Blood Glucose Lowering Effect of MERILOG | |
Drugs: | Alcohol, beta-blockers, clonidine, and lithium salts. Pentamidine may cause hypoglycemia, which may sometimes be followed by hyperglycemia. Pentamidine may cause hypoglycemia, which may sometimes be followed by hyperglycemia. |
Intervention: | Dose adjustment and increased frequency of glucose monitoring may be required when MERILOG is concomitantly administered with these drugs. |
Drugs That May Blunt Signs and Symptoms of Hypoglycemia | |
Drugs: | Beta-blockers, clonidine, guanethidine and reserpine |
Intervention: | Increased frequency of glucose monitoring may be required when MERILOG is concomitantly administered with these drugs. |
Risk Summary
Available information from published randomized controlled trials with insulin aspart products use during the second trimester of pregnancy have not reported an association with insulin aspart products and major birth defects or adverse maternal or fetal outcomes [see Data]. There are risks to the mother and fetus associated with poorly controlled diabetes in pregnancy [see Clinical Considerations].
In animal reproduction studies, administration of subcutaneous insulin aspart to pregnant rats and rabbits during the period of organogenesis did not cause adverse developmental effects at exposures 8-times and equal to the human subcutaneous dose of 1 unit/kg/day, respectively. Pre- and post-implantation losses and visceral/skeletal abnormalities were seen at higher exposures, which are considered secondary to maternal hypoglycemia. These effects were similar to those observed in rats administered regular human insulin [see Data].
In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2 to 4% and 15 to 20%, respectively. The estimated background risk of major birth defects is 6 to 10% in women with pre-gestational diabetes with a periconceptual HbA1c >7% and has been reported to be as high as 20 to 25% in women with a periconceptual HbA1c >10%. The estimated background risk of miscarriage for the indicated population is unknown.
Disease-Associated Maternal and/or Embryo-Fetal Risk
Poorly controlled diabetes in pregnancy increases the maternal risk for diabetic ketoacidosis, preeclampsia, spontaneous abortions, preterm delivery, and delivery complications. Poorly controlled diabetes increases the fetal risk for major birth defects, stillbirth, and macrosomia related morbidity.
Human Data
Published data from 5 randomized controlled trials of 441 pregnant women with diabetes mellitus treated with insulin aspart products during the late 2nd trimester of pregnancy did not identify an association of insulin aspart products with major birth defects or adverse maternal or fetal outcomes. However, these studies cannot definitely establish the absence of any risk because of methodological limitations, including a variable duration of treatment and small size of the majority of the trials.
Animal Data
Fertility, embryo-fetal and pre- and postnatal development studies have been performed with insulin aspart and regular human insulin in rats and rabbits. In a combined fertility and embryo-fetal development study in rats, insulin aspart was administered before mating, during mating, and throughout pregnancy. Further, in a pre- and postnatal development study insulin aspart was given throughout pregnancy and during lactation to rats. In an embryo-fetal development study insulin aspart was given to female rabbits during organogenesis. The effects of insulin aspart did not differ from those observed with subcutaneous regular human insulin. Insulin aspart, like human insulin, caused pre- and post-implantation losses and visceral/skeletal abnormalities in rats at a dose of 200 units/kg/day (approximately 32 times the human subcutaneous dose of 1 unit/kg/day, based on human exposure equivalents) and in rabbits at a dose of 10 units/kg/day (approximately three times the human subcutaneous dose of 1 unit/kg/day, based on human exposure equivalents). No significant effects were observed in rats at a dose of 50 units/kg/day and in rabbits at a dose of 3 units/kg/day. These doses are approximately 8 times the human subcutaneous dose of 1 unit/kg/day for rats and equal to the human subcutaneous dose of 1 unit/kg/day for rabbits, based on human exposure equivalents. The effects are considered secondary to maternal hypoglycemia.
