Cassi

GUDID 00866479000152

The Cassi Rotational Core Biopsy System with Quadpoint Disposable is used to perform biopsy pro-cedures on multiple patients. Up to 7 biopsy cycles (1 mandatory pre-test and 6 biopsies) can be performed per patient. The Cassi system components and catalog numbers are: REF: CS2100-NT Cassi Rotational Core Biopsy Needle – 10 gauge 10 – Sterile single-use biopsy needles and sample trays; comprised of a 19 gauge x 2 cm length securing needle with 10 gauge cutting cannula with trocar REF: CS2120-NT Cassi Rotational Core Biopsy Needle – 12 gauge 10 – Sterile single-use biopsy needles and sample trays; comprised of a 19 gauge x 2 cm length securing needle with a 12 gauge cutting cannula with trocar REF: CS2001-CC-10 10 – Non-sterile single-use CO2 (carbon dioxide) canisters with caps REF:CS2001-BH 1 – Non-sterile limited reusable biopsy handle and 1 spare limited-use 9 – volt alkaline battery

SCION MEDICAL TECHOLOGIES, LLC

Soft-tissue biopsy needle, single-use
Primary Device ID00866479000152
NIH Device Record Key516b084b-4c2d-4f76-953e-ca8273f90435
Commercial Distribution StatusIn Commercial Distribution
Brand NameCassi
Version Model NumberCS-2001-CC-10
Company DUNS078473721
Company NameSCION MEDICAL TECHOLOGIES, LLC
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usefalse
Lot Batchtrue
Serial Numberfalse
Manufacturing Datetrue
Expiration Datefalse
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptionfalse
OTC Over-The-Counterfalse

Device Identifiers

Device Issuing AgencyDevice ID
GS100866479000152 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

KNWInstrument, Biopsy

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusUpdate
Device Record StatusPublished
Public Version Number3
Public Version Date2018-07-06
Device Publish Date2016-09-30

On-Brand Devices [Cassi]

00866479000152The Cassi Rotational Core Biopsy System with Quadpoint Disposable is used to perform biopsy pro-
00866479000145The Cassi Rotational Core Biopsy System with Quadpoint Disposable is used to perform biopsy pro-
10866479000135The Cassi Rotational Core Biopsy System with Quadpoint Disposable is used to perform biopsy pro-
10866479000128The Cassi Rotational Core Biopsy System is used to perform biopsy procedures on multiple patient

Trademark Results [Cassi]

Mark Image

Registration | Serial
Company
Trademark
Application Date
CASSI
CASSI
98581088 not registered Live/Pending
MISSION Corp.
2024-06-03
CASSI
CASSI
98177790 not registered Live/Pending
Kennedy Krieger Institute
2023-09-13
CASSI
CASSI
90593928 not registered Live/Pending
Gorlitz, Kristen R
2021-03-22
CASSI
CASSI
88070641 5916052 Live/Registered
Maison Battat Inc.
2018-08-08
CASSI
CASSI
85795165 4448999 Live/Registered
SCION MEDICAL LTD.
2012-12-05
CASSI
CASSI
78817080 not registered Dead/Abandoned
Conversational Computing Corporation
2006-02-16
CASSI
CASSI
78335271 3024509 Dead/Cancelled
SCION MEDICAL TECHNOLOGIES, LLC
2003-12-02
CASSI
CASSI
76630404 not registered Dead/Abandoned
Hallam, Cassiopeia
2005-02-07
CASSI
CASSI
73427323 1280726 Dead/Cancelled
American Chemical Society, The
1983-05-24

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.