Elyra

Primary DI
00801741225239
Brand
Elyra
Company
C. R. Bard, Inc.
Model
7082001
Catalog number
7082001
Device description
Elyra Thulium Fiber Laser System
Published
2026-05-06
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEXPowered laser surgical instrument

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEXPowered Laser Surgical InstrumentGeneral, Plastic Surgery2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00801741225239PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00801741225239008017412252398017412252390801741225239

GMDN Terms#

Term, Definition table
TermDefinition
General/multiple surgical solid-state laser systemA mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam intended for general surgery and/or multiple specialized surgical applications (non-dedicated), which may include treatment of vascular diseases. It vaporizes/ablates soft tissue with moderate haemostasis, little charring, and a thin zone of necrosis. It includes a light source, delivery/positioning device(s), and controls/foot-switch and emits a midinfrared wavelength. It does not include frequency doubling technology.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Weight82Kilogram

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Fragile, handle with care
Special Storage Condition, Specify00Keep dry
Special Storage Condition, Specify00Stacking limit by number
Special Storage Condition, Specify00This way up
Storage Environment Atmospheric Pressure80 KiloPascal106 KiloPascal
Storage Environment Humidity20 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius50 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
+1(844)823-5433medical.information@bd.com

Regulatory Flags#

DUNS number
016898496
Device count
1
Kit
true
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00801741050817Leg Bag1505071505072020-09-23
00801741076039Catheter Stabilization DeviceVFDSPVFDSP2020-09-22
00801741076053Catheter Stabilization DeviceVFDSSPVFDSSP2020-09-22
00801741076077Catheter Stabilization DeviceFOL0100FOL01002020-09-22
00801741076091Catheter Stabilization DeviceFOL0101FOL01012020-09-22
00801741076114Catheter Stabilization DeviceFOL0102FOL01022020-09-22
00801741076145Catheter Stabilization DeviceFOL0105FOL01052020-09-22
00801741127625Bard® Leg Bag Holders1501111501112016-08-10
00801741127632Bard® Leg Bag Holders1501211501212016-08-10
00801741127649Bard® Leg Bag Holders1501311501312016-08-10
00801741137419Bard® Wide Leg Bag Straps1621101621102018-02-06
00801741137426Bard® Wide Leg Bag Straps1622101622102018-02-06
00801741137433Bard® Wide Leg Bag Straps1623101623102018-02-06
00801741215902StatLock UrologicalSTATURO25STATURO252020-10-23
00801741231025PureWickPW300PCPW300PC2026-05-07
00801741234514PureWickPWA300HPWA300H2026-05-07
00801741225246Elyra708200270820022026-05-06
00801741231537PureWickPWKIT03HPWKIT03H2026-05-06
10801741239219PureWickPWF030KXSPWF030KXS2026-05-05
00801741225253Elyra708211570821152026-05-05

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07290110124175FemiLift Sterile SleeveALMA LASERS LTD.GEX2026-07-26
EOBN210188S0NAOBERON GmbH Fiber TechnologiesGEX2026-07-22
08800020109439TRI-BEAM ARMJeisys Medical Inc.GEX2026-07-21
08800020111845P-NAIN SYSTEMJeisys Medical Inc.GEX2026-07-21
008164690217041150-50TLASER PERIPHERALS, LLCGEX2026-07-20
00816995027850Fraxel FTXSOLTA MEDICALGEX2026-07-20
00816995027867Fraxel FTXSOLTA MEDICALGEX2026-07-20
00816995027874Fraxel FTXSOLTA MEDICALGEX2026-07-20
00816995027904Fraxel FTXSOLTA MEDICALGEX2026-07-20
06974851082079BVLASERNanjing Bestview Laser S&T Co.,Ltd.GEX2026-07-16
06974851082086BVLASERNanjing Bestview Laser S&T Co.,Ltd.GEX2026-07-16
06974851088019BVLASERNanjing Bestview Laser S&T Co.,Ltd.GEX2026-07-16
08800020106322TRI-BEAMJeisys Medical Inc.GEX2026-07-16
08800020109446TRI-BEAM HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109453TRI-BEAM HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109460TRI-BEAM HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109477TRI-BEAM HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109484TRI-BEAM HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109491TRI-BEAM HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109507TRI-BEAM PRO HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109514TRI-BEAM PRO HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109521TRI-BEAM PRO HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109538TRI-BEAM PRO HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109545TRI-BEAM PRO HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109552TRI-BEAM PRO HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109651Edge HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109668Edge HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109675Edge HandpieceJeisys Medical Inc.GEX2026-07-16
08800020109682Edge Guide TipJeisys Medical Inc.GEX2026-07-16
08800020109699Edge Guide TipJeisys Medical Inc.GEX2026-07-16