ADVIA Centaur® COR +E

Primary DI
00630414524610
Brand
ADVIA Centaur® COR +E
Company
Siemens Healthcare Diagnostics Inc.
Model
10321026
Catalog number
4610138
Device description
Cortisol - CENTAUR - RGT - 250 tests
Published
2016-09-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
JFTFLUOROMETRIC, CORTISOL

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JFTFluorometric, CortisolClinical Chemistry2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K962559000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K962559000ACS CORTISOL IMMUNOASSAYCiba Corning Diagnostics Corp.1996-11-05JFT

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00630414524610PrimaryGS10
00630414011158Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00630414524610006304145246106304145246100630414524610
00630414011158006304140111586304140111580630414011158

GMDN Terms#

Term, Definition table
TermDefinition
Total cortisol IVD, kit, chemiluminescent immunoassayA collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of total cortisol in a clinical specimen, using a chemiluminescent immunoassay method.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Temperature2 Degrees Celsius8 Degrees Celsius
Special Storage Condition, Specify00Store Upright, Protect from Light, Do not freeze, Resuspend
Storage Environment Temperature2 Degrees Celsius8 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(877)229-3711XX@XX.XX
+1(877)229-3711CONTACT@SIEMENS-HEALTHINEERS.COM

Regulatory Flags#

DUNS number
064608573
Device count
5
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00630414596167Atellica CH ASO_211097634110976342020-09-24
00630414596259Atellica CH PreAlb11097617110976172020-09-24
00630414596440Atellica CH GGT11097597110975972020-09-24
00630414596174Atellica CH hsCRP11097633110976332017-12-21
00630414596198Atellica CH CRP_211097631110976312017-12-27
00630414597508Atellica CH hsCRP Calibrator11099412110994122017-12-22
00630414597515Atellica CH CRP_2 Calibrator11099430110994302017-12-22
00630414611075Atellica CH Crea311537215115372152026-05-08
00630414611297Atellica CH RCRP Cal11537245115372452024-02-02
00842768037726Dimension EXL LOCI Troponin I High Sensitive10471068104710682019-10-16
00630414596099Atellica CH Thc11097503110975032017-12-27
00630414510156ADVIA® Chemistry PAMY Pancreatic Amylase Reagents1031517814108202016-09-24
00630414595641Atellica CH PAmy11097622110976222017-12-21
00630414608273ADVIA Centaur Tumor Marker Quality Control (TM QC)11538186115381862026-05-29
00630414622859Atellica IM Tumor Marker Quality Control (TM QC)11538187115381872026-05-29
00630414517681ADVIA® Chemistry ASO_2 Anti-Streptolysin-O_2 Reagents1031820830554832020-09-24
00842768016912Dimension® PBNP Calibrator10445008RC423A2016-09-24
00630414498942ADVIA® Chemistry ACET Acetaminophen Reagents1032738179891382016-09-24
00630414568768ADVIA® Chemistry BENZ_2 Benzodiazepine_2 Reagents10378760103787602016-09-24
00630414653259Atellica CH Crea311537567115375672026-05-08

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07613336180778Elecsys Cortisol IIIRoche Diagnostics GmbHJFT2025-07-24
00630414598666Atellica IM Cor MCMSiemens Healthcare Diagnostics Inc.JFT2020-09-24
00630414293608Atellica IM CorSiemens Healthcare Diagnostics Inc.JFT2020-05-31
00630414294155Atellica IM CorSiemens Healthcare Diagnostics Inc.JFT2020-05-31
00380740130053AlinityAbbott Ireland DiagnosticsJFT2018-08-10
00380740130060AlinityAbbott Ireland DiagnosticsJFT2018-08-10
04015630939985Elecsys Cortisol IIRoche Diagnostics GmbHJFT2018-06-06
00630414598642Atellica IM CorSiemens Healthcare Diagnostics Inc.JFT2018-02-06
00630414598659Atellica IM CorSiemens Healthcare Diagnostics Inc.JFT2018-02-06
00630414598673Atellica Cort Urine Recon BufferSiemens Healthcare Diagnostics Inc.JFT2018-02-06
14560189210735ST AIA-PACK CORTTOSOH CORPORATIONJFT2016-09-24
04560189211698AIA-PACK CORT Calibrator SetTOSOH CORPORATIONJFT2016-09-24
04560189211704AIA-PACK CORT Sample Diluting SolutionTOSOH CORPORATIONJFT2016-09-24
00630414121819ADVIA Centaur Cortisol Urine Reconstitution BufferSiemens Healthcare Diagnostics Inc.JFT2016-09-24
00630414524740ADVIA Centaur® COR MCMSiemens Healthcare Diagnostics Inc.JFT2016-09-24
00630414602943ADVIA Centaur® CORSiemens Healthcare Diagnostics Inc.JFT2016-09-24
00630414602950ADVIA Centaur® COR +ESiemens Healthcare Diagnostics Inc.JFT2016-09-24
04015630940677Elecsys Cortisol IIRoche Diagnostics GmbHJFT2016-09-20
03573026551469VIDAS® Serum FreeBIOMERIEUX SAJFT2016-08-31
03573026097295VIDAS® Serum FreeBIOMERIEUX SAJFT2016-08-31
00380740016258ARCHITECTAbbott Ireland DiagnosticsJFT2016-06-06
00380740016265ARCHITECTAbbott Ireland DiagnosticsJFT2016-06-06
00380740016272ARCHITECTAbbott Ireland DiagnosticsJFT2016-06-06