Voluson
Primary DI 00840682139168
Brand Voluson
Company GE Healthcare Austria GmbH & Co OG
Model VE8 BT19
Published 2018-08-20
Public version status New
Distribution status In Commercial Distribution
MRI safety Labeling does not contain MRI Safety Information
Rx true Product Codes# Code, Name table Code Name ITX Transducer, ultrasonic, diagnostic IYN System, imaging, pulsed doppler, ultrasonic IYO System, imaging, pulsed echo, ultrasonic
Product Code Classifications# Code, Device, Specialty table Code Device Specialty Class ITX Transducer, Ultrasonic, Diagnostic Radiology 2 IYN System, Imaging, Pulsed Doppler, Ultrasonic Radiology 2 IYO System, Imaging, Pulsed Echo, Ultrasonic Radiology 2
Identifiers And Packaging# Identifier, Type, Agency table Identifier Type Agency Package quantity Status 00840682139168 Primary GS1 0
Alternate GTIN / UPC / EAN Codes Source identifier, GTIN-14 normalized, UPC-A table Source identifier GTIN-14 normalized UPC-A EAN-13 00840682139168 00840682139168 840682139168 0840682139168
GMDN Terms# Term, Definition table Term Definition Rectal/vaginal ultrasound imaging transducer An invasive component of an ultrasound imaging assembly designed to be positioned within the vagina and/or rectum, either manually or under endoscopic guidance, for ultrasound imaging from within the vagina/rectum. Sometimes referred to as an ultrasound probe, it converts electric voltages into ultrasound which it transmits, detects resulting echoes, and transmits a proportional signal/data to another device for display; it does not include an integrated display. It may be intended for wired or wireless data transfer and may be intended for use with a dedicated ultrasound system or with an off-the-shelf device (e.g., smartphone) with dedicated software installed. This is a reusable device.
Storage And Handling# Type, Low, High table Type Low High Condition Handling Environment Temperature 18 Degrees Celsius 30 Degrees Celsius Handling Environment Temperature 64 Degrees Fahrenheit 86 Degrees Fahrenheit Storage Environment Temperature -10 Degrees Celsius 50 Degrees Celsius Storage Environment Temperature 14 Degrees Fahrenheit 122 Degrees Fahrenheit
Regulatory Flags# DUNS number 300599979 Device count 1 Serial number true Manufacturing date on label true Other Devices From This Company# Other Devices Sharing Product Codes# Primary DI, Brand, Company table Primary DI Brand Company Product code Published 00850050934233 EndoSound® EVS Probe Endosound, Inc. ITX 2026-06-01 00850050934240 EndoSound® EVS SideBeam 5103 Endosound, Inc. IYO 2026-06-01 00850050934240 EndoSound® EVS SideBeam 5103 Endosound, Inc. IYN 2026-06-01 00850050934257 EndoSound® Coax Transducer Extension Connector (TEC) Endosound, Inc. IYO 2026-06-01 00850050934257 EndoSound® Coax Transducer Extension Connector (TEC) Endosound, Inc. IYN 2026-06-01 00850050934264 EndoSound® EVS SideBeam 5105 (4 pouches) Endosound, Inc. IYO 2026-06-01 00850050934264 EndoSound® EVS SideBeam 5105 (4 pouches) Endosound, Inc. IYN 2026-06-01 04987670105937 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. ITX 2026-06-01 04987670105937 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. IYO 2026-06-01 04987670105937 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. IYN 2026-06-01 04987670106194 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. ITX 2026-06-01 04987670106194 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. IYO 2026-06-01 04987670106194 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. IYN 2026-06-01 08800013510112 L8-17H Alpinion Medical Systems Co., Ltd. IYO 2026-05-29 08800013510112 L8-17H Alpinion Medical Systems Co., Ltd. ITX 2026-05-29 08800013510112 L8-17H Alpinion Medical Systems Co., Ltd. IYN 2026-05-29 00198953121382 Voluson GE Ultrasound Korea Ltd. IYO 2026-05-28 00198953121382 Voluson GE Ultrasound Korea Ltd. IYN 2026-05-28 00198953121382 Voluson GE Ultrasound Korea Ltd. ITX 2026-05-28 00850055427075 HYDROS TRUS Probe PROCEPT BioRobotics Corporation ITX 2024-09-06 08033737713037 THD Procto Software System THD SPA ITX 2021-07-19 08052461860046 Echolight S.p.a. ECHOLIGHT SPA IYO 2021-03-05 08056304452658 MyLab 9 eXP ESAOTE SPA IYN 2018-02-19 08056304452658 MyLab 9 eXP ESAOTE SPA ITX 2018-02-19 08056304452603 MyLabEight eXP ESAOTE SPA IYO 2017-04-03 08056304452603 MyLabEight eXP ESAOTE SPA IYN 2017-04-03 08056304452610 MyLabEight ESAOTE SPA ITX 2017-04-03 08056304452610 MyLabEight ESAOTE SPA IYO 2017-04-03 08056304452597 MyLabSeven ESAOTE SPA ITX 2017-02-24 08056304452597 MyLabSeven ESAOTE SPA IYO 2017-02-24