LP RING LOC PROVISIONAL LINER

Primary DI
00880304311039
Brand
LP RING LOC PROVISIONAL LINER
Company
Biomet Orthopedics, LLC
Model
31-423555
Catalog number
31-423555
Published
2016-10-21
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
JDIProsthesis, hip, semi-constrained, metal/polymer, cemented

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JDIProsthesis, Hip, Semi-Constrained, Metal/Polymer, CementedOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K920639000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K920639000RX 90 ACETABULAR COMPONENT SYSTEMBiomet, Inc.1992-06-30JDI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00880304311039PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00880304311039008803043110398803043110390880304311039

GMDN Terms#

Term, Definition table
TermDefinition
Acetabulum prosthesis trial, reusableA copy of a final acetabular prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size and position of the final acetabular prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, is typically made of metal or polymer material and may be designed in the form of cages, shells, augments, or inserts. This is a reusable device intended to be sterilized prior to use.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)348-9500customerservice@zimmerbiomet.com

Regulatory Flags#

DUNS number
129278169
Device count
1
Lot or batch
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00880304474185Arcos® Modular Revision Hip System11-30210211-3021022015-10-24
00880304474246Arcos® Modular Revision Hip System11-30210111-3021012015-10-24
00880304539259Arcos® Modular Revision Hip System11-30210911-3021092015-10-24
00889024711280Jgrknt Reusable Fishmouth Perc GuideSSI008662SSI0086622026-08-25
00889024712034Percutaneous Soft Anchor Short 1.4mm GuideSSI008661SSI0086612026-08-25
00880304527386Active Articulation0100009900100009902020-05-15
00880304527393Active Articulation0100009910100009912020-05-15
00880304485020Active Articulation Hip SystemEP-200144EP-2001442015-11-03
00880304485037Active Articulation Hip SystemEP-200146EP-2001462015-11-03
00880304485044Active Articulation Hip SystemEP-200148EP-2001482015-10-24
00880304485051Active Articulation Hip SystemEP-200150EP-2001502015-10-24
00880304485068Active Articulation Hip SystemEP-200152EP-2001522015-10-24
00880304485075Active Articulation Hip SystemEP-200154EP-2001542015-10-24
00880304485082Active Articulation Hip SystemEP-200156EP-2001562015-10-24
00880304485099Active Articulation Hip SystemEP-200158EP-2001582015-10-24
00880304485105Active Articulation Hip SystemEP-200160EP-2001602015-10-24
00880304485112Active Articulation Hip SystemEP-200162EP-2001622015-10-24
00880304485129Active Articulation Hip SystemEP-200164EP-2001642015-11-04
00880304485136Active Articulation Hip SystemEP-200166EP-2001662015-10-24
00880304491328Active Articulation™ Dual Mobility Hip SystemXL-200144XL-2001442015-10-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
E31442100200SignatureMaterialise NVJDI2026-09-24
E31442100300SignatureMaterialise NVJDI2026-09-24
10885862015181AuraExactech, Inc.JDI2022-10-04
10885862015198AuraExactech, Inc.JDI2022-10-04
10885862015204AuraExactech, Inc.JDI2022-10-04
10885862015211AuraExactech, Inc.JDI2022-10-04
10885862013743NAExactech, Inc.JDI2022-09-20
10885862013750NAExactech, Inc.JDI2022-09-20
10885862022448NAExactech, Inc.JDI2022-09-19
10885862022455NAExactech, Inc.JDI2022-09-19
10885862029867NAExactech, Inc.JDI2022-09-19
10885862034038NovationExactech, Inc.JDI2022-09-19
10885862034045NovationExactech, Inc.JDI2022-09-19
10885862034052NovationExactech, Inc.JDI2022-09-19
10885862034069NovationExactech, Inc.JDI2022-09-19
10885862034076NovationExactech, Inc.JDI2022-09-19
10885862034083NovationExactech, Inc.JDI2022-09-19
10885862034090NovationExactech, Inc.JDI2022-09-19
10885862034106NovationExactech, Inc.JDI2022-09-19
10885862034113NovationExactech, Inc.JDI2022-09-19
10885862033598NovationExactech, Inc.JDI2022-08-25
10885862033604NovationExactech, Inc.JDI2022-08-25
10885862033611NovationExactech, Inc.JDI2022-08-25
10885862033628NovationExactech, Inc.JDI2022-08-25
10885862033635NovationExactech, Inc.JDI2022-08-25
10885862033642NovationExactech, Inc.JDI2022-08-25
10885862033741NovationExactech, Inc.JDI2022-08-25
10885862033758NovationExactech, Inc.JDI2022-08-25
10885862033765NovationExactech, Inc.JDI2022-08-25
10885862010551NAExactech, Inc.JDI2022-08-18