Invivo

Primary DI
00884838081758
Brand
Invivo
Company
Philips DS North America LLC
Model
4535-303-46291
Catalog number
453530346291
Device description
SensaVue Cart Assembly
Published
2020-04-17
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
MR Conditional
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
LNHSystem, nuclear magnetic resonance imaging

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
LNHSystem, Nuclear Magnetic Resonance ImagingRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K023130000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K023130000ELOQUENCE, INTEGRATED FUNCTIONAL IMAGING SYSTEMMri Devices Corp.2002-10-11LNH

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00884838081758PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00884838081758008848380817588848380817580884838081758

GMDN Terms#

Term, Definition table
TermDefinition
MRI system workstationA freestanding image processing workstation specifically designed to be networked with one or more magnetic resonance imaging (MRI) systems. An MRI workstation differs from the operator's console in that it does not contain the controls for the direct operation of the diagnostic imaging system. It is designed to receive and transmit data both on-line and off-line and is typically located at a site remote from the MRI system's operator console. It is configured to provide the capability to further process, manipulate and/or view patient images and information collected from one or more MRI systems.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Temperature-25 Degrees Celsius70 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(877)468-4861dynasupport@philips.com

Regulatory Flags#

DUNS number
118983916
Device count
1
DM exempt
true
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00884838072657Invivo989603208432016-09-23
00884838072664Invivo989603203332016-09-23
00884838072756Invivo989603203272016-09-23
00884838072763Invivo989603203282016-09-23
00884838072770Invivo989603208422016-09-23
00884838072787Invivo989603204212016-09-23
00884838072794Invivo989603203302016-09-23
00884838072800Invivo989603203312016-09-23
00884838072817Invivo989603203322016-09-23
00884838100114Invivo4535-302-233312020-04-17
00884838066991Invivo7840112016-09-23
00884838072558Invivo989603205282016-09-23
00884838072565Invivo989603203012016-09-23
00884838072572Invivo989603203022016-09-23
00884838073456Invivo989603208782016-09-23
00884838073463Invivo989603208792016-09-23
00884838081543Invivo7840122016-09-23
00884838082885Invivo989603210042017-07-28
00884838083592Invivo7840012016-09-23
00884838098459PhilipsdS FLEX-S 1.5T4598017299712021-06-11

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00884838129924AV Cardiovascular Suite V1Philips Medical Systems Nederland B.V.LNH2026-08-23
00816396022676WGS-100 Respiration PillowIVY BIOMEDICAL SYSTEMS, INC.LNH2026-08-03
00816396023550WGS-100 Wireless Gating SystemIVY BIOMEDICAL SYSTEMS, INC.LNH2026-08-03
00816396023567WGS-100 TransmitterIVY BIOMEDICAL SYSTEMS, INC.LNH2026-08-03
00816396023574WGS-100 Base StationIVY BIOMEDICAL SYSTEMS, INC.LNH2026-08-03
07090042059091nordicAktivaNordicneurolab ASLNH2026-08-03
00866463000496STAGESpintech, Inc.LNH2026-07-23
04068151086584LungMapsSiemens Healthineers AGLNH2026-06-24
04573596201367OASISFUJIFILM CORPORATIONLNH2026-05-29
04573596201398OASISFUJIFILM CORPORATIONLNH2026-05-29
04573596201404OASISFUJIFILM CORPORATIONLNH2026-05-29
04573596201411OASISFUJIFILM CORPORATIONLNH2026-05-29
04573596201435OASISFUJIFILM CORPORATIONLNH2026-05-29
04573596202159OASISFUJIFILM CORPORATIONLNH2026-05-29
08720168162595Mask DSPS®-PROSH set/5MACROMEDICS B.V.LNH2026-04-23
08720168162571Mask DSPS®-PROSHVRL set/5MACROMEDICS B.V.LNH2026-04-22
08720168162618Mask DSPS®-PROSHL set/5MACROMEDICS B.V.LNH2026-04-22
08720168162649Mask DSPS®-PROSHVR set/5MACROMEDICS B.V.LNH2026-04-22
08720168162748Mask DSPS®-PROH, set/5MACROMEDICS B.V.LNH2026-04-22
08720168162755Mask DSPS®-PRO, set/5MACROMEDICS B.V.LNH2026-04-22
08720168162854Mask DSPS®-PROSCVRL set/5MACROMEDICS B.V.LNH2026-04-22
08720168162861Mask DSPS®-PROSC set/5MACROMEDICS B.V.LNH2026-04-22
08720168162878Mask DSPS®-PROSCVR set/5MACROMEDICS B.V.LNH2026-04-22
08720168162885Mask DSPS®-PROSCL set/5MACROMEDICS B.V.LNH2026-04-22
08720168163356DSPS-Prominent® SH profile set/2MACROMEDICS B.V.LNH2026-04-22
08720168163387DSPS PRO Mask Shim Set HNSMACROMEDICS B.V.LNH2026-04-22
08720168163394DSPS PRO Mask Shim Set HOMACROMEDICS B.V.LNH2026-04-22
10841439114732PronumbraMEDTEC, INC.LNH2025-09-12
10841439114749PronumbraMEDTEC, INC.LNH2025-09-12
10841439114770PronumbraMEDTEC, INC.LNH2025-09-12