Javelin

Primary DI
00810005662604
Company
NVISION BIOMEDICAL TECHNOLOGIES, INC.
Model
TB-1000T-JG40
Device description
Instrument: 40mm Targeting Jig Drill Guide. The Javelin Tailor’s Bunion Fixation System is a single-use bone fixation device intended to be permanently implanted. The system consists of a titanium alloy plate and screws that provide fixation for the 5th metatarsal.
Published
2021-02-02
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Related Records

Regulatory Flags

DUNS number
047486041
Device count
1
DM exempt
true
Premarket exempt
true
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
false
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
true

Identifiers

IdentifierTypeAgencyPackage quantityStatus
00810005662604PrimaryGS10

Identifiers And Packaging

IdentifierTypeAgencyPackage quantityPackage typeContains DIDiscontinue dateStatus
00810005662604PrimaryGS10

Product Codes

CodeNameClassSpecialtyRegulationImplantMalfunction reporting
FZXGuide, Surgical, Instrument1General, Plastic Surgery878.4800NEligible

Premarket Submissions

No records found.

Premarket Details

No records found.

GMDN Terms

TermDefinition
General internal orthopaedic fixation system implantation kitA collection of instruments and devices intended to be used for the placement of an internal orthopaedic fixation system into or onto all types of bones (e.g., bones of limbs, spine, pelvis, or craniomaxillofacial). It is a non-dedicated device that includes various metallic and/or plastic reusable devices [e.g., retractors, rods, clamps, drills, pins, saws, screwdrivers, guides, trials, impactors] intended to be used for the implantation of any type of internal orthopaedic fixation system; the implant(s) is not included. This is a reusable device.

Device Sizes

No records found.

Storage And Handling

No records found.

Sterilization Methods

Method
Moist Heat or Steam Sterilization

Contacts

PhoneEmail
210-545-3713diana@nvisionbiomed.com

Other Devices From This Company

Primary DIBrandModelCatalogPublished
00810005667227TrigonWD-1001T-WSLA2025-12-19
00810005668163VertexSTK-1000T-PIN2025-12-18
00810135964180VertexSTK-20-16-162025-12-17
00810135963268ImpactPP-1000T-0322025-09-24
00810135963282ImpactPP-1000T-0422025-09-24
00810135963329ImpactPP-1001T-CUT42025-09-24
00810135963374ImpactPP-1001T-CUT32025-09-24
00810135963404ImpactPP-1000T-DEP342025-09-24
00810135963411ImpactPP-1001T-SLAP2025-09-24
00810135963640ImpactKWIRE-14-127S2025-09-24
00810135963657ImpactINST-1000T-M2502025-09-24
00810135963336ImpactPP-1000T-3012025-09-23
00810135963343ImpactPP-1000T-4012025-09-23
00810135963169ImpactPP-1001T-3002025-09-22
00810135963183ImpactPP-1001T-4002025-09-22
00810135963251ImpactPP-1000T-3002025-09-22
00810135963275ImpactPP-1000T-4002025-09-22
00810135963381ImpactPP-1000T-2002025-09-22
00810135963619ImpactPP-30-502025-09-22
00810135963626ImpactPP-40-502025-09-22

Other Devices Sharing Product Codes

Primary DIBrandCompanyProduct codePublished
08800200200079Drain-TGJSR MEDICAL CO., LTD.FZX2026-03-23
08800200200086Drain-TGJSR MEDICAL CO., LTD.FZX2026-03-23
00889024706965PSN 10MM M/L SHIFT BLOCKZimmer, Inc.FZX2026-03-19
03662663143462MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143479MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143486MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143493MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143509MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143516MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143523MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
03662663143530MaxAn Anterior Cervical Plate SystemHighridge Medical, LLCFZX2026-03-17
00763000885212n/aMEDTRONIC SOFAMOR DANEK, INC.FZX2026-03-16
00840277133410Innomed, Inc.INNOMED, INC.FZX2026-03-11
10705034578866N/AMedos International SàrlFZX2026-03-05
10705034578873N/AMedos International SàrlFZX2026-03-05
10705034578880N/AMedos International SàrlFZX2026-03-05
10705034578897N/AMedos International SàrlFZX2026-03-05
00841435120402TecometTECOMET INC.FZX2026-02-27
09421038411889Adj Dist Fem Alignment Guide – CartilageENZTEC LIMITEDFZX2026-02-27
09421038411896Adj Dist Fem Alignment Guide – PaddleENZTEC LIMITEDFZX2026-02-27
09421038411902Sagittal Alignment Connector - PivotENZTEC LIMITEDFZX2026-02-27
09421038411919Sagittal Alignment Connector - Pivot with FanENZTEC LIMITEDFZX2026-02-27
09421038411926Dist Fem Cut Block Connector – 8mmENZTEC LIMITEDFZX2026-02-27
09421038411933Dist Fem Cut Block Connector – 9mmENZTEC LIMITEDFZX2026-02-27
09421038411940Dist Fem Cut Block Connector – 10mmENZTEC LIMITEDFZX2026-02-27
09421038411957Dist Fem Cut Block Slot Connector – 8mmENZTEC LIMITEDFZX2026-02-27
09421038411964Dist Fem Cut Block Slot Connector – 9mmENZTEC LIMITEDFZX2026-02-27
09421038411971Dist Fem Cut Block Slot Connector – 10mmENZTEC LIMITEDFZX2026-02-27
09421038411988Dist Fem Cut Block – 1.27mmENZTEC LIMITEDFZX2026-02-27
09421038411995IM Rod – 8mm x 135mmENZTEC LIMITEDFZX2026-02-27