AdviewII™

Primary DI
00634782094911
Brand
AdviewII™
Company
AMERICAN DIAGNOSTIC CORP
Model
9005SPCN
Catalog number
9005SPCN
Device description
Adview2 SpO2 Finger Sensor,Reusable, Adult, 8’ cable Canada
Published
2018-11-13
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DQAOximeter

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DQAOximeterCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K160439000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K160439000SunTech CT40 Spot-check Vital Signs DeviceSuntech Medical2016-07-06DXN

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00634782094911PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00634782094911006347820949116347820949110634782094911

GMDN Terms#

Term, Definition table
TermDefinition
Pulse oximeter probe, reusableA photoelectric device applied externally to a body site, e.g., a fingertip, ear lobe, the bridge of nose, a toe, or the bridge of the foot of a paediatric or adult patient for the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in arterial blood using light detection. The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector, are received by an oximeter to which this device is connected. The oximeter displays the SpO2 values and may calculate/display other parameters, e.g., electrocardiogram (ECG). This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature41 Degrees Fahrenheit113 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
1-800-232-2670info@adctoday.com

Regulatory Flags#

DUNS number
108999095
Device count
1
Lot or batch
true
Serial number
true
Manufacturing date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00634782102258Adscope®608CFST608CFST2026-06-02
00634782603045ADC54202542022026-03-31
00634782603052ADC54203542032026-03-31
00634782603069ADC54204542042026-03-31
00634782603076ADC54205542052026-03-31
00634782098384Adscope®603-04W603-04W2026-03-30
00634782100209Adscope®608-12COP608-12COP2026-03-30
00634782100216Adscope®608-12G608-12G2026-03-30
00634782100223Adscope®608-12I608-12I2026-03-30
00634782100230Adscope®608-12ST608-12ST2026-03-30
00634782100247Adscope®608-12MBK608-12MBK2026-03-30
00634782100254Adscope®608-12RGBK608-12RGBK2026-03-30
00634782100261Adscope®608-12RGW608-12RGW2026-03-30
00634782100834Adscope®608-12BK608-12BK2026-03-30
00634782101190Adscope®608-01MBK608-01MBK2026-03-30
00634782101299Adsoft®602-078BK1Q602-078BK1Q2026-03-30
00634782101305Adsoft®602-078PR1Q602-078PR1Q2026-03-30
00634782101312Adsoft®602-078TQ1Q602-078TQ1Q2026-03-30
00634782101329Adsoft®602-078G1Q602-078G1Q2026-03-30
00634782101336Adsoft®602-078Y1Q602-078Y1Q2026-03-30

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
06924054300623BERRY®SHANGHAI BERRY ELECTRONIC TECH CO., LTD.DQA2026-06-04
06931973410890CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-06-02
08720256776567Corsano CardioWatch 287-2 SystemCorsano Health B.V.DQA2026-06-02
06920485308450BSXMEDShenzhen BSX Technology Electronics Co., Ltd.DQA2026-06-01
10884521855397NellcorCovidien LPDQA2026-05-29
10884521855403NellcorCovidien LPDQA2026-05-29
B3944060056010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3944670047010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945000030010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945300046010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945300054010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945300054020WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945600013020WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048020WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048030WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048040WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048050WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048060WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048070WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048080WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048090WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700048100WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700051020WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700063010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700064010WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
B3945700068020WVSM Pro, Wireless Vital Signs Monitor ProfessionalATHENA GTX, INC.DQA2026-05-27
09551028900069Cables and SensorsXINMED SDN. BHD.DQA2026-04-22
06924054300586BERRY®SHANGHAI BERRY ELECTRONIC TECH CO., LTD.DQA2026-04-22
08052990320318MIRMIR MEDICAL INTERNATIONAL RESEARCH SPADQA2026-04-03