Risk Summary
There are no data on the presence of insulin aspart products in human milk, the effects on the breastfed infant, or the effect on milk production. One small published study reported that exogenous insulin, including insulin aspart, was present in human milk. However, there is insufficient information to determine the effects of insulin aspart products on the breastfed infant. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for MERILOG, and any potential adverse effects on the breastfed infant from MERILOG, or from the underlying maternal condition.
The safety and effectiveness of MERILOG to improve glycemic control have been established in pediatric patients with diabetes mellitus. Use of MERILOG for this indication is supported by evidence from an adequate and well-controlled study of insulin aspart in 283 pediatric patients with type 1 diabetes mellitus aged 6 to 18 years and from studies in adults with diabetes mellitus [see Adverse Reactions (6.1), Clinical Pharmacology (12.3), and Clinical Studies (14)].
Of the total number of patients (n=1,375) treated with insulin aspart in 3 controlled clinical studies, 2.6% (n=36) were 65 years of age or over. One-half of these patients had type 1 diabetes (18/1285) and the other half had type 2 diabetes (18/90). The HbA1c response to insulin aspart, as compared to regular human insulin, did not differ by age.
Patients with renal impairment may be at increased risk of hypoglycemia and may require more frequent MERILOG dose adjustment and more frequent blood glucose monitoring [see Warnings and Precautions (5.3) and Clinical Pharmacology (12.3)].
Patients with hepatic impairment may be at increased risk of hypoglycemia and may require more frequent MERILOG dose adjustment and more frequent blood glucose monitoring [see Warnings and Precautions (5.3) and Clinical Pharmacology (12.3)].
Excess insulin administration may cause hypoglycemia and hypokalemia [see Warnings and Precautions (5.3, 5.6)]. Mild episodes of hypoglycemia usually can be treated with oral glucose. Adjustments in drug dosage, meal patterns, or exercise may be needed. More severe episodes with coma, seizure, or neurologic impairment may be treated with intramuscular/subcutaneous glucagon or concentrated intravenous glucose. Sustained carbohydrate intake and observation may be necessary because hypoglycemia may recur after apparent clinical recovery. Hypokalemia must be corrected appropriately.
Insulin aspart-szjj is a rapid-acting human insulin analog homologous with regular human insulin with the exception of a single substitution of the amino acid proline by aspartic acid in position B28, and is produced by recombinant DNA technology utilizing Escherichia coli. Insulin aspart-szjj has a molecular weight of 5825.8 Da.
MERILOG (insulin aspart-szjj) injection is a sterile, clear, and colorless solution for subcutaneous use. Each mL contains 100 units of insulin aspart-szjj and the inactive ingredients: 1.72 mg metacresol, 1.50 mg phenol, 0.02 mg polysorbate 20, 6.80 mg sodium chloride, 0.04 mg zinc chloride and Water for Injection, USP. MERILOG has a pH of 7.0–7.8. Hydrochloric acid and/or sodium hydroxide may be added to adjust pH.
The primary activity of insulin, including insulin aspart products is the regulation of glucose metabolism. Insulin and its analogs lower blood glucose by stimulating peripheral glucose uptake, especially by skeletal muscle and fat, and by inhibiting hepatic glucose production. Insulin inhibits lipolysis and proteolysis, and enhances protein synthesis.
Pharmacodynamics of Insulin Aspart After Subcutaneous Administration
The pharmacodynamic profile of insulin aspart given subcutaneously in 22 patients with type 1 diabetes is shown in Figure 1. The maximum glucose-lowering effect of insulin aspart occurred between 1 and 3 hours after subcutaneous injection (0.15 units/kg). The duration of action for insulin aspart is 3 to 5 hours. The time course of action of insulin and insulin analogs such as insulin aspart products may vary considerably in different individuals or within the same individual. The parameters of insulin aspart activity (time of onset, peak time and duration) as designated in Figure 1 should be considered only as general guidelines. The rate of insulin absorption and onset of activity is affected by the site of injection, exercise, and other variables [see Warnings and Precautions (5.3)].
