Monitor Input Cable, Mikro-Cath to EP-Tracer System

Primary DI
00868924000267
Brand
Monitor Input Cable, Mikro-Cath to EP-Tracer System
Company
MILLAR INC.
Model
850-5148
Catalog number
850-5148
Device description
The 850-5148 cable is designed as an interface between the Millar Mikro-CathTM catheter (Part #825-0101-5), and the Schwarzer Cardiotek GmbH medical device as detailed below: EP-Tracer 38, EP-Tracer 70, EP-Tracer 102, when used with the following system configurations: EP-Tracer Portable, EP-Tracer Stationary, EP-Tracer ProCart. The 850-5148 cable is 10 feet long. The cable is supplied nonsterile.
Published
2021-07-16
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DRQAmplifier And Signal Conditioner, Transducer Signal

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DRQAmplifier And Signal Conditioner, Transducer SignalCardiovascular2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00868924000267PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00868924000267008689240002678689240002670868924000267

GMDN Terms#

Term, Definition table
TermDefinition
Transducer signal amplifierAn electronic device that increases current, voltage, or power to intensify the electrical signal sent to or received from a transducer (e.g., electroacoustic, electro-optical, electromechanical), sometimes providing impedance matching. It will provide an electrical interface between a physiological transducer and a patient monitor or patient monitoring system that is used to monitor pressures such as, noninvasive and invasive blood pressure, oesophageal pressures, urinary tract pressures, intrauterine pressures and intraocular pressures.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature59 Degrees Fahrenheit104 Degrees Fahrenheit
Storage Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-13 Degrees Fahrenheit158 Degrees Fahrenheit

Sterilization Methods#

Method table
Method
Ethylene Oxide

Contacts#

Phone, Email table
PhoneEmail
8326677100sales@millar.com

Regulatory Flags#

DUNS number
058269648
Device count
1
Lot or batch
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00868924000205Mikro-Cath Pressure Catheter825-0101825-01012016-10-03
00868924000212Pressure Control Unit PCU-2000PCU-2000880-01292016-09-30
00868924000229TC-510 Pressure Control UnitTC-510851-59182016-09-30
00868924000236Mikro-Tip Catheter Pulse TransducerSPT-301808-10192016-10-21

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00851725007399Central StationNihon Kohden Digital Health Solutions, LLCDRQ2025-06-30
04931921017159CNS-2101 Central MonitorNIHON KOHDEN CORPORATIONDRQ2023-10-30
04931921017166CNS-2101 Central MonitorNIHON KOHDEN CORPORATIONDRQ2023-10-01
00884838093188Avalon Toco+ MP TransducerPhilips Medizin Systeme Böblingen GmbHDRQ2021-03-08
00884838093195Avalon Ultrasound TransducerPhilips Medizin Systeme Böblingen GmbHDRQ2021-03-08
00884838093201Avalon ECG/IUP TransducerPhilips Medizin Systeme Böblingen GmbHDRQ2021-03-08
00884838093218Avalon Toco MP TransducerPhilips Medizin Systeme Böblingen GmbHDRQ2021-03-08
00884838093225Avalon Toco+ TransducerPhilips Medizin Systeme Böblingen GmbHDRQ2021-03-08
08714729882985LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729882992LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729883234LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729883241LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729883289LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729883296LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729883333LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729883340LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885825LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885832LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885863LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885870LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885900LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885917LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885955LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
08714729885962LABSYSTEM™ PROBOSTON SCIENTIFIC CORPORATIONDRQ2019-12-13
40841716101586ACIST RXi® Mini System OverpackACIST MEDICAL SYSTEMS, INC.DRQ2019-05-06
00884838020849SO2 Optical ModulePhilips Medizin Systeme Böblingen GmbHDRQ2018-12-18
10841716101769ACIST RXi® Mini MountACIST MEDICAL SYSTEMS, INC.DRQ2017-09-27
10841716101783ACIST RXi® Mini Processing UnitACIST MEDICAL SYSTEMS, INC.DRQ2017-09-27
10841716101790ACIST RXi® Mini Navvus InterfaceACIST MEDICAL SYSTEMS, INC.DRQ2017-09-27
30841716101770RXi® Mini Navvus Interface CableACIST MEDICAL SYSTEMS, INC.DRQ2017-09-27