Stericide Peroxide Reagent Strips 811905B

GUDID 00851575007389

Reagent test strips used to measure the concentration of residual peroxide in rinse water from dialyzers and dialysate lines disinfected with peroxide/peracetic acid.

HACH COMPANY

Hydrogen peroxide device disinfectant/sterilant test strip
Primary Device ID00851575007389
NIH Device Record Key0cdd718c-f823-4150-83b7-44cc9f648c4e
Commercial Distribution StatusIn Commercial Distribution
Brand NameStericide Peroxide Reagent Strips
Version Model Number811905B
Catalog Number811905B
Company DUNS091381780
Company NameHACH COMPANY
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usetrue
Lot Batchtrue
Serial Numberfalse
Manufacturing Datefalse
Expiration Datetrue
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latextrue
RX Perscriptionfalse
OTC Over-The-Counterfalse

Customer Support Contacts

Phone970-278-4951
Emailetscustomerservice@hach.com

Device Dimensions

Length3.25 Inch

Operating and Storage Conditions

Storage Environment TemperatureBetween 60 Degrees Fahrenheit and 90 Degrees Fahrenheit

Device Identifiers

Device Issuing AgencyDevice ID
GS100851575007389 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

LIFDialyzer Reprocessing System

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusNew
Device Record StatusPublished
Public Version Number1
Public Version Date2020-04-22
Device Publish Date2020-04-14

Devices Manufactured by HACH COMPANY

00851575007389 - Stericide Peroxide Reagent Strips2020-04-22Reagent test strips used to measure the concentration of residual peroxide in rinse water from dialyzers and dialysate lines disinfected with peroxide/peracetic acid.
00851575007389 - Stericide Peroxide Reagent Strips2020-04-22 Reagent test strips used to measure the concentration of residual peroxide in rinse water from dialyzers and dialysate lines dis
00851575007020 - SteriChek® Residual Chlorine Reagent Strips2018-09-12 Reagent test strip for measuring the concentration of residual chlorine (i.e. from chlorine bleach) in rinse water following dis
00851575007044 - SteriChek® Peroxide Reagent Strips2018-09-12 Reagent test strips used to measure the concentration of residual peroxide in rinse water from dialyzers and dialysate lines dis
00851575007051 - SteriChek® Total Chlorine Test Kit2018-09-12 Reagent test kit used to measure low levels of total chlorine in feed water used to prepare dialysate.
00851575007068 - Sterichek® Total Chlorine Test Kit Refill2018-09-12 DPD reagent powder pillows refill, used with reagent test kit to measure low levels of total chlorine in feed water used to prep
00851575007075 - SteriChek® Residual Peroxide Reagent Strips2018-09-12 Reagent test strips used to measure the concentration of residual peroxide in rinse water from dialyzers and dialysate lines dis
00851575007105 - SteriChek® Blood Leak Reagent Strips2018-09-12 Reagent test strips used to test for the presence of blood in dialysate fluid during the hemodialysis procedure.
00851575007129 - SteriChek® Blood Leak Reagent Strips2018-09-12 Reagent test strips used to test for the presence of blood in dialysate fluid during the hemodialysis procedure.

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.