Primary Device ID | 00607567701298 |
NIH Device Record Key | 58ba42da-7877-42f3-b3d5-ae4291098e11 |
Commercial Distribution Status | In Commercial Distribution |
Brand Name | Vasoview Hemopro 3 Power Adapter |
Version Model Number | VH-6020 |
Catalog Number | VH-6020 |
Company DUNS | 022348156 |
Company Name | MAQUET CARDIOVASCULAR LLC |
Device Count | 1 |
DM Exempt | false |
Pre-market Exempt | true |
MRI Safety Status | Labeling does not contain MRI Safety Information |
Human Cell/Tissue Product | false |
Device Kit | false |
Device Combination Product | false |
Single Use | false |
Lot Batch | true |
Serial Number | false |
Manufacturing Date | true |
Expiration Date | false |
Donation Id Number | false |
Contains Natural Rubber Latex | false |
Labeled No Natural Rubber Latex | false |
RX Perscription | true |
OTC Over-The-Counter | false |
00607567701274 - Vasoview Hemopro 3 Endoscopic Vessel Harvesting System | 2024-05-29 The Vasoview Hemopro 3 Endoscopic Vessel Harvesting System is designed for use in conjunction with the 7 mm Endoscope. The Harve |
00607567701298 - Vasoview Hemopro 3 Power Adapter | 2024-05-29The Vasoview Hemopro 3 Endoscopic Vessel Harvesting System is designed for use in conjunction with the 7 mm Endoscope. The Harvesting Cannula has four lumens which house the Endoscope, C-Ring, distal lens washer tube and Vasoview Hemopro 3 Harvesting Tool for cutting and cauterization of vessel branches. The C-Ring with the built-in distal lens washer is independently controlled by a C-Ring Slider on the handle of the Harvesting Cannula. The C-Ring cradles the vessel and delivers the saline that washes the distal tip of the Endoscope.
The Harvesting Tool can be inserted, removed, rotated, extended, and retracted from the main Harvesting Cannula through the Tool Adapter Port.
The Harvesting Tool is powered by direct current (DC) only; it does not utilize RF (radio frequency) energy. The Harvesting Tool cuts and cauterizes through a process of heat and pressure. The Harvesting Tool has two curved Jaws. One of the Jaws contains the heating elements for branch cutting and cauterization and spot cautery. There are three heating elements: two cauterization elements and a cutting element between them. Both Jaws have insulation protecting the adjacent tissue. The concave side of the Jaws has a larger buffer of insulation and therefore should be positioned toward sensitive tissue during Jaw activation. An area near the tip of the convex side of the Jaw can be used for spot cautery to cauterize tissue contacted by that area of the Jaw.
The Activation Toggle is used to control the Jaws and to activate the heating elements. Positioning of the device, cutting, and cauterization are performed under endoscopic visualization. This device is intended for specific use with the Vasoview Hemopro Power Supply and Vasoview Hemopro 3 Power Adapter. |
00607567701298 - Vasoview Hemopro 3 Power Adapter | 2024-05-29 The Vasoview Hemopro 3 Endoscopic Vessel Harvesting System is designed for use in conjunction with the 7 mm Endoscope. The Harve |
00607567701335 - Vasoview Hemopro 3 Endoscopic Vessel Harvesting System with Vasoshield | 2024-05-29 The Vasoview Hemopro 3 Endoscopic Vessel Harvesting System is designed for use in conjunction with the 7 mm Endoscope. The Harve |
00607567500006 - Acrobat-i Positioner | 2020-05-05 Acrobat-i Positioner |
00607567900004 - Acrobat SUV Stabilizer | 2020-05-05 Acrobat SUV Stabilizer |
00607567100008 - Acrobat-I Stabilizer | 2020-01-08 Acrobat-I Stabilizer |
00607567700745 - Axius Blower Mister | 2019-04-23 Axius Blower Mister |
00607567700462 - Vasoshield | 2019-02-21 Vasoshield Pressure Controlling Syringe |