Aristotle

Primary DI
00818075010035
Brand
Aristotle
Company
SCIENTIA VASCULAR LLC
Model
14-300-002
Catalog number
A14-300-002
Device description
Guidewire- Support
Published
2020-02-24
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DQXWire, Guide, Catheter

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DQXWire, Guide, CatheterCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K173235000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K173235000Aristotle 14 Guidewire, 200cm, Soft Profile, Aristotle 14 Guidewire, 200cm, Support Profile, Aristotle 14 Guidewire, 300cm, Soft Profile, Aristotle 14 Guidewire, 300cm, Support ProfileScientia Vascular, LLC2018-01-22DQX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00818075010035PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00818075010035008180750100358180750100350818075010035

GMDN Terms#

Term, Definition table
TermDefinition
Cardiac/peripheral vascular guidewire, single-useA long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Keep dry, keep away from heat

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
888-385-9016info@scientiavascular.com

Regulatory Flags#

DUNS number
011234178
Device count
1
Lot or batch
true
Expiration date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00818075010080Plato27BPL273-150-0012016-08-24
00818075011179Aristotle01862A18-200-0012025-08-01
00818075011186Aristotle01863A18-200-0022025-08-01
00818075011193Aristotle01864A18-200-0032025-08-01
00818075011209SocratesSC038-156-0012025-05-27
00818075011216SocratesSC038-127-0012025-05-27
00818075010059Volo14-200-002V14-200-0022020-03-03
00818075010042Volo14-200-001V14-200-0012020-02-24
00818075010066Volo14-300-001V14-300-0012020-02-24
00818075010073Volo14-300-002V14-300-0022020-02-24
00818075010776SocratesSC038-156-0012023-11-14
00818075010790SocratesTS-254-1102023-11-14
00818075011025SocratesSC038-127-0012023-11-14
00818075010233Aristotle14-200-003Z14-200-0032023-09-25
00818075010240Aristotle14-200-004Z14-200-0042023-09-25
00818075010257Aristotle14-300-003Z14-300-0032023-09-25
00818075010264Aristotle14-300-004Z14-300-0042023-09-25
00818075010455Plato17-160-000PL17-160-0002023-01-26
00818075010462Plato17-160-045PL17-160-0452023-01-26
00818075010479Plato17-160-090PL17-160-0902023-01-26

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00884450589977SplashWire™Merit Medical Systems, Inc.DQX2026-06-02
07649989542021SmartGUIDE deflectable hydrophilic guidewire Artiria Medical SADQX2026-03-02
07640142811305Guidewire 0.025 6/270cm angled Straub Medical AGDQX2022-06-30
07640142811312SET Aspirex™ S 6F 110cmStraub Medical AGDQX2022-06-30
07640142811329SET Aspirex™ S 6F 135cmStraub Medical AGDQX2022-06-30
07640142811336SET Aspirex™ S 8F 85cmStraub Medical AGDQX2022-06-30
07640142811343SET Aspirex™ S 8F 110cmStraub Medical AGDQX2022-06-30
07640142811350SET Aspirex™ S 10F 110cmStraub Medical AGDQX2022-06-30
07640142811855SET Rotarex™S 6 F x 110 cmStraub Medical AGDQX2022-05-04
07640142811862SET Rotarex™S 6 F x 135 cm Straub Medical AGDQX2022-05-04
07640142811879SET Rotarex™S 8 F x 85 cm Straub Medical AGDQX2022-05-04
07640142811886SET Rotarex™S 8 F x 110 cmStraub Medical AGDQX2022-05-04
10193489078022NAMICMEDLINE INDUSTRIES, INC.DQX2022-02-24
30193489067044NAMICMEDLINE INDUSTRIES, INC.DQX2021-06-03
07613327508499Synchro SELECTStryker CorporationDQX2020-10-20
07613327508512Synchro SELECTStryker CorporationDQX2020-10-20
07613327508529Synchro SELECTStryker CorporationDQX2020-10-20
07613327508581Synchro SELECTStryker CorporationDQX2020-10-20
07613327508628Synchro SELECTStryker CorporationDQX2020-10-20
07613327508635Synchro SELECTStryker CorporationDQX2020-10-20
07640142810575SET Rotarex®S 6F 110cm (Straub Medical®)Straub Medical AGDQX2020-01-31
07640142810582SET Rotarex®S 6F 135cm (Straub Medical®)Straub Medical AGDQX2020-01-31
07640142810599SET Rotarex®S 8F 85cm (Straub Medical®)Straub Medical AGDQX2020-01-31
07640142810605SET Rotarex®S 8F 110 cm (Straub Medical®)Straub Medical AGDQX2020-01-31
07613327459647Synchro2Stryker CorporationDQX2019-06-20
07613327459661Synchro2Stryker CorporationDQX2019-06-20
08498840011874VYGONVygon CorporationDQX2019-04-08
08498840011881VYGONVygon CorporationDQX2019-04-08
08498840011898VYGONVygon CorporationDQX2019-04-08
08498840011911VYGONVygon CorporationDQX2019-04-08