Vycor Viewsite Brain Access System with Alignment Clip

GUDID 00859261006173

THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor and brain access devices of varying shapes and sizes designed for providing diagnostic and surgical access to various portions of the brain and spine. It has been designed to serve as a self-retaining retractor system for brain tissue. It is comprised of an introducer and a working channel or port that are secured by a spring-loaded latch. There is also an Alignment Clip (AC) included separately in the packaging that may be optionally attached to aid in the centering of third-party instrumentation, specifically navigational and image guided system (“IGS”) pointers or probes (“pointer”). Each VBAS device allows for the gentle retraction of tissue, visualization of the surgical site and for the manipulation of introduced instruments. The range of device sizes (width and length) provides various working channel sizes.

VYCOR MEDICAL, INC.

Neurosurgical retraction cannula
Primary Device ID00859261006173
NIH Device Record Keydcc1955e-7d70-4637-b395-a3ebc0134a8d
Commercial Distribution StatusIn Commercial Distribution
Brand NameVycor Viewsite Brain Access System with Alignment Clip
Version Model NumberTC211507AC
Company DUNS002586317
Company NameVYCOR MEDICAL, INC.
Device Count1
DM Exempttrue
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usetrue
Lot Batchtrue
Serial Numberfalse
Manufacturing Datefalse
Expiration Datetrue
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Device Identifiers

Device Issuing AgencyDevice ID
GS100859261006173 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

GZTRetractor, Self-Retaining, For Neurosurgery

Sterilization

Steralize Prior To Usefalse
Device Is Steriletrue

Device Entry Metadata

Public Version StatusNew
Device Record StatusPublished
Public Version Number1
Public Version Date2021-05-27
Device Publish Date2021-05-19

On-Brand Devices [Vycor Viewsite Brain Access System with Alignment Clip]

00859261006258THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006241THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006234THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006227THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006210THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006203THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006197THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006180THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006173THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006166THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006159THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor
00859261006142THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) WITH ALIGNMENT CLIP (AC) is a family of retractor

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.