IdentiTi

Primary DI
00190376180878
Brand
IdentiTi
Company
ALPHATEC SPINE, INC.
Model
126-09161410-S
Device description
IdentiTi Cervical Porous Ti Spacer, 9 x 16 x 14 mm, 10°
Published
2019-11-02
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
ODPIntervertebral fusion device with bone graft, cervical

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ODPIntervertebral Fusion Device With Bone Graft, CervicalOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K183705000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K183705000IdentiTi Porous Ti Interbody SystemAlphatec Spine, Inc.2019-03-01MAX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00190376180878PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00190376180878001903761808781903761808780190376180878

GMDN Terms#

Term, Definition table
TermDefinition
Metallic spinal interbody fusion cageA device intended to be implanted into the space of an intervertebral disc that has been partially or totally removed during surgery in order to allow bone fusion between two contiguous vertebral bodies, typically in the treatment of degenerative disc disease (DDD). It is in the form of a hollow, porous, threaded and/or fenestrated cylindrical or geometrical device made of metal [e.g., titanium (Ti)] that provides mechanical stability and sufficient space for therapeutic spinal bone fusion to occur; bone graft is typically used to help with osseointegration. Fixation screws and devices associated with implantation may be included with the device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Angle10degree
Depth14Millimeter
Height9Millimeter
Width16Millimeter

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(760)431-9286Regulatory@alphatecspine.com

Regulatory Flags#

DUNS number
602465783
Device count
1
DM exempt
true
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00840967110981AlphaGRAFT1002-1002015-09-24
00840967110998AlphaGRAFT1001-0102015-09-24
00840967111001AlphaGRAFT1001-1002015-09-24
00844856026711AlphaGRAFT1001-0502015-09-24
00844856026728AlphaGRAFT1002-0252015-09-24
00844856026735AlphaGRAFT1002-0502015-09-24
00844856032231Osseofix +213902016-10-28
00190376649474CONTOUR3DAIX761032026-09-25
00190376652313CONTOUR3DAIX761012026-09-25
00190376652320CONTOUR3DAIX761022026-09-25
00190376652337CONTOUR3DAIX761042026-09-25
00190376668307CONTOUR3DAIX760002026-09-25
00190376733470CONTOUR3DC3DRODA2026-09-25
00190376778372InvictusVMRIN2026-08-19
00190376778396InvictusVMTIN2026-08-19
00190376768847Invictus171442026-08-17
00190376544397Invictus17920-012026-07-30
00190376544403Invictus17920-022026-07-30
00190376544410Invictus17920-032026-07-30
00190376544427Invictus17920-042026-07-30

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
B084AC1141605070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141606070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141607070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141608070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141609070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141610070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141611070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1141612070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161805000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161805040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161805070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161806000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161806040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161806070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161807000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161807040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161807070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161808000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161808040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161808070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161809000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161809040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161809070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161810000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161810040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161810070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161811000Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161811040Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161811070Anterior Cervical IBFDKEOSODP2024-02-09
B084AC1161812000Anterior Cervical IBFDKEOSODP2024-02-09