MasimoSET® LNCS® DCIv adult SpO2 Reusable Sensor

Primary DI
00843997004923
Brand
MasimoSET® LNCS® DCIv adult SpO2 Reusable Sensor
Company
MASIMO CORPORATION
Model
2924
Catalog number
2924
Device description
MasimoSET® LNCS® DCIv adult SpO2 Reusable Sensor
Published
2016-08-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DQAOximeter

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DQAOximeterCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K051212000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K051212000MODIFICATION TO LNCS OXIMETRY SENSORSMasimo Corporation2005-07-12DQA

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00843997004923PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00843997004923008439970049238439970049230843997004923

GMDN Terms#

Term, Definition table
TermDefinition
Pulse oximeter probe, reusableA photoelectric device applied externally to a body site, e.g., a fingertip, ear lobe, the bridge of nose, a toe, or the bridge of the foot of a paediatric or adult patient for the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in arterial blood using light detection. The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector, are received by an oximeter to which this device is connected. The oximeter displays the SpO2 values and may calculate/display other parameters, e.g., electrocardiogram (ECG). This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity5 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature-40 Degrees Celsius70 Degrees Celsius
Storage Environment Humidity5 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-40 Degrees Celsius70 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(949)297-7498TechService-US@masimo.com

Regulatory Flags#

DUNS number
780421038
Device count
1
Lot or batch
true
Manufacturing date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10843997011003Radius VSM48422026-02-23
10843997016015Radius VSM46952026-02-23
00843997019163Radius VSM90372026-02-23
00843997019019Patient SafetyNet Lite950972026-02-23
00843997011006Radius VSM48422026-02-23
00843997016018Radius VSM46952026-02-23
00843997015530Rad-G YI Multisite Reusable Sensor46532021-10-08
10843997003381LNCS26902024-08-16
10843997003398LNCS26912024-08-16
10843997003404LNCS26922024-08-16
10843997003411LNCS26942024-08-16
10843997004968MasimoSET LNCS® E1™ SpO2 Adult Pulse Oximeter Adhesive Sensor291829182016-08-24
10843997010921RD rainbow SET-240282020-09-03
10843997010938RD rainbow SET-240292020-09-03
10843997013496O343842020-09-03
00843997010825rainbow SET418341832023-02-13
00843997010818rainbow SET41822022-11-21
10843997002797MasimoSET® LNCS® Adtx-3 SpO2 Adult Pulse Oximeter Adhesive Sensor260126012016-08-24
10843997002803MasimoSET® LNCS® Pdtx-3 SpO2 Pediatric Pulse Oximeter Adhesive Sensor260226022016-08-24
10843997002810MasimoSET® LNCS® Inf-3 SpO2 Infant Pulse Oximeter Adhesive Sensor260326032016-08-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
04048675785910Masimo SpO2 Module for Vista 300/SShanghai Draeger Medical Instrument Co.,Ltd.DQA2026-07-13
00010939962218N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
00093351041099N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
00845717013550N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
00845717013567N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
06972040113849N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
06972040113856N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
06931973400563CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973400730CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973400785CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410326CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410333CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410340CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410364CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410371CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410388CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410395CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410401CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410418CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410425CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410432CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410449CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410456CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410647CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410678CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410685CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410692CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410715CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410722CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410739CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09