Certus® 140

Primary DI
00853719006074
Brand
Certus® 140
Company
NEUWAVE MEDICAL, INC.
Model
2.45 GHz Ablation System
Catalog number
LK20cm - 15ga
Device description
LK20cm-15ga CertusLK Ablation Probe, 20 cm, 15 ga
Published
2016-09-18
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
MR Unsafe
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
NEYSYSTEM, ABLATION, MICROWAVE AND ACCESSORIES

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
NEYSystem, Ablation, Microwave And AccessoriesGeneral, Plastic Surgery2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00853719006074PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00853719006074008537190060748537190060740853719006074

GMDN Terms#

Term, Definition table
TermDefinition
Microwave ablation system probeA hand-held surgical instrument designed to connect to a microwave ablation system generator to deliver microwaves to a targeted operative site for localized soft-tissue ablation, typically to treat tumours and/or hydatid cysts. The probe includes a handle and an antenna, and might include a cooling mechanism (via water irrigation). The device is intended to be used in percutaneous, endoscopic (e.g., gastroscopic, laparoscopic), and open surgery procedures to ablate tissues. This is a single-use device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity15 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-40 Degrees Celsius55 Degrees Celsius

Sterilization Methods#

Method table
Method
Ethylene Oxide

Contacts#

Phone, Email table
PhoneEmail
+1(877)323-9283info@neuwave.com

Regulatory Flags#

DUNS number
809758878
Device count
1
Lot or batch
true
Expiration date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10818913020698NEUWAVEPRS35PRS352024-06-14
20818913020695NEUWAVEPRS35PRS352024-06-14
00818913020509NEUWAVEPRS15PRS152020-12-08
00853719006494NEUWAVERC17PKRC17PK2017-04-13
00853719006951NEUWAVENWA1US1NNWA1US1N2017-11-03
00853719006968NEUWAVENWC1US1RNWC1US1R2018-08-26
00818913020677NEUWAVEDR-001446CTBKT52021-10-14
00818913020196NEUWAVENWF1US1NNWF1US1N2017-09-22
00818913020257NEUWAVEAC-UPGRADEAC-UPGRADE2021-05-06
00853719006753NEUWAVENWC1US1NNWC1US1N2017-11-03
00818913020073NEUWAVENWF2HK1NNWF2HK1N2021-03-31
00818913020158NEUWAVENWF2SG1NNWF2SG1N2021-03-31
00818913020172NEUWAVENWF2CN1NNWF2CN1N2021-03-31
00818913020189NEUWAVEDR-000894DR-0008942021-03-31
00853719006005Certus® 1402.45 GHz Ablation SystemPR15cm - 17ga2016-09-18
00853719006012Certus® 1402.45 GHz Ablation SystemPR20cm - 17ga2016-09-18
00853719006029Certus® 1402.45 GHz Ablation SystemPR15cm - 15ga2016-09-18
00853719006036Certus® 1402.45 GHz Ablation SystemPR20cm - 15ga2016-09-18
00853719006043Certus® 1402.45 GHz Ablation SystemLK15cm - 17ga2016-09-18
00853719006050Certus® 1402.45 GHz Ablation SystemLK20cm - 17ga2016-09-18

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
06935650621319HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650621333HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650621357HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650621371HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622613HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622620HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622637HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622651HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622668HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622682HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622699HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650622729HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650623344HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650623351HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650624327HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650626048HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650626451HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
06935650626468HYGEAHygea Medical Technology Co., Ltd.NEY2025-09-08
05060359560971MicroBlate FineCREO MEDICAL LIMITEDNEY2025-05-05
05060359560490MicroBlate FineCREO MEDICAL LIMITEDNEY2025-05-05
06954414601015Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601022Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601039Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601046Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601053Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601060Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601077Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601084Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601107Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14
06954414601121Microwave Ablation AntennasCanyon Medical Inc.NEY2025-03-14