DiamondTemp™ FASTR RF Generator

Primary DI
00763000482190
Brand
DiamondTemp™ FASTR RF Generator
Company
MEDTRONIC, INC.
Model
CEDTG200
Device description
GENERATOR CEDTG200 FASTR RF US
Published
2021-10-02
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
OAECatheter, percutaneous, cardiac ablation, for treatment of atrial fibrillation

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
OAECatheter, Percutaneous, Cardiac Ablation, For Treatment Of Atrial FibrillationUnknown3

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
P200028003

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
P200028003DiamondTemp Ablation SystemMedtronic, Inc.2021-01-28OAE

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00763000482190PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00763000482190007630004821907630004821900763000482190

GMDN Terms#

Term, Definition table
TermDefinition
Radio-frequency ablation system generatorA mains electricity (AC-powered) device designed to generate radio-frequency (RF) electrical current used to create heat via an electrode(s) in a precise location, at a controlled temperature, for focal ablation of non-cardiac tissues (e.g., non-cardiac nerves, tumours, precancerous tissue); it may be intended for coagulation however it is not intended for electrosurgical cutting. The generator connects via a delivery cable to an electrosurgical ablation probe/catheter (not included) to transmit the RF electrical current to the operative site; it might additionally be intended to heat an electrode tip (electrocautery).

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity15 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Handling Environment Temperature-22 Degrees Fahrenheit140 Degrees Fahrenheit
Special Storage Condition, Specify00Keep dry
Storage Environment Temperature59 Degrees Fahrenheit86 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(800)633-8766Corporate.UDI@medtronic.com

Regulatory Flags#

DUNS number
006261481
Device count
1
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00199150062911N/AAFR-002132026-09-04
00613994733658Pulmonary Wedge Pressure Catheter1500752016-06-12
00613994811639Z2Z26JR4052016-06-11
00613994813053Z2Z26EBU3552016-06-11
00643169356979Z2Z27FR40D2016-04-25
00643169356993Z2Z27AL75D2016-06-11
00643169559820Euphora™EUP1510X2016-04-25
00643169559837Euphora™EUP1512X2016-04-11
00643169559844Euphora™EUP1515X2016-04-11
00643169559851Euphora™EUP1520X2016-04-11
00643169559868Euphora™EUP2006X2016-04-11
00643169559875Euphora™EUP2010X2016-04-11
00643169559905Euphora™EUP2020X2016-04-11
00643169559912Euphora™EUP2025X2016-04-25
00643169559929Euphora™EUP2030X2016-04-11
00643169559936Euphora™EUP22506X2016-04-11
00643169559943Euphora™EUP22510X2016-04-11
00643169559950Euphora™EUP22512X2016-04-11
00643169559967Euphora™EUP22515X2016-04-11
00643169559974Euphora™EUP22520X2016-04-11

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
05415067054463Ampere™ST. JUDE MEDICAL, INC.OAE2026-08-19
05415067054661TactiSys™ST. JUDE MEDICAL, INC.OAE2026-08-19
00763000954345NAMEDTRONIC, INC.OAE2026-08-14
10846835026726Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026733Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026764Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026795Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026825Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026856Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026887Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
10846835026917Dual Energy Thermocool Smarttouch SF CatheterBiosense Webster IncOAE2026-07-09
00763000954321NAMEDTRONIC, INC.OAE2026-04-30
00199150003709Sphere-9™ CatheterMEDTRONIC, INC.OAE2026-02-20
00763000993269Sphere-9™ CatheterMEDTRONIC, INC.OAE2026-02-08
05415067051943N/AST. JUDE MEDICAL, INC.OAE2025-10-31
05415067051950TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067051998TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067052018TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067052025TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067052056TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067052063TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067052216TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
05415067052223TactiFlex™ Sensor Enabled™ST. JUDE MEDICAL, INC.OAE2025-10-29
00763000998301HexaGen™ RF GeneratorMEDTRONIC, INC.OAE2025-08-30
00763000998332HexaFlow™ Irrigation PumpMEDTRONIC, INC.OAE2025-08-30
00763000998363HexaPulse™ PF GeneratorMEDTRONIC, INC.OAE2025-08-30
00763000995003N/AMEDTRONIC, INC.OAE2025-04-12
20763000954363N/AMEDTRONIC, INC.OAE2025-02-22
05415067046734Ampere™ST. JUDE MEDICAL, INC.OAE2025-01-14
05415067046741Ampere™ST. JUDE MEDICAL, INC.OAE2025-01-14