Figure 1. Serial mean serum glucose collected up to 6 hours following a single 0.15 units/kg pre-meal dose of insulin aspart (solid curve) or regular human insulin (hatched curve) injected immediately before a meal in 22 patients with type 1 diabetes.
Pharmacokinetics of subcutaneous administration of insulin aspart is presented below.
Absorption and Bioavailability
In studies in healthy volunteers (total n=107) and patients with type 1 diabetes (total n=40), the median time to maximum concentration of insulin aspart in these trials was 40 to 50 minutes versus 80 to 120 minutes, for regular human insulin respectively.
The relative bioavailability of insulin aspart (0.15 units/kg) compared to regular human insulin indicates that the two insulins are absorbed to a similar extent.
In a clinical trial in patients with type 1 diabetes, insulin aspart and regular human insulin, both administered subcutaneously at a dose of 0.15 units/kg body weight, reached mean maximum concentrations of 82 and 36 mU/L, respectively.
Distribution
Insulin aspart has a low binding affinity to plasma proteins (<10%), similar to that seen with regular human insulin.
Figure 2. Serial mean serum free insulin concentration collected up to 6 hours following a single 0.15 units/kg pre-meal dose of insulin aspart (solid curve) or regular human insulin (hatched curve) injected immediately before a meal in 22 patients with type 1 diabetes.
Metabolism and Elimination
After subcutaneous administration in normal male volunteers (n=24), insulin aspart was eliminated with an average apparent half-life of 81 minutes.
Specific Populations
Pediatric Patients: The pharmacokinetic and pharmacodynamic properties of insulin aspart and regular human insulin were evaluated in a single dose study in 18 pediatric patients with type 1 diabetes in 2 age groups: 6–12 years, n=9 and 13–17 years (Tanner grade ≥2), n=9. The relative differences in pharmacokinetics and pharmacodynamics in the pediatric patients with type 1 diabetes in both age groups between insulin aspart and regular human insulin were similar to those in healthy adult subjects and adults with type 1 diabetes.
Geriatric Patients: The pharmacokinetic and pharmacodynamic properties of insulin aspart and regular human insulin were investigated in a single dose study in 18 subjects with type 2 diabetes who were ≥65 years of age. The relative differences in pharmacokinetics and pharmacodynamics in geriatric patients with type 2 diabetes between insulin aspart and regular human insulin were similar to those in younger adults.
Male and Female Patients: In healthy volunteers given a single subcutaneous dose of insulin aspart 0.06 units/kg, no difference in insulin aspart levels was seen between males and females based on comparison of AUC(0–10h) or Cmax.
Obese Patients: A single subcutaneous dose of 0.1 units/kg insulin aspart was administered in a study of 23 patients with type 1 diabetes and a wide range of body mass index (BMI, 22–39 kg/m2). The pharmacokinetic parameters, AUC and Cmax, of insulin aspart were generally unaffected by BMI in the different groups – BMI 19–23 kg/m2 (n=4); BMI 23–27 kg/m2 (n=7); BMI 27–32 kg/m2 (n=6) and BMI >32 kg/m2 (n=6). Clearance of insulin aspart was reduced by 28% in patients with BMI >32 kg/m2 compared to patients with BMI <23 kg/m2.
Patients with Renal Impairment: A single subcutaneous dose of 0.08 units/kg insulin aspart was administered in a study to subjects with either normal renal function (n=6) creatinine clearance (CLcr) (>80 ml/min) or mild (n=7; CLcr=50–80 ml/min), moderate (n=3; CLcr=30–50 ml/min) or severe (but not requiring hemodialysis) (n=2; CLcr = <30 ml/min) renal impairment. In this study, there was no apparent effect of creatinine clearance values on AUC and Cmax of insulin aspart.
