Attain Ability™ MRI SureScan™

Primary DI
00643169601772
Brand
Attain Ability™ MRI SureScan™
Company
MEDTRONIC, INC.
Model
419688
Device description
LEAD 419688 MRI CANT US
Published
2016-02-26
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
MR Conditional
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DTBpermanent pacemaker Electrode
OJXDrug eluting permanent left ventricular (lv) pacemaker electrode

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DTBPermanent Pacemaker ElectrodeCardiovascular3
OJXDrug Eluting Permanent Left Ventricular (Lv) Pacemaker ElectrodeUnknown3

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
P080006085
P080006147

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
P080006085MEDTRONIC ATTAIN ABILITY MODEL 4196 LEADMedtronic, Inc.2009-04-07OJX
P080006147MEDTRONIC ATTAIN ABILITY MODEL 4196 LEADMedtronic, Inc.2009-04-07OJX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00643169601772PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00643169601772006431696017726431696017720643169601772

GMDN Terms#

Term, Definition table
TermDefinition
Endocardial pacing leadA sterile, implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted pulse generator to the heart; it is not intended to conduct defibrillation impulses. It may also transmit electrical responses from the heart back to the pacemaker. The electrode end is normally placed through a vein to contact the wall of one of the heart's chambers (endocardium), and the other end is connected to the pacemaker. It is typically impregnated with a steroid (e.g., dexamethasone) intended to elute into the tissues to reduce inflammation.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length88Centimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Temperature59 Degrees Fahrenheit86 Degrees Fahrenheit
Storage Environment Temperature77 Degrees Fahrenheit77 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(800)633-8766Corporate.UDI@medtronic.com

Regulatory Flags#

DUNS number
006261481
Device count
1
Combination product
true
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00824846005445NA12T76R12026-07-30
00824846005469NABB2Q31R112026-07-30
00824846005667NABB9R33R162026-07-30
00824846006022NABB12S36R2026-07-30
00824846007944NABB12W03R12026-07-30
00613994746627ATTAIN SELECT™ II624890D022016-07-16
00763000862336MyCareLink™249552026-07-26
00763000060374LINQ II™LNQ222020-07-18
00763000422615SYNCHROMED®II8637-402021-04-11
00763000634094SYNCHROMED® II8637-202022-08-11
00763000634100SYNCHROMED® II8637-402022-08-11
00643169508149SYNCHROMED® II8637-202016-04-27
00643169508156SYNCHROMED® II8637-402016-04-27
00643169630505SYNCHROMED® II8637-202018-08-17
00643169630512SYNCHROMED® II8637-402018-08-17
00643169100824SYNCHROMED ® II8637-402016-04-27
00643169100831SYNCHROMED ® II8637-202016-04-27
00199150084036MiniMed Flex Starter KitMMT-8076B2026-07-19
00199150084043MiniMed Flex Starter KitMMT-8076C2026-07-19
00199150084050MiniMed Extended Supply KitMMT-445B2026-07-19

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00763000812058NAMEDTRONIC, INC.DTB2025-04-12
00763000180010Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180027Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180058Sprint Quattro Secure S MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180126Sprint Quattro Secure S MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180133Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180140Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180157Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180249Sprint Quattro Secure™MEDTRONIC, INC.DTB2024-11-04
00763000180355Sprint Quattro Secure™MEDTRONIC, INC.DTB2024-11-04
00763000740252SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2022-12-11
00763000740269SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2022-12-11
00763000740276SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2022-12-11
00763000059477NAMEDTRONIC, INC.DTB2018-12-28
00763000130794SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2018-10-11
04035479157821EFH-6F-WBIOTRONIK SE & Co. KGDTB2017-11-22
04035479157838EFH-6F-WBIOTRONIK SE & Co. KGDTB2017-11-17
00643169410954CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00643169410961CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00643169448940CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00643169448957CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00763000014636CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014650CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014674CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014681CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014698CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014704CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014728CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00643169633735CapSureFix Novus MRI™ SureScan®MEDTRONIC, INC.DTB2017-06-02
00643169633759CapSureFix Novus MRI™ SureScan®MEDTRONIC, INC.DTB2017-06-02