NA

Primary DI
00840682107174
Brand
NA
Company
GE PARALLEL DESIGN, INC.
Model
i12L-RS
Device description
i12L-RS
Published
2016-07-15
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
ITXTransducer, ultrasonic, diagnostic
IYNSystem, imaging, pulsed doppler, ultrasonic
IYOSystem, imaging, pulsed echo, ultrasonic
LLZSystem, image processing, radiological

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ITXTransducer, Ultrasonic, DiagnosticRadiology2
IYNSystem, Imaging, Pulsed Doppler, UltrasonicRadiology2
IYOSystem, Imaging, Pulsed Echo, UltrasonicRadiology2
LLZSystem, Image Processing, RadiologicalRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K121063000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K121063000VIVID S5 DIAGNOSTIC ULTRASOUND SYSTEM, VIVID S6 DIAGNOSTIC ULTRASOUND SYSTEMGe Medical System Israel , Ltd.2012-08-21IYN

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00840682107174PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00840682107174008406821071748406821071740840682107174

GMDN Terms#

Term, Definition table
TermDefinition
Surgical ultrasound imaging transducerA hand-held ultrasound imaging transducer assembly designed to be positioned within a surgical site for localized intraoperative imaging applications. It is sometimes referred to as a surgical probe or fingertip probe. It steers, focuses, and detects the ultrasound beam and resulting echoes either mechanically or electronically. This group of devices includes ultrasound imaging transducer assemblies used with A-mode, B-mode, M-mode, Doppler, colour Doppler (CD), and duplex (combination imaging, Doppler and/or colour flow) scanning capabilities. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity0 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature-40 Degrees Celsius70 Degrees Celsius
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity0 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-40 Degrees Celsius70 Degrees Celsius

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
623906971
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00195278002730NAML4-20VN-DH44901AU2021-11-18
00840682105231NA4C-D2016-07-15
00840682105262NA3S-RS2016-07-15
00840682113311NA5S2016-07-15
00840682115230NA8L2016-07-15
00840682107051NA10S-RS2016-07-15
00840682107129NA8L-RS2016-07-15
00840682107143NA7S-RS2016-05-31
00840682105248NA4C2016-07-15
00840682113045NAM4S2016-07-15
00840682113205NA7S2016-07-15
00840682113281NA3V2016-07-15
00840682115216NA5CS2016-07-15
00840682115223NA3S2016-07-15
00840682115254NA3.5C2016-07-15
00840682115247NAi12L2016-07-15
00840682112598NA3V-D2016-07-15
00195278002723NAML4-20-DH44901AT2021-11-18
00840682142366NA6Vc-D2020-08-07
00840682108676NAC4-8-D2016-07-15

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00889024713390ROSA® ShoulderOrthosoft IncLLZ2026-10-15
B037FFSMD0Synapse MobilityResolutionMD Inc.LLZ2026-10-15
B037NLIVD0Nicolab Image ViewerResolutionMD Inc.LLZ2026-10-15
B037RESMDD0ResolutionMDResolutionMD Inc.LLZ2026-10-15
00860013868918MICSI-PETMicroStructure Imaging, Inc.LLZ2026-10-14
00745426000059MiPACS V5Medicor ImagingLLZ2026-10-12
00198953083246VolusonGE Healthcare Austria GmbH & Co OGIYO2026-10-09
00198953083246VolusonGE Healthcare Austria GmbH & Co OGIYN2026-10-09
00198953083246VolusonGE Healthcare Austria GmbH & Co OGITX2026-10-09
00198953083253VolusonGE Healthcare Austria GmbH & Co OGIYO2026-10-09
00198953083253VolusonGE Healthcare Austria GmbH & Co OGITX2026-10-09
00198953083253VolusonGE Healthcare Austria GmbH & Co OGIYN2026-10-09
00198953083260VolusonGE Healthcare Austria GmbH & Co OGIYO2026-10-09
00198953083260VolusonGE Healthcare Austria GmbH & Co OGIYN2026-10-09
00198953083260VolusonGE Healthcare Austria GmbH & Co OGITX2026-10-09
06948941160022Bladder ScannerMeda Co., LtdIYO2026-10-08
06948941160022Bladder ScannerMeda Co., LtdITX2026-10-08
75401622522132Synthesis Vision ViewerSynthesis Health Intelligence IncLLZ2026-10-08
00198953200421EchoPACGE Vingmed Ultrasound A/SLLZ2026-10-07
00198953200438EchoPACGE Vingmed Ultrasound A/SLLZ2026-10-07
17540262200126Change Healthcare Stratus Imaging Diagnostic ViewerChange Healthcare Canada CompanyLLZ2026-10-05
00855683006821AquaflexPARKER LABORATORIES INCIYO2026-10-01
00855683006845AquaflexPARKER LABORATORIES INCIYO2026-10-01
04719873009510"Esaote MyLabX1" Ultrasound Transducer_Linear ArrayQISDA CORPORATIONITX2026-10-01
04719873009534"Esaote MyLabX1" Ultrasound Transducer_Phased ArrayQISDA CORPORATIONITX2026-10-01
06975424191037Exact Medical Manufacturing, Inc.EXACT MEDICAL MANUFACTURING, INC.ITX2026-10-01
08809887550170EdgeFlow UH10CEdgeCare Inc.IYO2026-09-30
08809887550170EdgeFlow UH10CEdgeCare Inc.ITX2026-09-30
08809887550187EdgeFlow UH10EEdgeCare Inc.IYO2026-09-30
08809887550187EdgeFlow UH10EEdgeCare Inc.ITX2026-09-30