Endocavity Balloon

Primary DI
00841436109079
Brand
Endocavity Balloon
Company
CIVCO MEDICAL INSTRUMENTS CO., INC.
Model
H46222LR
Catalog number
H46222LR
Device description
Non-sterile (2 x 14cm) endocavity balloon for use with B-K Medical 8658 (8558) and 8848, Best® Sonalis™, GE Healthcare ERB, Hitachi Aloka Medical EUP-U533, UST 672.5/7.5, Siemens Endo-P II (on SONOLINE Adara/Prima ultrasound system) and Terason 8B48 transducers
Published
2017-08-22
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
ITXTransducer, ultrasonic, diagnostic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ITXTransducer, Ultrasonic, DiagnosticRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K992152000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K992152000GENERAL PURPOSE TRANSDUCER STANDOFF, BIOPSY TRANSDUCER STANDOFF, BI-PLANE ENDOCAVITY TRANSDUCER STANDOFFCIVCO Medical Instruments Co., Inc.1999-08-17ITX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00841436109079PrimaryGS10
80841436109075Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00841436109079008414361090798414361090790841436109079
8084143610907580841436109075

GMDN Terms#

Term, Definition table
TermDefinition
Body-orifice ultrasound imaging transducer cover, image-enhancementA non-sterile sheath containing an extraluminal pocket/balloon portion intended to cover an ultrasound imaging system transducer (probe) used in natural body orifices (e.g., vagina, rectum), to both protect the transducer and improve image quality. The balloon portion is intended to, when filled with an aqueous solution (e.g., saline), displace air and provide an adjustable interface between the transducer and the anatomy of interest (e.g., prostate) to improve imaging. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length7.5Inch
Lumen/Inner Diameter0.83Inch

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Keep Away from Sunlight
Storage Environment Temperature52 Degrees Fahrenheit85 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(319)248-6502regulatory@civco.com

Regulatory Flags#

DUNS number
134614411
Device count
10
Kit
true
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10841436122662Needle Guide667-188667-188, 667-188-52025-12-31
00841436126311Tracking Bracket Starter Kit657-119657-1192025-12-31
00841436125482Needle Guide11820737118207372026-04-17
00841436108300TEE Kit811-050811-0502017-08-22
00841436108317TEE Kit811-051811-0512017-08-22
00841436108324TEE Kit811-052811-0522017-08-22
00841436108331TEE Kit811-053811-0532017-08-22
00841436108348TEE Kit811-054811-0542017-08-22
00841436108355TEE Kit811-055811-0552017-08-22
00841436108362TEE Kit811-056811-0562017-08-22
00841436108379TEE Kit811-057811-0572017-08-22
00841436111133Laparostat810-212810-2122017-08-22
10841436122655Needle Guide667-187667-1872025-12-31
10841436126240Needle Guide610-1557610-15572025-12-31
10841436126257Needle Guide610-1558610-15582025-12-31
00841436122894Verza Guidance System639-064639-0642025-12-31
00841436125345Verza Guidance System667-196667-1962025-12-31
00841436125802Verza Guidance SystemH48062APH48062AP2025-12-31
00841436125826Needle Guidance SystemH48062ARH48062AR2025-12-31
00841436125840Needle Guidance SystemH48062ASH48062AS2025-12-31

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00841517112011iLOOKFUJIFILM SONOSITE, INC.ITX2026-07-16
00841517112028iLOOKFUJIFILM SONOSITE, INC.ITX2026-07-16
00841517112035iLOOKFUJIFILM SONOSITE, INC.ITX2026-07-16
00841517112462iLOOKFUJIFILM SONOSITE, INC.ITX2026-07-16
00841517139018iLOOKFUJIFILM SONOSITE, INC.ITX2026-07-16
00860013043605EdgeLife TechnologiesEdge Life Technologies, LLCITX2026-07-10
00860013043612EdgeLife TechnologiesEdge Life Technologies, LLCITX2026-07-10
00841517112653rP19x/5-1 MHz ArmoredFUJIFILM SONOSITE, INC.ITX2026-06-24
00841517112660L12-3FUJIFILM SONOSITE, INC.ITX2026-06-24
00841517112677L15-4FUJIFILM SONOSITE, INC.ITX2026-06-24
00852619008041QT Scanner 2000Qt Imaging, Inc.ITX2026-06-24
00841517112646L15-4FUJIFILM SONOSITE, INC.ITX2026-06-23
00841517112639L12-3FUJIFILM SONOSITE, INC.ITX2026-06-22
00198953078716LOGIQGE Medical Systems (China) Co.,Ltd.ITX2026-06-10
00198953078754LOGIQGE Medical Systems (China) Co.,Ltd.ITX2026-06-10
00198953147009LOGIQGE Medical Systems (China) Co.,Ltd.ITX2026-06-10
00198953147016LOGIQGE Medical Systems (China) Co.,Ltd.ITX2026-06-10
00198953147351LOGIQGE Medical Systems (China) Co.,Ltd.ITX2026-06-10
00850050934233EndoSound® EVS ProbeEndosound, Inc.ITX2026-06-01
04987670105937DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
04987670106194DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
08800013510112L8-17HAlpinion Medical Systems Co., Ltd.ITX2026-05-29
00198953121382VolusonGE Ultrasound Korea Ltd.ITX2026-05-28
10841436122662Needle GuideCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2025-12-31
08056304455826MyLabC25ESAOTE SPAITX2025-12-10
08056304455833MyLabC30ESAOTE SPAITX2025-12-10
08056304455017MyLabA50ESAOTE SPAITX2025-07-07
08056304455215MyLabE85ESAOTE SPAITX2025-07-07
08056304455307MyLabA70ESAOTE SPAITX2025-07-07
08056304455437MyLabA50ESAOTE SPAITX2025-07-07