Delasco Electricator

Primary DI
00609960000251
Brand
Delasco Electricator
Company
DERMATOLOGIC LAB AND SUPPLY, INC.
Model
26000
Catalog number
26000
Device description
DESCRIPTIONThe Delasco Electricator is a non-sterile, reusable, electrosurgical generator. The Electricator is designed to generate high frequencies (radio frequency “RF”) of high voltage and low amperage current. The unit incorporates a ground-referenced monopolar and bipolar output which is used primarily in physician’s offices and treatment rooms to perform electrosurgical desiccation, fulguration, and coagulation procedures (described below). Patients with dermatological lesions such as cysts, polyps, and carbuncles can be treated with the Electricator with or without the use of anesthesia (depending on the site of the procedure and the patient tolerance level).INTENDED USEThe Delasco Electricator is intended to be utilized for destroying skin lesions and to coagulate small bleeders by applying high frequency current. The unit is used primarily in the Physician’s office and in particular, those of Dermatologists and Plastic Surgeons.
Published
2016-05-19
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00609960000251PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00609960000251006099600002516099600002510609960000251

GMDN Terms#

Term, Definition table
TermDefinition
Electrosurgical system generatorA mains electricity-powered (AC-powered) component of a electrosurgical system intended to generate radio-frequency (RF) electrical current for subsequent cutting and coagulation of soft tissues during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system generator). It includes controls, may include an integrated surgical plume (smoke) suction unit, and is intended to be connected via a cable to an electrosurgical handpiece and electrode (neither of these are included); it is not intended for argon-enhanced electrosurgery.

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
021628771
Device count
1
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00609960000190Delasco 734 Handpiece734/H2016-05-13
00609960000268ELECTRICATOR HANDPIECE26300263002016-05-19
10609960000012Delasco Biopsy SutureBDL-40B2015-11-02
10609960000029Delasco Biopsy SutureBDL-50B2015-11-02
10609960000036Delasco Biopsy SutureBDL-60B2015-11-02
10609960000043Delasco Biopsy SutureMS-40B2015-11-02
10609960000050Delasco Biopsy SutureMS-50B2015-11-02
10609960000067Delasco Biopsy SutureMS-60B2015-11-02
00609960001326Smoke Evacuator FilterEV-I/REV-I/R2020-09-30
00609960001302SaftEvacEV-IEV-I2020-09-16
00609960001296Delasco SaftEvac FilterEV/XEV/X2020-08-04
00609960000282Delasco Electricator Reusable Patient Plate26900269002016-06-15
00609960001289Segal ElectrodeSE/G1SE/G2019-12-31
10609960000135ElectroTipsET-1012016-05-13
10609960000142ElectroTipsET-1022016-05-13
10609960000159ElectroTipsET-1032016-05-13
10609960000166ElectroTipsET-1042016-05-13
10609960000173Electrolite262002016-05-13
10609960000180Electrolite26200S2016-05-13
10609960001248Electrolite262502018-07-10

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07613327666878N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666885N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666892N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666908N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666915N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666922N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
00190776421755MillenniumAvalign Technologies, Inc.GEI2026-06-24
00813527028590E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028613E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028637E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028651E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028675E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028699E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028712E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028736E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028750E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028774E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028798E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028811E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028835E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028859E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028873E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028897E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028910E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527029153E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
B112S03086NSU200STINGRAY SURGICAL PRODUCTSSTINGRAY SURGICAL PRODUCTS L.L.C.GEI2026-06-10
00198506091292ELMED INCORPORATEDELMED INCORPORATEDGEI2026-06-09
00198506091308ELMED INCORPORATEDELMED INCORPORATEDGEI2026-06-09
00198506091360ELMED INCORPORATEDELMED INCORPORATEDGEI2026-06-09
00198506091377ELMED INCORPORATEDELMED INCORPORATEDGEI2026-06-09