NA

Primary DI
00840682108362
Brand
NA
Company
GE Healthcare Austria GmbH & Co OG
Model
RIC5-9W
Device description
RIC5-9W
Published
2016-07-15
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
ITXTransducer, ultrasonic, diagnostic
IYNSystem, imaging, pulsed doppler, ultrasonic
IYOSystem, imaging, pulsed echo, ultrasonic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ITXTransducer, Ultrasonic, DiagnosticRadiology2
IYNSystem, Imaging, Pulsed Doppler, UltrasonicRadiology2
IYOSystem, Imaging, Pulsed Echo, UltrasonicRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K041688000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K041688000GE VOLUSON 730 PRO/EXPERT UNTRASOUND BT04General Electric Co.2004-07-08IYN

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00840682108362PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00840682108362008406821083628406821083620840682108362

GMDN Terms#

Term, Definition table
TermDefinition
Rectal ultrasound imaging system transducerAn ultrasound imaging transducer assembly specifically designed to be positioned within the rectum either manually or under endoscopic guidance. Included is a variety of single or multiple element transducer assembly configurations that convert electric voltages into an ultrasound beam. It steers, focuses, and detects the ultrasound beam and resulting echoes either mechanically or electronically. Also known as a rectal, transrectal, or prostate probe, it may incorporate a biopsy needle guidance channel as part of the transducer casing or housing assembly design. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity090 Percent (%) Relative Humidity
Handling Environment Temperature-10 Degrees Celsius50 Degrees Celsius
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity090 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius50 Degrees Celsius

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
300599979
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00195278814685VolusonExp BT24 to BT25 UPG59542912025-01-08
00195278770271VolusonExpert 22 BT2559361042025-01-07
00195278347473VolusonExpert 1858712232022-08-16
00195278347480VolusonExpert 2058685732022-08-16
00195278347497VolusonExpert 2258056922022-06-14
00195278016812VolusonE10 BT212020-09-21
00195278016829VolusonE8 BT212020-09-21
00195278016836VolusonE6 BT212020-09-21
00195278077592VolusonE BT20 to BT21 UPG2020-09-21
00195278713322RIC12-DRIC12-D59185802026-07-24
00840682108508NARIC5-9W-RS2016-07-15
00840682118040NARIC5-9-RS2016-07-15
00195278770158VolusonExpert 20 BT2559361052025-01-07
00195278770226VolusonExpert 18 BT2559361062025-01-07
00840682117968NA4D10L2016-07-15
00840682107723NARAB4-8L2016-07-15
00840682108324NARIC5-9H2016-07-15
00840682118125NARNA5-92016-07-15
00840682107655NA4DE7C2016-07-15
00840682107716NA4C-A2016-07-15

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
03701104600420T-LiteSONOSCANNERITX2026-08-25
04580826920721PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826920769PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826920806PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826926365PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826926396PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826926501PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826926518PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826926532PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826926556PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826927881PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826928291PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826928468PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826928628PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826928703PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
04580826928956PENTAX MedicalPENTAX MEDICAL CORPORATIONITX2026-08-25
08800010500840SonoSync+SAMSUNG MEDISON CO., LTD.IYN2026-08-18
08800010500840SonoSync+SAMSUNG MEDISON CO., LTD.IYO2026-08-18
08800290029376CA2-13MSAMSUNG MEDISON CO., LTD.ITX2026-08-18
08800290036169PA2-9SSAMSUNG MEDISON CO., LTD.ITX2026-08-18
08800290036237BCC2-13SAMSUNG MEDISON CO., LTD.ITX2026-08-18
08800357291937V6 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYN2026-08-18
08800357291937V6 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2026-08-18
08800357291937V6 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-08-18
08800357300165V7 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYN2026-08-18
08800357300165V7 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-08-18
08800357300165V7 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2026-08-18
08800357308208V8 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-08-18
08800357308208V8 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2026-08-18
08800357308208V8 ONE Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYN2026-08-18