VitalPatch® Active Biosensor

Primary DI
00850490007146
Brand
VitalPatch® Active Biosensor
Company
Vital Connect, Inc.
Model
3012-01
Published
2017-05-04
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true
Single use
true

Product Codes#

Code, Name table
CodeName
DRGTransmitters And Receivers, Physiological Signal, Radiofrequency
DSIDetector And Alarm, Arrhythmia
MHXMonitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DRGTransmitters And Receivers, Physiological Signal, RadiofrequencyCardiovascular2
DSIDetector And Alarm, ArrhythmiaCardiovascular2
MHXMonitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)Cardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K152139000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K152139000Vital Connect Platform, HealthPatch MD, VitalPatchVitalconnect, Inc.2015-12-06DRG

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00850490007122PackageGS120In Commercial Distribution
00850490007153PackageGS15In Commercial Distribution
00850490007146PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00850490007122008504900071228504900071220850490007122
00850490007153008504900071538504900071530850490007153
00850490007146008504900071468504900071460850490007146

GMDN Terms#

Term, Definition table
TermDefinition
Electrocardiography telemetric monitoring systemAn assembly of devices designed to continuously measure and wirelessly transmit electrocardiographic (ECG) signals from a patient to a receiving location (e.g., central station, bedside monitor) for viewing. It typically consists of a portable transmitter with antenna and attached sensors (e.g., leads and electrodes) that are connected to the patient, as well as a receiver typically incorporated into a central station or bedside monitor that receives, consolidates, and displays the information. The system is typically used for ambulatory patients who require continuous monitoring (e.g., patients in step-down care areas).

Regulatory Flags#

DUNS number
944642730
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00850490007344VitalPatch 2.03037-013047-012019-07-25
00850490007511Holter Kit (Wi-Fi Only)2400-012400-012023-08-31
00850490007481VistaPhone8303-038303-032023-03-31
00850490007504VistaPhone Compact Cardiac Monitoring Kit1500-011400-022023-03-31
00850490007283VitalPatch Adhesive Overlay3801-013801-012019-03-26
00850490007467VistaPhone8303-028303-022021-01-15
00850490007252Vista Solution® 30-day Monitoring Kit9430-019430-012020-11-04
00850490007269Vista Solution® 10-day Evaluation Kit9410-019410-012020-11-04
00850490007313Vista Solution® 2.0 10-day Evaluation Kit9510-019510-012020-11-04
00850490007368VistaTablet™ 2.0 RELAY (W/O VCI Box)8102-018102-012020-11-04
00850490007238VitalPatch 2.03037-013037-012020-11-03
00850490007375VistaCenter6200-036200-032020-11-02
00850490007382VistaPoint Software User Interface6100-036100-032020-11-02
00850490007399VistaTablet8103-018103-012020-11-02
00850490007412Vista Solution 3 10-day Evaluation Kit961096102020-11-02
00850490007429VistaTablet8203-018203-012020-11-02
00850490007436VistaPhone8303-018303-012020-11-02
00850490007443VitalConnect 14-day Cardiac Monitoring Kit1400-021400-022020-11-02
00850490007450VitalPatch® RTM 4007-014007-012020-11-02
00850490007207VistaTablet8101-018101-012018-08-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00884838132320Patient Information Center iXPhilips Medizin Systeme Böblingen GmbHMHX2026-07-13
00884838132337Care AssistPhilips Medizin Systeme Böblingen GmbHMHX2026-07-13
00884838132337Care AssistPhilips Medizin Systeme Böblingen GmbHDSI2026-07-13
00884838132344Care AssistPhilips Medizin Systeme Böblingen GmbHDSI2026-07-13
00884838132344Care AssistPhilips Medizin Systeme Böblingen GmbHMHX2026-07-13
04048675723639Vista 300Shanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675723646Vista 300Shanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675785477Vista CMSShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675785484Vista CMSShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675785491Vista CMSShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675786108Vista CMSShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675797173Vista 300 SShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675797180Vista 300 SShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
04048675797197Vista 300 SShanghai Draeger Medical Instrument Co.,Ltd.MHX2026-07-13
00198953205716CARESCAPE Telemetry ServerGe Medical Systems Information Technologies, Inc.MHX2026-06-05
08720256776567Corsano CardioWatch 287-2 SystemCorsano Health B.V.DRG2026-06-02
04719875011016EZYPRO ECG RecorderSIGKNOW BIOMEDICAL CO., LTD.DRG2026-06-01
04719875011023EZYPRO ECG RecorderSIGKNOW BIOMEDICAL CO., LTD.DRG2026-06-01
04719875011030EZYPRO ECG RecorderSIGKNOW BIOMEDICAL CO., LTD.DRG2026-06-01
00884838119017Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119024Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119031Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119048Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119055Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119062Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119185Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119192Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119208Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119215Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28
00884838119222Telemetry AccessoriesPhilips Medizin Systeme Böblingen GmbHMHX2026-05-28