BIO-CLAD ALL POLY CUP SYSTEM

Primary DI
00880304255890
Brand
BIO-CLAD ALL POLY CUP SYSTEM
Company
Biomet Orthopedics, LLC
Model
163466
Catalog number
163466
Published
2015-10-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
JDGProsthesis, hip, femoral component, cemented, metal
LPHPROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JDGProsthesis, Hip, Femoral Component, Cemented, MetalOrthopedic2
LPHProsthesis, Hip, Semi-Constrained, Metal/Polymer, Porous UncementedOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K770219000
K926107000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K770219000WATSON-FARRAR TOTAL HIP REPLACEMENTOrthopedic Equipment Co., Inc.1977-02-17JDG
K926107000ARCOM POLYETHYLENE ACETABULAR LINERS & COMPONENTSBiomet, Inc.1993-07-28LPH

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00880304255890PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00880304255890008803042558908803042558900880304255890

GMDN Terms#

Term, Definition table
TermDefinition
Non-constrained polyethylene acetabular linerA sterile, implantable component of a two-piece acetabulum prosthesis that is inserted into an acetabular shell prosthesis to provide the articulating surface with a femoral head prosthesis as part of a total hip arthroplasty (THA). It is made of polyethylene (includes hylamer, cross-linked polyethylene), and does not include a stabilizing component to limit the range of motion of the hip.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(800)348-9500customerservice@zimmerbiomet.com

Regulatory Flags#

DUNS number
129278169
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00880304474185Arcos® Modular Revision Hip System11-30210211-3021022015-10-24
00880304474246Arcos® Modular Revision Hip System11-30210111-3021012015-10-24
00880304539259Arcos® Modular Revision Hip System11-30210911-3021092015-10-24
00889024711280Jgrknt Reusable Fishmouth Perc GuideSSI008662SSI0086622026-08-25
00889024712034Percutaneous Soft Anchor Short 1.4mm GuideSSI008661SSI0086612026-08-25
00880304527386Active Articulation0100009900100009902020-05-15
00880304527393Active Articulation0100009910100009912020-05-15
00880304485020Active Articulation Hip SystemEP-200144EP-2001442015-11-03
00880304485037Active Articulation Hip SystemEP-200146EP-2001462015-11-03
00880304485044Active Articulation Hip SystemEP-200148EP-2001482015-10-24
00880304485051Active Articulation Hip SystemEP-200150EP-2001502015-10-24
00880304485068Active Articulation Hip SystemEP-200152EP-2001522015-10-24
00880304485075Active Articulation Hip SystemEP-200154EP-2001542015-10-24
00880304485082Active Articulation Hip SystemEP-200156EP-2001562015-10-24
00880304485099Active Articulation Hip SystemEP-200158EP-2001582015-10-24
00880304485105Active Articulation Hip SystemEP-200160EP-2001602015-10-24
00880304485112Active Articulation Hip SystemEP-200162EP-2001622015-10-24
00880304485129Active Articulation Hip SystemEP-200164EP-2001642015-11-04
00880304485136Active Articulation Hip SystemEP-200166EP-2001662015-10-24
00880304491328Active Articulation™ Dual Mobility Hip SystemXL-200144XL-2001442015-10-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07630030883576Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883583Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883590Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883606Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883613Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883620Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883637Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883644Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883651Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883668Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883675Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883682Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883699Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883705Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883712Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883729Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883736Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883743Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883750Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883767Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883774Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883781Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883798Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883804Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883811Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883828Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883835Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883842Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883859Mpact 3D Metal FoamMedacta International SALPH2026-09-04
07630030883866Mpact 3D Metal FoamMedacta International SALPH2026-09-04