Shockwave IVL System with the Shockwave L6 Peripheral IVL Catheter

Primary DI
00195451000386
Brand
Shockwave IVL System with the Shockwave L6 Peripheral IVL Catheter
Company
Shockwave Medical, Inc.
Model
L6IVL080030
Catalog number
L6IVL080030
Device description
The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable.
Published
2022-10-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
JAASystem, X-Ray, Fluoroscopic, Image-Intensified
OEZCardiovascular Procedure Kit
PPNPercutaneous Catheter, Ultrasound

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JAASystem, X-Ray, Fluoroscopic, Image-IntensifiedRadiology2
OEZCardiovascular Procedure KitCardiovascular2
PPNPercutaneous Catheter, UltrasoundCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K221852000
K240954000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K221852000Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave L6 Peripheral IVL CatheterShockwave Medical, Inc.2022-08-16PPN
K240954000Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave L6 Peripheral IVL CatheterShockwave Medical, Inc.2024-05-07PPN

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00195451000386PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00195451000386001954510003861954510003860195451000386

GMDN Terms#

Term, Definition table
TermDefinition
Ultrasonic lithotripsy system transducer, single-useA catheter-enclosed device used as a component of an ultrasonic lithotripsy system to transform electrical energy into ultrasonic energy to deliver localized lithotripsy treatments (the breaking up of a stone or calculus). It is introduced into the body through vascular access, surgically, or endoscopically. This ultrasound transducer is composed of either a single transducer element or an array of transducer elements [i.e., piezoelectric or active element(s), or crystal(s) and associated damping, backing, and matching layer materials]. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Balloon Diameter8Millimeter
Balloon Length30Millimeter
Balloon Nominal (Inflation) Pr2Atmosphere
Balloon Nominal (Inflation) Pr3Atmosphere
Balloon Nominal (Inflation) Pr4Atmosphere
Balloon Proximal Outer Diamete0.091Inch
Balloon Rated Burst Pressure6Atmosphere
Catheter Working Length110Centimeter
Guidewire Diameter0.018Inch
Introducer Sheath Compatibilit7French

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Keep dry and away from heat

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
1-877-775-4846CS@shockwavemedical.com

Regulatory Flags#

DUNS number
055514478
Device count
1
Kit
true
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00195451000003Shockwave IVL System with the Shockwave C2+ Coronary IVL CatheterC2PIVL2512C2PIVL25122023-08-16
00195451000010Shockwave IVL System with the Shockwave C2+ Coronary IVL CatheterC2PIVL3012C2PIVL30122023-08-16
00195451000027Shockwave IVL System with the Shockwave C2+ Coronary IVL CatheterC2PIVL3512C2PIVL35122023-08-16
00195451000034Shockwave IVL System with the Shockwave C2+ Coronary IVL CatheterC2PIVL4012C2PIVL40122023-08-16
00195451001123Shockwave IVL System with the Shockwave C2 Aero Fly Coronary IVL CatheterC2AFIVL2512C2AFIVL25122026-05-14
00195451001130Shockwave IVL System with the Shockwave C2 Aero Fly Coronary IVL CatheterC2AFIVL3012C2AFIVL30122026-05-14
00195451001147Shockwave IVL System with the Shockwave C2 Aero Fly Coronary IVL CatheterC2AFIVL3512C2AFIVL35122026-05-14
00195451001154Shockwave IVL System with the Shockwave C2 Aero Fly Coronary IVL CatheterC2AFIVL4012C2AFIVL40122026-05-14
00195451000799Shockwave IVL System with the Shockwave Javelin Peripheral IVL CatheterJVNPIVLFJVNPIVLF2024-10-09
00195451000591Shockwave IVL System with the Shockwave C2 Aero Coronary IVL CatheterC2AIVL2512C2AIVL25122025-07-10
00195451000607Shockwave IVL System with the Shockwave C2 Aero Coronary IVL CatheterC2AIVL3012C2AIVL30122025-07-10
00195451000614Shockwave IVL System with the Shockwave C2 Aero Coronary IVL CatheterC2AIVL3512C2AIVL35122025-07-10
00195451000621Shockwave IVL System with the Shockwave C2 Aero Coronary IVL CatheterC2AIVL4012C2AIVL40122025-07-10
00195451000539Shockwave IVL System with the Shockwave E8 Peripheral IVL CatheterE8IVL025080E8IVL0250802024-04-17
00195451000546Shockwave IVL System with the Shockwave E8 Peripheral IVL CatheterE8IVL030080E8IVL0300802024-04-17
00195451000553Shockwave IVL System with the Shockwave E8 Peripheral IVL CatheterE8IVL035080E8IVL0350802024-04-17
00195451000560Shockwave IVL System with the Shockwave E8 Peripheral IVL CatheterE8IVL040080E8IVL0400802024-04-17
00195451000577Shockwave IVL System with the Shockwave E8 Peripheral IVL CatheterE8IVL050080E8IVL0500802024-04-17
00195451000584Shockwave IVL System with the Shockwave E8 Peripheral IVL CatheterE8IVL060080E8IVL0600802024-04-17
00195451000393Shockwave IVL System with the Shockwave L6 Peripheral IVL CatheterL6IVL090030L6IVL0900302022-10-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00884450426630Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-03
00884450437438Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-03
00884450486887Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-03
10198956320123CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956328938CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956444027CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956468023CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956477230CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956486843CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956489073CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956490468CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956490529CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956492721CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956496613CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956498662CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
10198956500440CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-03
00884450424087Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-02
00884450435403Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-02
00884450474549Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-02
00884450474556Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-02
00884450474563Merit Medical®Merit Medical Systems, Inc.OEZ2026-06-02
10198956311282CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956340145CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956392281CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956420816CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956428089CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956429345CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956436428CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956457140CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01
10198956458796CARDINAL HEALTHCardinal Health 200, LLCOEZ2026-06-01