Patients with Hepatic Impairment: A single subcutaneous dose of 0.06 units/kg insulin aspart was administered in an open-label, single-dose study of 24 subjects (n=6/group) with different degree of hepatic impairment (mild, moderate and severe) having Child-Pugh Scores ranging from 0 (healthy volunteers) to 12 (severe hepatic impairment). In this study, there was no correlation between the degree of hepatic impairment and any insulin aspart pharmacokinetic parameter.
Standard 2-year carcinogenicity studies in animals have not been performed to evaluate the carcinogenic potential of insulin aspart products. In 52-week studies, Sprague-Dawley rats were dosed subcutaneously with insulin aspart at 10, 50, and 200 units/kg/day (approximately 2, 8, and 32 times the human subcutaneous dose of 1.0 units/kg/day, based on units/body surface area, respectively). At a dose of 200 units/kg/day, insulin aspart increased the incidence of mammary gland tumors in females when compared to untreated controls. The relevance of these findings to humans is unknown.
Insulin aspart was not genotoxic in the following tests: Ames test, mouse lymphoma cell forward gene mutation test, human peripheral blood lymphocyte chromosome aberration test, in vivo micronucleus test in mice, and in ex vivo UDS test in rat liver hepatocytes.
In fertility studies in male and female rats, at subcutaneous doses up to 200 units/kg/day (approximately 32 times the human subcutaneous dose, based on units/body surface area), no direct adverse effects on male and female fertility, or general reproductive performance of animals was observed.
The safety and effectiveness of subcutaneous insulin aspart were compared to regular human insulin in 596 type 1 diabetes adult, 187 pediatric type 1 diabetes, and 91 adult type 2 diabetes patients using NPH as basal insulin (see Tables 3, 4, 5). The reduction in glycated hemoglobin (HbA1c) was similar to regular human insulin.
Type 1 Diabetes - Adults (see Table 3)
Two 24-week, open-label, active-controlled studies were conducted to compare the safety and efficacy of insulin aspart to regular human insulin injection in adult patients with type 1 diabetes. Because the two study designs and results were similar, data are shown for only one study (see Table 3).
The mean age of the trial population was 39 years and mean duration of diabetes was 15.7 years. Fifty-one percent were male. Ninety-four percent were Caucasian, 2% were Black and 4% were Other. The mean BMI was approximately 25.6 kg/m2.
Insulin aspart was administered by subcutaneous injection immediately prior to meals and regular human insulin was administered by subcutaneous injection 30 minutes before meals. NPH insulin was administered as the basal insulin in either single or divided daily doses. Changes in HbA1c were comparable for the two treatment regimens in this study (Table 3).
Insulin aspart + NPH (n=596) | Regular Human Insulin + NPH (n=286) |
|
---|---|---|
|
||
Baseline HbA1c (%)* | 7.9 ± 1.1 | 8.0 ± 1.2 |
Change from Baseline HbA1c (%) | -0.1 ± 0.8 | 0.0 ± 0.8 |
Treatment Difference in HbA1c, Mean (95% confidence interval) | -0.2 (-0.3, -0.1) |
Type 1 Diabetes – Pediatric (see Table 4)
The efficacy of insulin aspart to improve glycemic control in pediatric patients with type 1 diabetes mellitus is based on an adequate and well-controlled trial of regular human insulin in pediatric patients with type 1 diabetes mellitus (Table 4). This 24-week, parallel-group study of pediatric patients with type 1 diabetes (n=283), aged 6 to 18 years, compared two subcutaneous multiple-dose treatment regimens: insulin aspart (n=187) or regular human insulin (n=96). NPH insulin was administered as the basal insulin. Similar effects on HbA1c were observed in both treatment groups (Table 4).
Subcutaneous administration of insulin aspart and regular human insulin have also been compared in pediatric patients with type 1 diabetes (n=26) aged 2 to 6 years with similar effects on HbA1c.
