Focal One

GUDID 03661690000052

The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HIFU) to ablate prostate tissue. The Focal One system consists of the following main sub-assemblies: Focal One Control Module, Dynamic Focal Probe, and consumable Focalpak. HIFU is a unique process of delivering a large amount of heat energy to a confined space in a highly controlled manner. This energy heats the tissue to ablation levels while minimizing the effect on surrounding structures. The ultrasound energy is delivered via an endorectal probe, which includes an imaging system. The ultrasound waves propagate through the rectal wall and are focused on a portion of the prostate, generating intense heat and causing the ablation of tissue within the targeted area. The process is then repeated in a stepwise fashion to destroy the targeted tissues within the prostate. The apex, sphincter and rectum are preserved while prostate tissues are ablated.Imported diagnostic data can be fused with the real time ultrasound image in order to facilitate the targeting of the ablation volume.

EDAP-TMS FRANCE

Physical therapy ultrasound system
Primary Device ID03661690000052
NIH Device Record Keyf1211e35-f102-4f1b-a767-1201fda7c4a0
Commercial Distribution StatusIn Commercial Distribution
Brand NameFocal One
Version Model NumberTMS 234780
Company DUNS383113362
Company NameEDAP-TMS FRANCE
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usefalse
Lot Batchfalse
Serial Numbertrue
Manufacturing Datetrue
Expiration Datefalse
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Customer Support Contacts

Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com
Phone+33763346399
Emailagarin@edap-tms.com

Device Identifiers

Device Issuing AgencyDevice ID
GS103661690000052 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

PLPHigh Intensity Ultrasound System For Prostate Tissue Ablation

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusUpdate
Device Record StatusPublished
Public Version Number2
Public Version Date2020-04-16
Device Publish Date2018-06-11

Devices Manufactured by EDAP-TMS FRANCE

03661690000069 - Focalpak2023-09-21 The Focalpak is the single use kit of consumables to support a single patient procedure using the Focal One system which is a co
03661690000243 - FocalPak2021-03-12 The Focalpak is the single use kit of consumables to support a single patient procedure using the Focal One system which is a co
03661690000052 - Focal One2020-04-16The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HIFU) to ablate prostate tissue. The Focal One system consists of the following main sub-assemblies: Focal One Control Module, Dynamic Focal Probe, and consumable Focalpak. HIFU is a unique process of delivering a large amount of heat energy to a confined space in a highly controlled manner. This energy heats the tissue to ablation levels while minimizing the effect on surrounding structures. The ultrasound energy is delivered via an endorectal probe, which includes an imaging system. The ultrasound waves propagate through the rectal wall and are focused on a portion of the prostate, generating intense heat and causing the ablation of tissue within the targeted area. The process is then repeated in a stepwise fashion to destroy the targeted tissues within the prostate. The apex, sphincter and rectum are preserved while prostate tissues are ablated.Imported diagnostic data can be fused with the real time ultrasound image in order to facilitate the targeting of the ablation volume.
03661690000052 - Focal One2020-04-16 The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HI

Trademark Results [Focal One]

Mark Image

Registration | Serial
Company
Trademark
Application Date
FOCAL ONE
FOCAL ONE
78153657 not registered Dead/Abandoned
Novartis AG
2002-08-13
FOCAL ONE
FOCAL ONE
78149737 not registered Dead/Abandoned
Novartis AG
2002-08-01
FOCAL ONE
FOCAL ONE
78127571 2764216 Dead/Cancelled
Novartis AG
2002-05-09

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.