pNeuton

Primary DI
00853678006689
Brand
pNeuton
Company
AIRON CORPORATION
Model
58210
Catalog number
58210
Device description
Bacterial/Viral Filter, main line or expiratory
Published
2017-01-10
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
CAHFilter, Bacterial, Breathing-Circuit

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
CAHFilter, Bacterial, Breathing-CircuitAnesthesiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K925217000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K925217000MERIDIAN MEDICAL SYSTEMS BREATHING FILTERMerit Medical Systems, Inc.1993-01-26CAH

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00853678006689PackageGS150In Commercial Distribution
00853678006672PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00853678006689008536780066898536780066890853678006689
00853678006672008536780066728536780066720853678006672

GMDN Terms#

Term, Definition table
TermDefinition
Non-respiratory device ambient air filterA filter designed to be installed in a non-respiratory device to clean the ambient air that passes through it to facilitate device operation/management. It is composed of tightly woven materials which remove particulates/impurities and, depending on how the device is installed, reduce the concentration of impurities to or from the air. It is typically used in devices that draw in ambient air for use as part of their function (e.g., to cool electrical motors, liquidize air as in a flotation therapy bed, wash/disinfect surgical instruments), or devices that, having used the air as a drive gas, exhaust it into a room via the filter. After installation, this device cannot be reused.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length2.75Inch

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Temperature-4 Degrees Fahrenheit140 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
321-821-9433info@aironusa.com

Regulatory Flags#

DUNS number
015222912
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
true
Expiration date on label
true
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
true
Sterilization required before use
false

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00853678006733pNeuton Model A with 6ft Patient CircuitA200592025-12-19
00853678006726pNeuton Model A Start-up Kit with 8ft Patient CircuitA200602025-12-18
00853678006054pNeuton58001580012016-09-24
00853678006078MACS58011580112016-09-24
00853678006139pNeuton58035580352016-09-24
00853678006634pNeuton58006580062016-09-24
00853678006658MACS58021580212016-09-24
00853678006696pNeuton58201582012019-06-17
00853678006092pNeuton58051580512016-09-24
00853678006115pNeuton58031580312016-09-24
00853678006252miniFlow58406584062016-09-24
00853678006276miniFlow58405584052016-09-24
00853678006290miniFlow58404584042016-09-24
00853678006313miniFlow58403584032016-09-24
00853678006337miniFlow58402584022016-09-24
00853678006351miniFlow58401584012016-09-24
00853678006375miniFlow58400584002016-09-24
00853678006238miniFlow58407584072016-09-24
00853678006672pNeuton58210582102017-01-10
00853678006061pNeuton58001580012016-09-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08697645018150ENDURE INDUSTRIESENDURE INDUSTRIESCAH2026-04-17
08697645018167ENDURE INDUSTRIESENDURE INDUSTRIESCAH2026-04-17
08697645018174ENDURE INDUSTRIESENDURE INDUSTRIESCAH2026-04-17
08697645018181ENDURE INDUSTRIESENDURE INDUSTRIESCAH2026-04-17
10197344157938MEDLINEMEDLINE INDUSTRIES, INC.CAH2025-09-12
10197344157945MEDLINEMEDLINE INDUSTRIES, INC.CAH2025-09-12
10889483590591AirLife™AirLife Finland OyCAH2025-04-02
07640142190882EasyOne Filter SPNDD Medizintechnik AGCAH2022-12-09
07640142190899EasyOne Filter FTNDD Medizintechnik AGCAH2022-12-09
10193489339826Medline Industries, Inc.MEDLINE INDUSTRIES, INC.CAH2022-08-04
10193489139990MedlineMEDLINE INDUSTRIES, INC.CAH2022-08-03
09420012432339Fisher & Paykel HealthcareFISHER & PAYKEL HEALTHCARE LIMITEDCAH2022-08-02
10193489085600MedlineMEDLINE INDUSTRIES, INC.CAH2022-07-12
10193489025019MedlineMEDLINE INDUSTRIES, INC.CAH2022-06-10
10193489019452HYDRO-GUARD MINI BREATHING FILTER Intersurgical IncorporatedCAH2021-10-05
10190752141834AirLife™VYAIRE MEDICAL, INC.CAH2021-04-09
10190752136434Vital Signs™Vyaire GmbHCAH2021-04-02
10190752139589Vital Signs™AirLife Finland OyCAH2021-04-02
10190752135987Vital Signs™AirLife Finland OyCAH2021-03-05
10190752135994Vital Signs™AirLife Finland OyCAH2021-03-05
10190752136632Vital Signs™AirLife Finland OyCAH2021-03-05
10190752136793Vital Signs™AirLife Finland OyCAH2021-03-05
10190752136809Vital Signs™AirLife Finland OyCAH2021-03-05
10190752138094Vital Signs™VYAIRE MEDICAL, INC.CAH2021-03-05
10190752139107Vital Signs™AirLife Finland OyCAH2021-03-05
10190752139558Vital Signs™AirLife Finland OyCAH2021-03-05
10190752140080Vital Signs™AirLife Finland OyCAH2021-03-05
10190752140097AirLife™AirLife Finland OyCAH2021-03-05
10190752136724Vital SignsAirLife Finland OyCAH2021-03-01
10190752147171AirLife™AIRLIFECAH2020-02-04