Insulin aspart + NPH (n=187) | Regular Human Insulin + NPH (n=96) |
|
---|---|---|
|
||
Baseline HbA1c (%)* | 8.3 ± 1.2 | 8.3 ± 1.3 |
Change from Baseline HbA1c (%) | 0.1 ± 1.0 | 0.1 ± 1.1 |
Treatment Difference in HbA1c, Mean (95% confidence interval) | -0.2 (-0.5, 0.1) |
Type 2 Diabetes - Adults (see Table 5)
One six-month, open-label, active-controlled study was conducted to compare the safety and efficacy of insulin aspart to regular human insulin in patients with type 2 diabetes (Table 5).
The mean age of the trial population was 56.6 years and mean duration of diabetes was 12.7 years. Sixty-three percent were male. Seventy-six percent were Caucasian, 9% were Black and 15% were Other. The mean BMI was approximately 29.7 kg/m2.
Insulin aspart was administered by subcutaneous injection immediately prior to meals and regular human insulin was administered by subcutaneous injection 30 minutes before meals. NPH insulin was administered as the basal insulin in either single or divided daily doses. Changes in HbA1c were comparable for the two treatment regimens.
Insulin aspart + NPH (n=90) | Regular Human Insulin + NPH (n=86) |
|
---|---|---|
|
||
Baseline HbA1c (%)* | 8.1 ± 1.2 | 7.8 ± 1.1 |
Change from Baseline HbA1c (%) | -0.3 ± 1.0 | -0.1 ± 0.8 |
Treatment Difference in HbA1c, Mean (95% confidence interval) | -0.1 (-0.4, 0.1) |
MERILOG (insulin aspart-szjj) injection 100 units/mL (U-100) is available as a clear and colorless solution in:
Dosage Unit | NDC # |
---|---|
One 10 mL multiple-dose vial per carton | NDC: 0024-5927-00 |
Five 3 mL single-patient-use SoloStar prefilled pens per carton | NDC: 0024-5928-05 |
The MERILOG SoloStar prefilled pen dials in 1-unit increments.
Needles are not included in MERILOG SoloStar packs. Only use needles that are compatible for use with MERILOG SoloStar which are sold separately, including needles from Becton, Dickinson and company (BD) (such as BD Ultra-Fine®), Ypsomed (such as Clickfine®), and Owen Mumford (such as Unifine® Pentips®).
Dispense in the original sealed carton with the enclosed Instructions for Use.
Store unused MERILOG in a refrigerator between 2°C to 8°C (36°F to 46°F). Do not freeze MERILOG and do not use MERILOG if it has been frozen. Do not expose MERILOG to excessive heat or light.
Do not withdraw MERILOG into a syringe and store for later use.
Always remove and discard the needle after each injection from the MERILOG SoloStar prefilled pen and store without a needle attached.
The storage conditions are summarized in the following table:
MERILOG presentation | Not in-use (unopened) Room Temperature (up to 30°C [86°F]) | Not in-use (unopened) Refrigerated (2°C to 8°C [36°F to 46°F]) | In-use (opened) Room Temperature (up to 30°C [86°F]) |
---|---|---|---|
10 mL multiple-dose vial | 28 days | Until expiration date | 28 days (refrigerated/room temperature) |
3 mL single-patient-use SoloStar prefilled pen | 28 days | Until expiration date | 28 days (Do not refrigerate) |
Advise the patient to read the FDA-approved patient labeling (Patient Information and Instructions for Use).
Never Share a MERILOG SoloStar Prefilled Pen between Patients
Advise patients that they must never share MERILOG SoloStar prefilled pen device with another person even if the needle is changed, because doing so carries a risk for transmission of blood-borne pathogens. Advise patients using MERILOG vials not to share needles or syringes with another person. Sharing poses a risk for transmission of blood-borne pathogens [see Warnings and Precautions (5.1)].
