Olympus

Primary DI
04042761079129
Brand
Olympus
Company
OLYMPUS Winter & Ibe GmbH
Model
WA69300S
Catalog number
WA69300S
Device description
"Shaft ""HICURA"", 5 x 250, monopolar"
Published
2016-09-21
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K140624000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K140624000HICURA HAND INSTRUMENTSOlympus Winter & Ibe GmbH2014-12-10GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04042761079129PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04042761079129040427610791294042761079129

GMDN Terms#

Term, Definition table
TermDefinition
Orthopaedic implantation sleeve, reusableA hand-held tubular surgical device designed to be used during an orthopaedic implantation procedure to hold/grip an implant (e.g., an orthopaedic bone screw), facilitate the acceptance of an orthopaedic instrument (e.g., a screwdriver or a smaller diameter sleeve) through it, stabilize an instrument/implant coupling, and/or protect the surgeon's gloved hand or patient tissue. It is not primarily intended to place, angle, and guide a rotating surgical drill. It is typically made of high-grade stainless steel and/or synthetic materials and is available in various sizes and lengths. This is a reusable device.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)401-1086xx@xx.xx

Regulatory Flags#

DUNS number
316957240
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04042761082297OlympusWA03300AWA03300A2016-09-22
04042761082303OlympusWA03310AWA03310A2016-09-22
14042761083369OlympusWT645010WT6450102023-06-20
04042761083324OlympusWT806450WT8064502023-01-27
04042761081757OlympusWA97013AWA97013A2023-06-20
04042761083102OlympusWT2187002023-06-20
04042761083119OlympusWT2187052023-06-20
04042761083126OlympusWT2187112023-06-20
04042761083133OlympusWT2187202023-06-20
04042761083140OlympusWT6304002023-06-20
04042761083164OlympusWT6400212023-06-20
04042761083171OlympusWT645001WT6450012023-06-20
04042761083188OlympusWT645006WT6450062023-06-20
04042761083218OlympusWT645013WT6450132023-06-20
04042761083225OlympusWT645016WT6450162023-06-20
04042761083232OlympusWT645017WT6450172023-06-20
04042761083256OlympusWT645020WT6450202023-06-20
04042761083263OlympusWT645025WT6450252023-06-20
04042761083270OlympusWT645030WT6450302023-06-20
04042761083287OlympusWT645031WT6450312023-06-20

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00197998302718Solventum™Solventum US LLCGEI2026-09-25
00724995269586Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269951Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269968Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00190776432300MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432317MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432324MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432430MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432447MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432454MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776431457MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432041MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432195MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432201MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776431181MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431198MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431204MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431211MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431228MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431235MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431242MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431259MillenniumAvalign Technologies, Inc.GEI2026-09-21
10840113236852BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236890BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236937BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237040BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237064BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237101BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237118BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237132BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21