Orthomatch

Primary DI
00885556622087
Brand
Orthomatch
Company
Smith & Nephew, Inc.
Model
71436399
Catalog number
71436399
Device description
ORTHOMATCH CRUCIATE RETAINING IMPLANT IMPACTOR
Published
2017-06-08
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
JWHPROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JWHProsthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/PolymerOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K170648000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K170648000ANTHEM CR Total Knee SystemSmith & Nephew, Inc.2017-05-11JWH

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00885556622087PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00885556622087008855566220878855566220870885556622087

GMDN Terms#

Term, Definition table
TermDefinition
Orthopaedic implant impactorA metal and/or plastic hand-held manual surgical instrument designed to position an implant into the body. Its mode of application is by transmission of an impact force to drive the implant into its final position in the body. The proximal end is a handle usually designed to absorb the impact from a surgical hammer or mallet. The distal end is usually shaped to conform to the implant shape, which could be flat or anatomically curved, or shaped like a chisel handle to facilitate the positioning. This is a reusable device.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)238-7538GUDID@SMITH-NEPHEW.COM

Regulatory Flags#

DUNS number
045483575
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00885556832448Salto Talaris Total Ankle ProsthesisMJU048TMJU048T2023-02-02
00885556165560NA76515310765153102026-07-16
00885556923023NA76547001765470012026-07-16
00885556925089NA74034445740344452026-07-14
00885556925379CORIOGRAPHROB20032ROB200322026-07-08
00885556925386CORIOGRAPHROB20031ROB200312026-07-08
00885556904879EVOS70887105708871052026-06-25
00885556904923EVOS70897130708971302026-06-25
00885556906163EVOS70879090708790902026-06-25
00885556906170EVOS70879095708790952026-06-25
00885556906187EVOS70879100708791002026-06-25
00885556906194EVOS70879105708791052026-06-25
00885556906200EVOS70879110708791102026-06-25
00885556906217EVOS70879115708791152026-06-25
00885556906224EVOS70879120708791202026-06-25
00885556906231EVOS70879125708791252026-06-25
00885556906248EVOS70879130708791302026-06-25
00885556906255EVOS70879135708791352026-06-25
00885556906262EVOS70879140708791402026-06-25
00885556906279EVOS70879145708791452026-06-25

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08800017269726EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269733EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269740EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269757EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269764EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269771EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269788EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017269795EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-05-21
08800017260853EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260860EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260877EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260884EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260891EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260907EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260914EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260921EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260938EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260945EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260952EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260969EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260976EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260983EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017260990EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017261003EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017261010EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017261027EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017261034EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017261041EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017262178EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10
08800017262185EXULT Knee Replacement SystemCorentec Co., LtdJWH2020-01-10