Home GUDID 00857334004309
Model 2402 Maestro Mobile Charger
Primary DI 00857334004309
Brand Model 2402 Maestro Mobile Charger
Company Reshape Lifesciences Inc.
Model 2402
Catalog number 2402
Device description The Model 2402 Mobile Charger (MC) is a non-sterile external component that is powered by a rechargeable, lithium-ion battery. The MC charges the Rechargeable Neuroregulator (RNR) when connected to a Transmit Coil positioned over the RNR. The MC also provides communication between the Clinician Programmer and RNR to allow up and down loading of data, display battery charge levels, indicate proper positioning of the Transmit Coil, alert patient to fault conditions, and allow for inactivation of therapy and turning off the RNR if needed.
Published 2015-04-17
Public version status Update
Distribution status Not in Commercial Distribution
MRI safety MR Unsafe
Rx true
Product Codes# Code, Name table Code Name PIM neuromodulator for obesity
Product Code Classifications# Code, Device, Specialty table Code Device Specialty Class PIM Neuromodulator For Obesity Unknown 3
Identifiers And Packaging# Identifier, Type, Agency table Identifier Type Agency Package quantity Status 00857334004309 Primary GS1 0
Alternate GTIN / UPC / EAN Codes Source identifier, GTIN-14 normalized, UPC-A table Source identifier GTIN-14 normalized UPC-A EAN-13 00857334004309 00857334004309 857334004309 0857334004309
GMDN Terms# Term, Definition table Term Definition Gastric contractility modulation system charger A dedicated battery-powered device used to wirelessly recharge the battery of a gastric contractility modulation (GCM) system's implanted pulse generator (e.g., through transcutaneous inductive energy transfer and usually by device recognition). The device may be used to recharge the pulse generator battery in the home by the patient.
Device Sizes# Type, Value, Unit table Type Value Unit Height 1.2 Inch Length 2 Inch Width 4.7 Inch
Storage And Handling# Type, Low, High table Type Low High Condition Storage Environment Atmospheric Pressure 70 KiloPascal 150 KiloPascal Storage Environment Humidity 10 Percent (%) Relative Humidity 90 Percent (%) Relative Humidity Storage Environment Temperature -10 Degrees Celsius 55 Degrees Celsius
Regulatory Flags# DUNS number 144998551 Device count 1 DM exempt true Lot or batch true Serial number true Manufacturing date on label true Other Devices From This Company# Primary DI, Brand, Model table Primary DI Brand Model Catalog Published 00850007764173 LAP-BAND® System Calibration Tube B-2017 B-2017 2020-12-01 00850007764210 GIBI HD B-2032 B-2032 2022-08-07 00850007764227 GIBI HD B-2036 B-2036 2022-08-07 00850007764234 GIBI HD B-2040 B-2040 2022-08-07 00857334004194 Model 1600 Maestro Programmer Cable 1600 1600 2015-04-17 00857334004200 Model 1620 AC Recharger 1620 1620 2015-04-17 00857334004217 Model 1660 Maestro Patient Transmit Coil Belt 1660 1660 2015-04-17 00857334004248 Model 1680 Torque Wrench 1680 1680 2015-04-17 00857334004262 Model 2002 Maestro Rechargeable Neuroregulator 2002 2002 2015-04-17 00857334004279 Model 2004 Maestro Implant Kit 2004 2004 2015-04-17 00857334004286 Model 2200A-47E Maestro Anterior Lead 2200A-47E 2200A-47E 2015-04-17 00857334004293 Model 2200P-47E Maestro Posterior Lead 2200P-47E 2200P-47E 2015-04-17 00857334004316 Model 2403-300 Maestro Clinician Transmit Coil 2403-300 2403-300 2015-04-17 00857334004323 Model 2403-60 Maestro Patient Transmit Coil 2403-60 2403-60 2015-04-17 00857334004347 Model 2404 Maestro Patient Kit 2404 2404 2015-04-17 00857334004354 Model 2502 Maestro Clinician Programmer 2502 2502 2015-04-17 00857334004361 Model 2504 Maestro Clinician Programmer Kit 2504 2504 2015-04-17
Other Devices Sharing Product Codes# Primary DI, Brand, Company table Primary DI Brand Company Product code Published 00857334004194 Model 1600 Maestro Programmer Cable Reshape Lifesciences Inc. PIM 2015-04-17 00857334004200 Model 1620 AC Recharger Reshape Lifesciences Inc. PIM 2015-04-17 00857334004217 Model 1660 Maestro Patient Transmit Coil Belt Reshape Lifesciences Inc. PIM 2015-04-17 00857334004248 Model 1680 Torque Wrench Reshape Lifesciences Inc. PIM 2015-04-17 00857334004262 Model 2002 Maestro Rechargeable Neuroregulator Reshape Lifesciences Inc. PIM 2015-04-17 00857334004279 Model 2004 Maestro Implant Kit Reshape Lifesciences Inc. PIM 2015-04-17 00857334004286 Model 2200A-47E Maestro Anterior Lead Reshape Lifesciences Inc. PIM 2015-04-17 00857334004293 Model 2200P-47E Maestro Posterior Lead Reshape Lifesciences Inc. PIM 2015-04-17 00857334004316 Model 2403-300 Maestro Clinician Transmit Coil Reshape Lifesciences Inc. PIM 2015-04-17 00857334004323 Model 2403-60 Maestro Patient Transmit Coil Reshape Lifesciences Inc. PIM 2015-04-17 00857334004347 Model 2404 Maestro Patient Kit Reshape Lifesciences Inc. PIM 2015-04-17 00857334004354 Model 2502 Maestro Clinician Programmer Reshape Lifesciences Inc. PIM 2015-04-17 00857334004361 Model 2504 Maestro Clinician Programmer Kit Reshape Lifesciences Inc. PIM 2015-04-17