CATS

Primary DI
00860412001541
Brand
CATS
Company
ZIEN MEDICAL TECHNOLOGIES, INC.
Model
CATS-D
Catalog number
CATS-D
Device description
The CATS-D Tonometer prism is intended to be used with Goldmann type tonometers for the measurements of intraocular pressure of the human eye.
Published
2022-10-12
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Product Codes#

Code, Name table
CodeName
HKYTonometer, Manual

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HKYTonometer, ManualOphthalmic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K203850000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K203850000CATS®-D Tonometer PrismCats Tonometer, LLC2021-06-14HKY

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00860412001558PackageGS14In Commercial Distribution
00860412001541PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00860412001558008604120015588604120015580860412001558
00860412001541008604120015418604120015410860412001541

GMDN Terms#

Term, Definition table
TermDefinition
Ophthalmic tonometer, manualAn ophthalmic, manually-operated, measuring instrument designed for determining the intraocular pressure (IOP) by exerting an external force in direct contact with the eye which provides a reading of the resistance of the tunica of the eye to deformation (the extent of corneal indentation) which is expressed in millimetre(s) of mercury (mmHg). This device (known as a contact type, e.g., a Schioetz or Perkins tonometer) is used in the diagnosis of glaucoma and may be hand-held or used in conjunction with a slit lamp.

Regulatory Flags#

DUNS number
017535668
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00850068519279SAM MedicalIO805IO8052026-05-07
00850068519309SAM MedicalIO806IO8062026-05-07
00850068519330SAM MedicalIO807IO8072026-05-07
B090MT630MorTan MT632026-02-17
B090MT2020MorTanMT202 2026-02-10
B090MT2021MorTanMT202 2026-02-10
B090XC2201450XO ConstrainXC2.20-1452026-02-03
B090XC2201451XO ConstrainXC2.20-1452026-02-03
00850068519231SAM Medical IO8422025-12-09
00850068519248SAM Medical IO847W-1P2025-12-09
00850068519255SAM Medical IO846W-1P2025-12-09
00850068519262SAM Medical IO845W-1P2025-12-09
10850068519238SAM Medical IO8422025-12-09
10850068519245SAM Medical IO847W-1P2025-12-09
10850068519252SAM Medical IO846W-1P2025-12-09
10850068519269SAM Medical IO845W-1P2025-12-09
B090P110900VentiV ScientificP11-090P11-0902025-11-24
B090P11090F0VentiV ScientificP11-090-FP11-090-F2025-11-24
B090P110901VentiV ScientificP11-090P11-0902025-11-24
B090P11090F1VentiV ScientificP11-090-FP11-090-F2025-11-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00841668146477KATENAKATENA PRODUCTS, INC.HKY2026-03-02
10841668146474KATENAKATENA PRODUCTS, INC.HKY2026-03-02
06430033851920iCare ST500ICARE FINLAND OYHKY2025-12-05
06430033852415iCare IC100ICARE FINLAND OYHKY2025-12-04
06430033852514iCare IC200ICARE FINLAND OYHKY2025-12-04
00812559012485" Ocu-Film® +"""REICHERT, INC.HKY2025-08-15
00812559012492"Ocu-Film® +"""REICHERT, INC.HKY2025-08-14
00812559012454Ocu-Dot® Tonometer Probes - 100 CountREICHERT, INC.HKY2025-08-12
00812559010900Tono-Vera® Tonometer Starter Kit, RechargeableREICHERT, INC.HKY2025-08-12
00812559011945Tono-Vera® Tonometer Starter Kit, AA BatteryREICHERT, INC.HKY2025-08-12
00812559012324Ocu-Dot® Tonometer Probes - 100 CountREICHERT, INC.HKY2025-08-12
00757770407309Bausch + LombBausch & Lomb IncorporatedHKY2024-12-30
00757770408856Bausch + LombBausch & Lomb IncorporatedHKY2024-12-30
00757770417629Bausch + LombBausch & Lomb IncorporatedHKY2024-12-30
00757770420803Bausch + LombBausch & Lomb IncorporatedHKY2024-12-30
00757770426867Bausch + LombBausch & Lomb IncorporatedHKY2024-12-30
06430033851784ST500 SmartCradleICARE FINLAND OYHKY2024-11-07
06430033851791ST500 AdapterICARE FINLAND OYHKY2024-11-07
06430033851807ST500 RemoteICARE FINLAND OYHKY2024-11-07
06430033851883iCare ST500ICARE FINLAND OYHKY2024-11-07
00887482112366Symmetry Allen-SchiotzASPEN SURGICAL PRODUCTS, INC.HKY2024-08-20
06430033851098iCare PATIENT2ICARE FINLAND OYHKY2024-04-23
06430033851104iCare PATIENT2ICARE FINLAND OYHKY2024-04-23
06430033851463iCare IC200ICARE FINLAND OYHKY2023-06-20
08800019600411Applanation Tonometer HT-5000Huvitz Co., Ltd.HKY2023-06-12
04560323648564TAKAGITAKAGI SEIKO CO.,LTD.HKY2023-06-09
03664188000138LuneauLUNEAU TECHNOLOGY OPERATIONSHKY2023-06-08
03664188000114LuneauLUNEAU TECHNOLOGY OPERATIONSHKY2023-06-08
00860000603805Automated Ophthalmics Softips AUTOMATED OPHTHALMICS, INC.HKY2022-11-17
00860412001558CATSZIEN MEDICAL TECHNOLOGIES, INC.HKY2022-10-12