Hyperglycemia or Hypoglycemia
Inform patients that hypoglycemia is the most common adverse reaction with insulin. Instruct patients on self-management procedures including glucose monitoring, proper injection technique, and management of hypoglycemia and hyperglycemia, especially at initiation of MERILOG therapy. Instruct patients on handling of special situations such as intercurrent conditions (illness, stress, or emotional disturbances), an inadequate or skipped insulin dose, inadvertent administration of an increased insulin dose, inadequate food intake, and skipped meals. Instruct patients on the management of hypoglycemia [see Warnings and Precautions (5.3)].
Inform patients that their ability to concentrate and react may be impaired as a result of hypoglycemia. Advise patients who have frequent hypoglycemia or reduced or absent warning signs of hypoglycemia to use caution when driving or operating machinery.
Advise patients that changes in insulin regimen can predispose to hyperglycemia or hypoglycemia and that changes in insulin regimen should be made under close medical supervision [see Warnings and Precautions (5.2)].
Hypoglycemia with Medication Errors
Instruct patients to always check the insulin label before each injection to avoid mix-ups between insulin products [see Warnings and Precautions (5.4)].
Hypersensitivity Reactions
Advise patients that hypersensitivity reactions have occurred with insulin aspart products. Inform patients of the symptoms of hypersensitivity reactions [see Warnings and Precautions (5.5)].
PATIENT INFORMATION MERILOG™ [mer-ih-lawg] (insulin aspart-szjj) injection, for subcutaneous use 100 units/mL (U-100) |
||
---|---|---|
This Patient Information has been approved by the U.S. Food and Drug Administration. | ||
Issued: February 2025 | ||
Do not share your MERILOG SoloStar prefilled pen with other people, even if the needle has been changed. You may give other people a serious infection, or get a serious infection from them. | ||
What is MERILOG?
|
||
Who should not take MERILOG? Do not take MERILOG if you:
|
||
Before taking MERILOG, tell your healthcare provider about all your medical conditions including, if you are:
|
||
How should I take MERILOG?
|
||
What should I avoid while taking MERILOG? While taking MERILOG do not:
|
||
What are the possible side effects of MERILOG? MERILOG can cause serious side effects that can lead to death, including: Low blood sugar (hypoglycemia). Signs and symptoms that may indicate low blood sugar include: |
||
|
|
|
Your insulin dose may need to change because of: | ||
|
|
|
Other common side effects of MERILOG may include:
|
||
General information about the safe and effective use of MERILOG.
Medicines are sometimes prescribed for purposes other than those listed in a Patient Information leaflet. You can ask your pharmacist or healthcare provider for information about MERILOG that is written for health professionals. Do not use MERILOG for a condition for which it was not prescribed. Do not give MERILOG to other people, even if they have the same symptoms that you have. It may harm them. |
||
What are the ingredients in MERILOG?
Active Ingredient: insulin aspart-szjj Inactive Ingredients: metacresol, phenol, polysorbate 20, sodium chloride, zinc chloride and Water for Injection, USP. Hydrochloric acid and/or sodium hydroxide may be added to adjust pH. Manufactured by: sanofi-aventis U.S. LLC, Bridgewater, NJ 08807, A SANOFI COMPANY. U.S. License No. 1752 For more information, go to www.sanofi.com or call 1-800-633-1610. ©2025 Sanofi. All rights reserved. All trademarks mentioned in this document are the property of the Sanofi group. |
This Instructions for Use contains information on how to inject MERILOG.
Read this Instructions for Use before you start taking MERILOG and each time you get a new MERILOG vial. There may be new information. This information does not take the place of talking to your healthcare provider about your medical condition or your treatment.
Do not share your MERILOG syringes with other people, even if the needle has been changed. You may give other people a serious infection, or get a serious infection from them.
Supplies needed to give your injection
Preparing your MERILOG dose
Need help?
If you have any questions about your vial or about diabetes, ask your healthcare provider, or call sanofi-aventis at 1-800-633-1610.
Step 1:
If you are using a new vial, remove the protective cap. Do not remove the stopper (see Figure A).
