ReNew XR Handpiece with Reference Length Markings

Primary DI
00081109901429
Brand
ReNew XR Handpiece with Reference Length Markings
Company
MICROLINE SURGICAL, INC.
Model
3944M
Published
2024-05-03
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K234147000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K234147000ReNew XR Handpiece, 25cm, with Reference Markings (3943M); ReNew XR Handpiece, 34cm, with Reference Markings (3941M); ReNew XR Handpiece, 42cm, with Reference Markings (3942M); ReNew XR Handpiece, Ratcheted, 25cm, with Reference Markings (3946M); ReNew XR Handpiece, Ratcheted, 34cm, with Reference Markings (3944M); ReNew XR Handpiece, Ratcheted, 42cm, with Reference Markings (3945M)Microline Surgical, Inc.2024-04-23GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00081109901429PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00081109901429000811099014290811099014290081109901429

GMDN Terms#

Term, Definition table
TermDefinition
Electrosurgical handpiece, reusableA hand-held component of an electrosurgical system intended to provide an electrical connection between the system generator and a detachable electrode at its distal end, enabling the surgeon controlled manipulation of the electrode during surgery; the electrode is not included. The device is typically in the form of a pen with permanently attached cables for connection to the generator; it is not intended for use during inert gas-enhanced electrosurgery. This is a reusable device.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
184080570
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
false
Serial number
true
Manufacturing date on label
true
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00811099014386REVEEL - Endoscopic Retractor - PercutaneousRV0930012025-09-22
00811099014416REVEEL - Endoscopic Retractor - TrocarRT0830012025-09-22
00811099014393REVEEL - Endoscopic Retractor - PercutaneousRV0930012025-09-22
00811099014423REVEEL - Endoscopic Retractor - TrocarRT0830012025-09-22
00811099014348ReNew Disposable Tenaculum Tip (5mm)33922025-09-09
00811099014362ReNew Disposable Tenaculum Tip (10mm)34222025-09-09
00811099014331ReNew Disposable Tenaculum Tip (5mm)33922025-09-09
00811099014355ReNew Disposable Tenaculum Tip (10mm)34222025-09-09
00811099014294ReNew XR Handpiece with Reference Length Markings3944M2024-05-03
00811099014256ReNew XR Handpiece with Reference Length Markings3943M2024-05-03
00811099014263ReNew XR Handpiece with Reference Length Markings3941M2024-05-03
00811099014270ReNew XR Handpiece with Reference Length Markings3942M2024-05-03
00811099014287ReNew XR Handpiece with Reference Length Markings3946M2024-05-03
00811099014300ReNew XR Handpiece with Reference Length Markings3945M2024-05-03
00811099013822ReNew XR353035302023-06-07
00811099013839ReNew XR353135312023-06-07
00811099013846ReNew XR35322023-06-07
00811099013853ReNew XR35332023-06-07
00811099011408Microline102-137D102-137D2017-11-13
00811099011415Microline102-138D102-138D2017-11-13

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00197998302718Solventum™Solventum US LLCGEI2026-09-25
00724995269586Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269951Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269968Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00190776432300MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432317MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432324MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432430MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432447MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432454MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776431457MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432041MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432195MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432201MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776431181MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431198MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431204MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431211MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431228MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431235MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431242MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431259MillenniumAvalign Technologies, Inc.GEI2026-09-21
10840113236852BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236890BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236937BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237040BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237064BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237101BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237118BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237132BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21