Comprehensive® Reverse Shoulder Instrument

Primary DI
00887868504600
Brand
Comprehensive® Reverse Shoulder Instrument
Company
Biomet Orthopedics, LLC
Model
405809
Catalog number
405809
Published
2021-04-30
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
KWSPROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED
PHXshoulder prosthesis, reverse configuration

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
KWSProsthesis, Shoulder, Semi-Constrained, Metal/Polymer CementedOrthopedic2
PHXShoulder Prosthesis, Reverse ConfigurationOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K120121000
K132239000
K193373000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K120121000COMPREHENSIVE REVERSE SHOULDER-MINI BASEPLATEBiomet, Inc.2012-02-16PHX
K132239000COMPREHENSIVE REVERSE SHOULDER SCREWSBiomet Manufacturing Corp2013-09-06PHX
K193373000Comprehensive® Reverse ShoulderBiomet, Inc.2020-04-15PHX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00887868504600PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00887868504600008878685046008878685046000887868504600

GMDN Terms#

Term, Definition table
TermDefinition
Orthopaedic implant impactorA metal and/or plastic hand-held manual surgical instrument designed to position an implant into the body. Its mode of application is by transmission of an impact force to drive the implant into its final position in the body. The proximal end is a handle usually designed to absorb the impact from a surgical hammer or mallet. The distal end is usually shaped to conform to the implant shape, which could be flat or anatomically curved, or shaped like a chisel handle to facilitate the positioning. This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)348-9500customerservice@zimmerbiomet.com

Regulatory Flags#

DUNS number
129278169
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00887868561368VersaNail®2810-13-0372810130372023-09-07
00889024707061A.L.P.S.®2142-35-0072142350072026-05-11
00889024707078DRILL BIT2312002012312002012026-05-11
00889024707085DRILL BIT8290-29-0708290290702026-05-11
00880304410541FIBER OPTICS FOR RC RETRACTOR9085349085342019-06-11
00880304321946BIFURCATED FIBER OPTIC CABLE31-55550231-5555022017-07-28
008803044639124MM X 9FT. LIGHT CABLE9061179061172017-07-28
00889024707054CALIBRATED DRILL BIT2142-27-0702142270702026-04-27
00880304233102Biomet® Knee System1418721418722015-10-24
00880304233126Biomet® Knee System1418741418742015-10-24
00880304233140Biomet® Knee System1418761418762015-10-24
00880304233164Biomet® Knee System1418781418782015-10-24
00880304233171Biomet® Knee System1418801418802015-10-24
00880304233188Biomet® Knee System1418821418822015-10-24
00880304433403Vanguard® Knee System1841441841442015-10-24
00880304433410Vanguard® Knee System1841811841812015-10-24
00880304433564Vanguard® Knee System1842851842852015-10-24
00880304433984Vanguard® Knee System1842801842802015-10-24
00880304434356Vanguard® Knee System1842651842652015-10-24
00880304434363Vanguard® Knee System1842701842702015-10-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00840097535678Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535692Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535715Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535739Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535753Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535777Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535791Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535814Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535838Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535852Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535876Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097535890Veritas rTSARestor3d, Inc.PHX2026-06-03
00840097534978Veritas rTSARestor3d, Inc.PHX2026-06-02
00840097534985Veritas rTSARestor3d, Inc.PHX2026-06-02
B1132A2HI000100Shoulder Innovations InSet 95 Humeral StemShoulder Innovations, Inc.KWS2026-05-28
07613327603361REUNIONStryker GmbHKWS2024-10-01
07613327354331REUNIONStryker GmbHKWS2022-11-15
07613327354355REUNIONStryker GmbHKWS2022-11-15
07613327354805REUNIONStryker GmbHKWS2022-11-15
07613327354904REUNIONStryker GmbHKWS2022-11-15
07613327354935REUNIONStryker GmbHKWS2022-11-15
07613327354942REUNIONStryker GmbHKWS2022-11-15
07613327355024REUNIONStryker GmbHKWS2022-11-15
07613327355093REUNIONStryker GmbHKWS2022-11-15
07613327355109REUNIONStryker GmbHKWS2022-11-15
07613327355222REUNIONStryker GmbHKWS2022-11-15
07613327355246REUNIONStryker GmbHKWS2022-11-15
07613327355260REUNIONStryker GmbHKWS2022-11-15
07613327355291REUNIONStryker GmbHKWS2022-11-15
07613327355345REUNIONStryker GmbHKWS2022-11-15