Step 2:
Wipe the top of the vial with an alcohol swab. You do not have to shake the vial of MERILOG before use (see Figure B).
Step 3:
Draw air into the syringe equal to your insulin dose (see Figure C). Put the needle through the rubber top of the vial and push the plunger to inject the air into the vial (see Figure D).
Step 4:
Leave the syringe in the vial and turn both upside down. Hold the syringe and vial firmly in one hand. Make sure the tip of the needle is in the insulin. With your free hand, pull the plunger to withdraw the correct dose into the syringe (see Figure E).
Step 5:
Before you take the needle out of the vial, check the syringe for air bubbles. If bubbles are in the syringe, hold the syringe straight up and tap the side of the syringe until the bubbles float to the top. Push the bubbles out with the plunger and draw insulin back in until you have the correct dose (see Figure F).
Step 6:
Remove the needle from the vial. Do not let the needle touch anything. You are now ready to inject.
Giving your MERILOG injection with a syringe
Step 7:
Step 8:
Step 9:
Disposing of used needles and syringes
How should I store MERILOG?
Unopened (not in-use) MERILOG vials
After MERILOG vials have been opened (in-use)
Manufactured by:
sanofi-aventis U.S. LLC
Bridgewater, NJ 08807
A SANOFI COMPANY
U.S. License No. 1752
©2025 Sanofi. All rights reserved.
All trademarks mentioned in this document are the property of the Sanofi group.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Approved: February 2025
This Instructions for Use contains information on how to inject MERILOG.
Read this Instructions for Use before you start taking MERILOG and each time you get a new MERILOG SoloStar prefilled pen. There may be new information. This information does not take the place of talking to your healthcare provider about your medical condition or your treatment.
Do not share your MERILOG SoloStar prefilled pen with other people, even if the needle has been changed. You may give other people a serious infection, or get a serious infection from them.
People who are blind or have vision problems should not use MERILOG SoloStar prefilled pen without help from a person trained to use MERILOG SoloStar prefilled pen.
MERILOG SoloStar is a disposable prefilled pen used to inject MERILOG. Each MERILOG SoloStar has 300 units of insulin which can be used for multiple injections. You can select doses from 1 to 80 units in steps of 1 unit. The pen plunger moves with each dose. The plunger will only move to the end of the cartridge when 300 units of insulin have been given.
Important information
Learn to inject
Need help?
If you have any questions about your pen or about diabetes, ask your healthcare provider, or call sanofi-aventis at 1-800-633-1610.
Extra items you will need:
Get to know your pen
Step 1: Check your pen
Take a new pen out of the refrigerator at least 1 hour before you inject. Cold insulin is more painful to inject.
1A Check the name and expiration date on the label of your pen.
1B Pull off the pen cap (see Figure D).
1C Check that the insulin is clear and colorless (see Figure E).
1D Wipe the rubber seal with an alcohol swab (see Figure F).
If you have other injector pens:
2A Take a new needle and peel off the protective seal (see Figure G).
2B Keep the needle straight and screw it onto the pen until fixed. Do not over-tighten (see Figure H).
2C Pull off the outer needle cap. Keep this for later (see Figure I).
2D Pull off the inner needle cap and throw away (see Figure J).
Handling needles:
Always do a safety test before each injection to:
You must perform safety tests before you use the pen until you see insulin coming out of the needle tip. If you see insulin coming out of the needle tip, the pen is ready to use. If you do not see insulin coming out before taking your dose, you could get an underdose or no insulin at all. This could cause high blood sugar.
3A Select 2 units by turning the dose selector until the dose pointer is at the 2 mark (see Figure K).
3B Press the injection button all the way in (see Figure L).
If no insulin appears:
If you see air bubbles:
Step 4: Select the dose
Do not select a dose or press the injection button without a needle attached. This may damage your pen.
4A Make sure a needle is attached and the dose is set to "0" (see Figure M).
