ESSILOR RETINA 400

Primary DI
03615020000267
Brand
ESSILOR RETINA 400
Company
ESSILOR INTERNATIONAL
Model
RETINA 400
Device description
"Retina 400 is an electromedical system that allows for digitally retrieving, acquiring and processing of a retinal image, for use in ophthalmological diagnosis by medical specialists, and other uses inherent to the professional activity of other operators, optometrists and opticians, to the extent permitted by the laws and regulations for the exercise of their profession.An absolute new entry in the field for retinal imaging, the instrument allows for a direct, ""live"" monitoring on the computer screen, and capturing also in cases where the pupil diameter is extremely narrow. The instrument, with manual acquisition and electronically guided control, guarantees high precision and repeatability of the measurements."
Published
2016-09-23
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
HKICamera, Ophthalmic, Ac-Powered

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HKICamera, Ophthalmic, Ac-PoweredOphthalmic2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
03615020000267PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
03615020000267036150200002673615020000267

GMDN Terms#

Term, Definition table
TermDefinition
Ophthalmic fundus cameraAn electrically-powered optical device intended to be used to create digital colour photographic images/video of the ocular fundus (interior eye surface opposite the lens) through the pupil, to aid in diagnosing and monitoring retinal pathology; it may also be used for images/video of the anterior chamber. The image/video is typically transferred to a computer for display on its screen and/or for storage in a database. This device is also known as a retinal camera.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Handling Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature-40 Degrees Celsius70 Degrees Celsius
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius55 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
817-262-3801John.Anderson@essilorusa.com

Regulatory Flags#

DUNS number
277373213
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
03615020000397Digital C.R.PX817052026-04-09
03615020000014AKR 550AKR5502026-02-23
03615020000113CP 550CP5502026-02-23
03615020000441AKR 800AKR1JR2026-02-23
03615024000003Essilor StellestEmmetropia2025-10-16
03615024000027Essilor Stellestmyopic correction2025-10-16
03615024000034Essilor StellestMyopia+Astigmatism2025-10-16
03615020000458WAVE ANALYZER MEDICA 800WAM8002023-07-25
03615020000380WAVE ANALYZER MEDICA 700 PLUSWAM7002016-09-23
03615020000465ESSILOR RETINA 800RET1IN2020-04-02
03615020000489OCT500OCT2JT2020-03-23
03615020000038ALM500ALM5002023-10-03
03615020000120ALM700ALM7002023-10-03
03615020000236ALM800ALM8002023-10-03
03615020000670Vision-C 600VRS0012023-09-28
03615020000427Vision-R 800V010122023-09-11
03615020000663Vision-R 700V011122023-09-11
03615020000687Vision-S 700VS010122023-09-11
03615020000694Vision-R 800V010142023-09-11
03615020000724Vision-R 700V011142023-09-11

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
10857253006085Phoenix ICON GO Control BoxPhoenix ClinicalHKI2026-05-14
00857253006019ICON HandpiecePhoenix ClinicalHKI2026-04-03
00857253006033FA ModulePhoenix ClinicalHKI2026-04-03
00857253006071DiffuserPhoenix ClinicalHKI2026-04-03
00857253006101Phoenix ICON with Training KitPhoenix ClinicalHKI2026-04-03
00857253006118Phoenix ICON & FA Module with Training KitPhoenix ClinicalHKI2026-04-03
00857253006132Phoenix ICON GO with Training KitPhoenix ClinicalHKI2026-04-03
00857253006149Phoenix ICON GO & FA Module with Training Kit Phoenix ClinicalHKI2026-04-03
05713315011597RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011641RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011924RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011931RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011948RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011962RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
06430046261006Optomed Smartscope FAOptomed OyHKI2025-12-12
06430046260597Smartscope Pro full setOptomed OyHKI2025-11-13
06430046260689Smartscope Pro retinal setOptomed OyHKI2025-11-13
045601262691023D OPTICAL COHERENCE TOMOGRAPHY 3D OCT-1(Type:Maestro2)TOPCON CORPORATIONHKI2025-09-11
00860014304507OptainOptain Health, Inc.HKI2025-07-07
00860010658109Fundus PhotoFundus PhotoHKI2025-03-31
03664188000589ZEISSLUNEAU TECHNOLOGY OPERATIONSHKI2025-03-11
00860000249584Verily Numetric Retinal Camera VERILY LIFE SCIENCES LLCHKI2025-02-24
00852788008019NeolightNEOLIGHT LLCHKI2025-01-26
00852788008026NeolightNEOLIGHT LLCHKI2025-01-26
00852788008040NeolightNEOLIGHT LLCHKI2025-01-26
00852788008057NeolightNEOLIGHT LLCHKI2025-01-26
00852788008064NeolightNEOLIGHT LLCHKI2025-01-26
00852788008071NeolightNEOLIGHT LLCHKI2025-01-26
10852788008085NeolightNEOLIGHT LLCHKI2025-01-26
20852788008020NeolightNEOLIGHT LLCHKI2025-01-26