SPINERY Needle

Primary DI
00860011603610
Brand
SPINERY Needle
Company
AXON SRL
Model
SP-BI1005
Device description
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.The needle is hollow and its inner space is divided into 3 concentric lumens:• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
Published
2024-05-27
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K223303000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K223303000Spinery™ RF Ablation SystemAxon Spine Medical System2023-08-30GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00860011603610PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00860011603610008600116036108600116036100860011603610

GMDN Terms#

Term, Definition table
TermDefinition
Percutaneous radio-frequency ablation probe, tumour-ablation, bipolarA semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound (US) guidance] to deliver radio-frequency current in a bipolar configuration from a system generator to coagulate/ablate tissues (excluding the CNS and heart) for the treatment of tumours (e.g., in the liver); in addition to percutaneous access it might also be intended for laparoscopic and/or open surgical use. It includes distal electrodes in a bipolar arrangement and may include temperature-sensing elements; the introduction cannula may be included. This is a single-use device.

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
439154305
Device count
1
Kit
true
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00860011603603SPINERY NeedleSP-BI07042024-05-31
00860011603627SPINERY ConnectionsSP-CD2024-05-31
00860011603696SPINERY ConnectionSP-CS2024-05-31
00860011603665SPINERY GeneratorSPINERY2024-05-27

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00197998302718Solventum™Solventum US LLCGEI2026-09-25
00724995269586Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269951Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269968Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00190776432300MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432317MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432324MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432430MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432447MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432454MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776431457MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432041MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432195MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432201MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776431181MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431198MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431204MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431211MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431228MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431235MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431242MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431259MillenniumAvalign Technologies, Inc.GEI2026-09-21
10840113236852BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236890BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236937BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237040BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237064BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237101BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237118BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237132BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21