AccuCARE Accessory Kit

Primary DI
00841436103015
Brand
AccuCARE Accessory Kit
Company
CIVCO MEDICAL INSTRUMENTS CO., INC.
Model
610-1293-5
Catalog number
610-1293-5
Device description
Sterile 18GA grid (2), sterile (81.3 x 91.4cm) polyethylene drape (2), non-sterile (2 x 14cm) endocavity balloon (2) for use with AccuCARE Positioning and Stabilizing equipment
Published
2017-08-22
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
ITXTransducer, ultrasonic, diagnostic
IWJSystem, applicator, radionuclide, manual
JAQSystem, applicator, radionuclide, remote-controlled

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ITXTransducer, Ultrasonic, DiagnosticRadiology2
IWJSystem, Applicator, Radionuclide, ManualRadiology1
JAQSystem, Applicator, Radionuclide, Remote-ControlledRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K131161000
K970513000
K992152000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K131161000EX3 STEPPER, CLASSIC STEPPER, MULTI-PURPOSE WORKSTATION STEPPER; MICRO-TOUCH, MICRO-TOUCH LP, MULIT-PURPOSE WORKSTATION,CIVCO Medical Instruments Co., Inc.2013-09-17ITX
K970513000GENERAL PURPOSE TRANDUCER COVERCIVCO Medical Instruments Co., Inc.1997-06-20ITX
K992152000GENERAL PURPOSE TRANSDUCER STANDOFF, BIOPSY TRANSDUCER STANDOFF, BI-PLANE ENDOCAVITY TRANSDUCER STANDOFFCIVCO Medical Instruments Co., Inc.1999-08-17ITX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00841436103015PrimaryGS10
80841436103011Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00841436103015008414361030158414361030150841436103015
8084143610301180841436103011

GMDN Terms#

Term, Definition table
TermDefinition
Manual brachytherapy systemAn assembly of therapeutic, independent devices, manually brought together and intended to deliver a palliative or therapeutic radiation dose to an anatomical region from radionuclide sources. Medical personnel manually place multiple radioactive sources in appliances and applicators for either permanent or temporary delivery at the topical, interstitial, intraluminal, or intracavitary brachytherapy treatment site. The radioactive source(s) assemblies contain naturally occurring, reactor produced, or accelerator produced radionuclides that are in the form of, e.g., encapsulated, embedded, sealed, wire, plated or foil sources, contained radioactive liquids, gels or gas.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length3.5Inch
Width3.2Inch

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Keep Away from Sunlight
Storage Environment Temperature52 Degrees Fahrenheit85 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(319)248-6502regulatory@civco.com

Regulatory Flags#

DUNS number
134614411
Device count
1
Kit
true
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00841436125482Needle Guide11820737118207372026-04-17
00841436108300TEE Kit811-050811-0502017-08-22
00841436108317TEE Kit811-051811-0512017-08-22
00841436108324TEE Kit811-052811-0522017-08-22
00841436108331TEE Kit811-053811-0532017-08-22
00841436108348TEE Kit811-054811-0542017-08-22
00841436108355TEE Kit811-055811-0552017-08-22
00841436108362TEE Kit811-056811-0562017-08-22
00841436108379TEE Kit811-057811-0572017-08-22
00841436111133Laparostat810-212810-2122017-08-22
10841436122655Needle Guide667-187667-1872025-12-31
10841436122662Needle Guide667-188667-1882025-12-31
10841436126240Needle Guide610-1557610-15572025-12-31
10841436126257Needle Guide610-1558610-15582025-12-31
00841436122894Verza Guidance System639-064639-0642025-12-31
00841436125345Verza Guidance System667-196667-1962025-12-31
00841436125802Verza Guidance SystemH48062APH48062AP2025-12-31
00841436125826Needle Guidance SystemH48062ARH48062AR2025-12-31
00841436125840Needle Guidance SystemH48062ASH48062AS2025-12-31
00841436126274Verza Guidance System657-115657-1152025-12-31

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00816389028081MAASTRO Rectal Applicator Set, ø 26 mmVARIAN MEDICAL SYSTEMS, INC.JAQ2026-06-02
00850050934233EndoSound® EVS ProbeEndosound, Inc.ITX2026-06-01
04987670105937DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
04987670106194DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
B16556330328053126035Flexi-NeedleLiberty Medical , Inc.IWJ2026-06-01
B1655635032805302533Implant NeedleLiberty Medical , Inc.IWJ2026-06-01
B1655662032805302615Intrauterine TandemLiberty Medical , Inc.IWJ2026-06-01
B16558010327123126103Medium Prostate Brachytherapy KitLiberty Medical , Inc.IWJ2026-06-01
B16558010328010026067Medium Prostate Brachytherapy KitLiberty Medical , Inc.IWJ2026-06-01
B165580203270931260031Large Prostate Brachytherapy KitLiberty Medical , Inc.IWJ2026-06-01
B16558110328022826066Medium Prostate Brachytherapy Kit-metal hubLiberty Medical , Inc.IWJ2026-06-01
B16559050328053126091ButtonsLiberty Medical , Inc.IWJ2026-06-01
B16559060328053026074ButtonsLiberty Medical , Inc.IWJ2026-06-01
B16559090328053026060ButtonsLiberty Medical , Inc.IWJ2026-06-01
B16559100328053026079ButtonsLiberty Medical , Inc.IWJ2026-06-01
B16570160328053126101Flexi-NeedleLiberty Medical , Inc.IWJ2026-06-01
B16570170328053126102Flexi-NeedleLiberty Medical , Inc.IWJ2026-06-01
B16570940328053126107AdapterLiberty Medical , Inc.IWJ2026-06-01
00841365121579Best Medical InternationalBEST MEDICAL INTERNATIONAL, INC.IWJ2026-05-29
08800013510112L8-17HAlpinion Medical Systems Co., Ltd.ITX2026-05-29
00198953121382VolusonGE Ultrasound Korea Ltd.ITX2026-05-28
08056304455826MyLabC25ESAOTE SPAITX2025-12-10
08056304455833MyLabC30ESAOTE SPAITX2025-12-10
08056304455017MyLabA50ESAOTE SPAITX2025-07-07
08056304455215MyLabE85ESAOTE SPAITX2025-07-07
08056304455307MyLabA70ESAOTE SPAITX2025-07-07
08056304455437MyLabA50ESAOTE SPAITX2025-07-07
08056304455451MyLabA70ESAOTE SPAITX2025-07-07
08056304455635MyLabE80ESAOTE SPAITX2025-07-07
08056304455642MyLabE85ESAOTE SPAITX2025-07-07