Tecnimed - BV Medical

Primary DI
00182097000177
Brand
Tecnimed - BV Medical
Company
TECNIMED SRL
Model
VisioFocus 06400
Catalog number
06400
Device description
Infrared non contact thermometer intended for the intermittent measurement of human body temperature in people of all ages
Published
2017-03-10
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
OTC
true

Product Codes#

Code, Name table
CodeName
FLLThermometer, Electronic, Clinical

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FLLContinuous Measurement ThermometerGeneral Hospital2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K122412000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K122412000VISIOFOCUSTecnimed S.R.L.2013-03-13FLL

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00182097000184PackageGS190In Commercial Distribution
00182097000467PackageGS145In Commercial Distribution
00182097000610PackageGS150In Commercial Distribution
00182097000177PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00182097000184001820970001841820970001840182097000184
00182097000467001820970004671820970004670182097000467
00182097000610001820970006101820970006100182097000610
00182097000177001820970001771820970001770182097000177

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure700 millibar1060 millibar
Handling Environment Humidity15 Percent (%) Relative Humidity93 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius45 Degrees Celsius
Storage Environment Temperature-18 Degrees Celsius70 Degrees Celsius

Regulatory Flags#

DUNS number
445878788
Device count
1
Lot or batch
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00182097000238Tecnimed - Handi-Craft CompanyVisioFocus SMART064702017-06-27
00182097000689Tecnimed - HammacherVisioFocus064002021-01-20
00182097000696Tecnimed - HammacherVisioFocus064002021-01-20
00182097000078Tecnimed - BV MedicalThermofocus 08000800H52016-09-12
00182097000559TECNIMED - Medline Industries, IncVisioFocus PRO 06480064802020-08-11
00182097000511Tecnimed VisioFocus PRO 06480064802020-06-04
00182097000474Tecnimed - BV MedicalVisioFocus PRO 06480064802020-04-13
00182097000498TECNIMED - Hopkins Medical ProductsVisioFocus PRO 06480064802020-04-13
00182097000429Tecnimed - 3J MEDICAL SUPPLIES IncVisioFocus MINI067002019-09-10
00182097000436Tecnimed - 3J MEDICAL SUPPLIES IncVisioFocus064002019-09-10
00182097000443Tecnimed - 3J MEDICAL SUPPLIES IncVisioFocus PRO064802019-09-10
00182097000054Tecnimed - BV MedicalThermofocus 07000700A22016-09-12
00182097000061Tecnimed - BV MedicalThermofocus 0150001500A32016-09-12
00182097000139Hopkins Medical ProductsTouch-Free ThermometerThermofocus 01500A32016-09-20
00182097000153TECNIMED - Hopkins Medical ProductsVisioFocus 06400064002017-02-17
00182097000191Tecnimed - Constant Care TechnologyThermofocus 08002017-03-30
00182097000351TecnimedVisioFocus MINI067002018-07-30
00182097000368TECNIMEDDisc-o-Click2018-05-15
00182097000023TecnibrandsClick2017-08-02
00182097000382TECNIMEDDisc-o-Click2018-05-15

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00841709121708MidmarkMIDMARK CORPORATIONFLL2026-11-09
00841709121715MidmarkMIDMARK CORPORATIONFLL2026-11-09
00841709121722MidmarkMIDMARK CORPORATIONFLL2026-11-09
00841709121739MidmarkMIDMARK CORPORATIONFLL2026-11-09
09120095900410SteadyTempSteadySense GmbHFLL2026-11-09
09120095900427SteadyTempSteadySense GmbHFLL2026-11-09
09120095900458SteadyTempSteadySense GmbHFLL2026-11-09
06944413830745TEMP cableEdan Instruments, Inc.FLL2026-11-06
06944413831636TEMP probeEdan Instruments, Inc.FLL2026-11-06
06944413831957TEMP probeEdan Instruments, Inc.FLL2026-11-06
06944413831964TEMP probeEdan Instruments, Inc.FLL2026-11-06
06944413831971TEMP probeEdan Instruments, Inc.FLL2026-11-06
06970331860830Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860847Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860854Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860861Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860878Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860885Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860892Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331860908Infrared thermometerShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331862704TIXMORShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-06
06970331862711TIXMORShenzhen Ruiankang Technology Co. Ltd.FLL2026-11-05
00681131280228EquateWAL-MART STORES, INC.FLL2026-11-03
09120095900816SteadyTempSteadySense GmbHFLL2026-11-03
09120095900823SteadyTempSteadySense GmbHFLL2026-11-03
00841709121746MidmarkMIDMARK CORPORATIONFLL2026-10-30
00841709121753MidmarkMIDMARK CORPORATIONFLL2026-10-30
00841709121760MidmarkMIDMARK CORPORATIONFLL2026-10-30
00841709121777MidmarkMIDMARK CORPORATIONFLL2026-10-30
00860016681507UNIVERHEALTHHangzhou Universal Electronic Co.,Ltd.FLL2026-10-28