ENDOCAM

Primary DI
04055207013243
Brand
ENDOCAM
Company
Richard Wolf GmbH
Model
5525933
Catalog number
5525933
Device description
"LOGIC HD PENDUAL CAMERA HEAD CABLE 3M integrated lens, 1 chip, Adjustable: oscillating or straight, 2 camera-head buttons, Sensor size: 1/3"""
Published
2016-09-23
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
FETEndoscopic video imaging system/component, gastroenterology-urology

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FETEndoscopic Video Imaging System/Component, Gastroenterology-UrologyGastroenterology, Urology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04055207013243PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04055207013243040552070132434055207013243

GMDN Terms#

Term, Definition table
TermDefinition
Endoscope video cameraAn electro-optical device (e.g., a CCD) designed to be attached, either directly or with an adaptor, to a flexible or rigid endoscope to allow real-time viewing of the internal anatomy during an endoscopic surgical procedure and to obtain moving-picture documentation of endoscopic findings and procedures. The device is designed for transducing visual images as a sequence of electronic data following a pre-established standard; the images are usually displayed sequentially on the screen of a monitor as a video image. The device may include audio recording capabilities.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
Hydrogen Peroxide
Hydrogen Peroxide;Ethylene Oxide

Contacts#

Phone, Email table
PhoneEmail
+497043350info@richard-wolf.com

Regulatory Flags#

DUNS number
315304071
Device count
1
Serial number
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04055207011478NA8863758863.752026-05-19
04055207011539NA8913608913.602026-05-19
04055207054390NA417022284170.22282026-05-19
04055207048788NA484076448407642026-05-13
04055207008881NA8061168061.162016-09-23
04055207008898NA8061258061.252016-09-23
04055207008904NA8061358061.352016-09-23
04055207008911NA8062358062.352016-09-23
04055207012611NA40702534070.2532016-09-23
04055207013823NA80611638061.1632016-09-23
04055207013830NA80612538061.2532016-09-23
04055207013854NA80613538061.3532016-09-23
04055207013861NA80613568061.3562016-09-23
04055207013878NA80614538061.4532016-09-23
04055207013885NA80614568061.4562016-09-23
04055207013892NA80614578061.4572016-09-23
04055207013908NA80618538061.8532016-09-23
04055207013922NA80622518062.2512016-09-23
04055207013939NA80623518062.3512016-09-23
04055207013946NA80624518062.4512016-09-23

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
04547410480269FUJIFILMFUJIFILM CORPORATIONFET2026-05-22
00840432200063CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200117CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200308CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200315CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200322CystoView™Verathon Medical (Canada) ULCFET2026-05-15
04049047788553GimmiGimmi GmbHFET2026-03-04
04049047788577GimmiGimmi GmbHFET2026-03-04
04049047788584GimmiGimmi GmbHFET2026-03-04
06971176282399EviewZhuhai Pusen Medical Technology Co, LtdFET2026-01-22
06972520300677Endoscopic Video Image ProcessorGuangzhou Red Pine Medical Instrument Co., Ltd.FET2025-12-31
05391533810088ProVee Video Processing UnitPROVERUM LIMITEDFET2025-12-02
05391533810095ProVee Video Processing UnitPROVERUM LIMITEDFET2025-12-02
04953170445538OTV-S700 UPGRADE PACK IROLYMPUS MEDICAL SYSTEMS CORP.FET2025-11-21
04048551418123n.a.Karl Storz GmbH & Co. KGFET2025-08-11
04961333255801INSPIRAHOYA CORPORATIONFET2025-06-20
04961333255825INSPIRAHOYA CORPORATIONFET2025-06-20
04250480104200NASCHÖLLY FIBEROPTIC GmbHFET2025-06-11
04250480104262N/ASCHÖLLY FIBEROPTIC GmbHFET2025-06-11
04547410513790FUJIFILMFUJIFILM CORPORATIONFET2025-05-31
049531704302684K Camera HeadOLYMPUS MEDICAL SYSTEMS CORP.FET2025-04-17
04953170433313VISERA ELITE III VIDEO SYSTEM CENTEROLYMPUS MEDICAL SYSTEMS CORP.FET2025-04-17
04953170433412VISERA ELITE III LED LIGHT SOURCEOLYMPUS MEDICAL SYSTEMS CORP.FET2025-04-17
04953170445453OTV-S700 UPGRADE PACK 3DOLYMPUS MEDICAL SYSTEMS CORP.FET2025-04-17
04048551432259NAKarl Storz GmbH & Co. KGFET2025-03-27
04049047788539GimmiGimmi GmbHFET2025-03-20
04049047788546GimmiGimmi GmbHFET2025-03-20
04049047788560GimmiGimmi GmbHFET2025-03-20
06970462546214Single-use Biliary Pancreaticobiliary ScopeShenzhen HugeMed Medical Technical Development Co., Ltd.FET2025-02-28
06970462546221Single-use Biliary Pancreaticobiliary ScopeShenzhen HugeMed Medical Technical Development Co., Ltd.FET2025-02-28