ARROW

Primary DI
00801902002983
Brand
ARROW
Company
TELEFLEX INCORPORATED
Model
IPN000066
Catalog number
AI-07077-G
Device description
7.5 Fr. 110 cm Infusion Port Thermodilution Catheter
Published
2016-09-16
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DYGCATHETER, FLOW DIRECTED

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DYGCatheter, Flow DirectedCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K833918000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K833918000INFUSION PORT BALLOON THERMODILUTIONCritikon Company, LLC1984-01-30DYG

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
60801902002985PackageGS15In Commercial Distribution
00801902002983PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
6080190200298560801902002985
00801902002983008019020029838019020029830801902002983

GMDN Terms#

Term, Definition table
TermDefinition
Pulmonary artery catheter, thermal dilutionA flexible tube with an inflatable balloon at its distal tip designed to be introduced percutaneously into the venous system via a central vein and advanced to the pulmonary artery, to measure/monitor haematological parameters (e.g., pulmonary arterial pressures, intermittent cardiac output, cardiac index) using thermal dilution techniques; it may also be intended for venous blood sampling. Also referred to as a Swan-Ganz catheter, it is typically used in conjunction with a parent device (e.g., blood pressure transducer) [not included], and includes an exit port for the solution and an electrical component (e.g., thermistor) for temperature measurements. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Catheter Gauge7.5French
Length110Centimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Store at normal room temperature away from direct exposure to light. Prolonged exposure to fluorescent light, sunlight or heat will damage the balloon

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(919)544-8000CS@TELEFLEX.COM

Regulatory Flags#

DUNS number
002348191
Device count
1
Lot or batch
true
Expiration date on label
true
Contains natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10801902222920ARROWIPN931154CV-15703-E2026-05-20
10801902222937ARROWIPN931155CV-158022026-05-20
10801902222944ARROWIPN931156CV-16702-E2026-05-20
10841495149792QUIKCLOT6366362026-05-18
10841156105907VSIIPN00174679602020-01-27
10841156105914VSIIPN00174979612020-01-27
10841156105921VSIIPN00175279622020-02-06
10841156105938VSIIPN00175679642020-01-27
10841156105945VSIIPN00175979652020-02-06
10841156105952VSIIPN00176379712020-01-27
14026704942456RUSCH221800-000160221800-0001602026-05-15
14026704942463RUSCH221800-000180221800-0001802026-05-15
14026704942470RUSCH221800-000200221800-0002002026-05-15
14026704942487RUSCH221800-000220221800-0002202026-05-15
14026704942494RUSCH221800-000240221800-0002402026-05-15
14026704942500RUSCH221800-000120221800-0001202026-05-15
14026704942517RUSCH221800-000140221800-0001402026-05-15
10801902226096ARROWIPNB00593ASK-15703-BFL2026-05-14
10801902226102ARROWIPNB00594ASK-12703-BFL2026-05-14
14026704921321WECKIPN928663HOL2LG2025-08-25

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00885403522270Swan-GanzBecton, Dickinson And CompanyDYG2026-05-30
00885403522348SWAN-GANZ CCOMBO VBecton, Dickinson And CompanyDYG2026-05-30
00885403522386Swan-GanzBecton, Dickinson And CompanyDYG2026-05-30
00690103218282SWAN-GANZ VIPEdwards Lifesciences LLCDYG2026-03-16
00690103218602SWAN-GANZ TRUE SIZEEdwards Lifesciences LLCDYG2026-03-16
00690103218626SWAN-GANZ TRUE SIZEEdwards Lifesciences LLCDYG2026-03-16
00690103218633SWAN-GANZ TRUE SIZEEdwards Lifesciences LLCDYG2026-03-16
00690103000382SWAN-GANZ TRUE SIZEEdwards Lifesciences LLCDYG2026-03-16
50690103218287SWAN-GANZ VIPEdwards Lifesciences LLCDYG2026-03-16
50690103218638SWAN-GANZ TRUE SIZEEdwards Lifesciences LLCDYG2026-03-16
00690103217094Swan-GanzEdwards Lifesciences LLCDYG2025-07-11
00690103219371SWAN GANZEdwards Lifesciences LLCDYG2024-08-30
00690103219289SWAN GANZEdwards Lifesciences LLCDYG2024-08-30
00690103219388SWAN-GANZEdwards Lifesciences LLCDYG2024-08-05
10801902206333ARROWTELEFLEX INCORPORATEDDYG2022-10-20
10801902206432ARROWTELEFLEX INCORPORATEDDYG2022-10-20
10801902206456ARROWTELEFLEX INCORPORATEDDYG2022-10-20
20801902206330ARROWTELEFLEX INCORPORATEDDYG2022-10-20
20801902206439ARROWTELEFLEX INCORPORATEDDYG2022-10-20
20801902206453ARROWTELEFLEX INCORPORATEDDYG2022-10-20
10801902209372ARROWTELEFLEX INCORPORATEDDYG2022-05-20
20801902209379ARROWTELEFLEX INCORPORATEDDYG2022-05-20
10801902208979ARROWTELEFLEX INCORPORATEDDYG2022-03-18
20801902208976ARROWTELEFLEX INCORPORATEDDYG2022-03-18
10801902206647ARROWTELEFLEX INCORPORATEDDYG2022-03-14
10801902206654ARROWTELEFLEX INCORPORATEDDYG2022-03-14
10801902206661ARROWTELEFLEX INCORPORATEDDYG2022-03-14
10801902206678ARROWTELEFLEX INCORPORATEDDYG2022-03-14
10801902206715ARROWTELEFLEX INCORPORATEDDYG2022-03-14
10801902206722ARROWTELEFLEX INCORPORATEDDYG2022-03-14