4B Turn the dose selector until the dose pointer lines up with your dose (see Figure N).
How to read the dose window
Even numbers are shown in line with dose pointer (see Figure O).
Odd numbers are shown as a line between even numbers (see Figure P).
Units of insulin in your pen:
Step 5: Inject your dose
If you find it hard to press the injection button in, do not force it as this may break your pen. See the section after Step 5E below for help.
5A Choose a place to inject as shown in the picture labeled "Places to inject" (see Figure A). Wipe the skin with an alcohol swab to clean the injection site. Let the injection site dry before you inject your dose.
5B Push the needle into your skin as shown by your healthcare provider (see Figure Q).
5C Place your thumb on the injection button. Then press all the way in and hold (see Figure R).
5D Keep the injection button held in and when you see "0" in the dose window, slowly count to 10 (see Figure S).
5E After holding and slowly counting to 10, release the injection button. Then remove the needle from your skin.
If you find it hard to press the button in:
6A Grip the widest part of the outer needle cap. Keep the needle straight and guide it into the outer needle cap. Then push firmly on (see Figure T).
6B Grip and squeeze the widest part of the outer needle cap. Turn your pen several times with your other hand to remove the needle (see Figure U).
6C Throw away the used needle in a puncture-resistant container (see Figure V) (see "Throwing your pen away" at the end of this Instructions for Use).
6D Put your pen cap back on (see Figure W).
How to store your pen
Before first use
After first use
How to care for your pen
Handle your pen with care
Protect your pen from dust and dirt
Manufactured by:
sanofi-aventis U.S. LLC
Bridgewater, NJ 08807
A SANOFI COMPANY
U.S. License No. 1752
©2025 Sanofi. All rights reserved.
All trademarks mentioned in this document are the property of the Sanofi group with the exception of BD Ultra-Fine, Clickfine, Unifine, and Pentips.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Approved: February 2025
NDC: 0024-5927-00
Rx only
Merilog™
(insulin aspart-szjj) injection
100 units/mL (U-100)
For subcutaneous injection only
Dosage: See Prescribing Information
10 mL multiple-dose vial
Mfd by: sanofi-aventis U.S. LLC
U.S. Lic. No. 1752
<MAT>930716
NDC: 0024-5927-00
Rx only
Merilog™
(insulin aspart-szjj) injection
100 units/mL (U-100)
For subcutaneous injection only
Use only with a U-100 syringe
One 10 mL multiple-dose vial
sanofi
NDC: 0024-5928-00
3 mL Prefilled Pen
Rx only
Merilog™ SoloStar®
(insulin aspart-szjj) injection
For Single Patient Use Only
100 units/mL (U-100)
For subcutaneous injection only
Dosage: See Prescribing Information
Mfd by: sanofi-aventis U.S. LLC. U.S. Lic. No. 1752
Rx only
NDC: 0024-5928-05
Merilog™ SoloStar®
(insulin aspart-szjj) injection
For Single Patient Use Only
100 units/mL (U-100)
For subcutaneous injection only
Do not mix with other insulins
Needles not included
Dispense in this sealed carton
Five 3 mL Prefilled Pens
sanofi
MERILOG
insulin aspart-szjj injection, solution |
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
MERILOG
insulin aspart-szjj injection, solution |
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
Labeler - Sanofi-Aventis U.S. LLC (824676584) |
Registrant - Sanofi-Aventis Deutschland GmbH (313218430) |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Sanofi-Aventis Deutschland GmbH | 313218430 | MANUFACTURE(0024-5927, 0024-5928) , API MANUFACTURE(0024-5927, 0024-5928) , PACK(0024-5927, 0024-5928) , LABEL(0024-5927, 0024-5928) |
Mark Image Registration | Serial | Company Trademark Application Date |
---|---|
![]() MERILOG 97621322 not registered Live/Pending |
Sanofi 2022-10-06 |